-- -- Copyright(C) 2005 ALAXALA Networks Corporation. All Rights Reserved. -- -- AX2000R-MIB.my: Switching Router System information MIB file -- AX2000R DEFINITIONS ::= BEGIN IMPORTS enterprises, OBJECT-TYPE, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI RouterID, AreaID FROM RFC1253-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 ifIndex FROM RFC-1213; alaxala OBJECT IDENTIFIER ::= { enterprises 21839 } alaxalaProductId OBJECT IDENTIFIER ::= { alaxala 1 } axRouter OBJECT IDENTIFIER ::= { alaxalaProductId 1 } ax2000r OBJECT IDENTIFIER ::= { axRouter 4 }--temporary alaxalaMib OBJECT IDENTIFIER ::= { alaxala 2 } axrEx OBJECT IDENTIFIER ::= { alaxalaMib 1 } axrMib OBJECT IDENTIFIER ::= { axrEx 1 } ax2000rMib OBJECT IDENTIFIER ::= { axrEx 4 } --temporary -- device independent axrStats OBJECT IDENTIFIER ::= { axrMib 1 } axrPhysStats OBJECT IDENTIFIER ::= { axrStats 1 } axrAtmVcStats OBJECT IDENTIFIER ::= { axrStats 2 } axrSonetStats OBJECT IDENTIFIER ::= { axrStats 3 } axrIfStats OBJECT IDENTIFIER ::= { axrStats 4 } axrAtm25MStats OBJECT IDENTIFIER ::= { axrStats 5 } axrQoS OBJECT IDENTIFIER ::= { axrStats 6 } axrEtherTxQoS OBJECT IDENTIFIER ::= { axrQoS 1 } axrPPPTxQoS OBJECT IDENTIFIER ::= { axrQoS 2 } axrFRTxQoS OBJECT IDENTIFIER ::= { axrQoS 3 } axrEthShaper OBJECT IDENTIFIER ::= { axrQoS 4 } axrEthVll OBJECT IDENTIFIER ::= { axrQoS 6 } axrDHCP OBJECT IDENTIFIER ::= { axrStats 10 } axrOspf OBJECT IDENTIFIER ::= { axrMib 14 } axrOspfv3 OBJECT IDENTIFIER ::= { axrMib 15 } ax2000rRouter OBJECT IDENTIFIER ::= { ax2000rMib 1 } ax2000rSoftware OBJECT IDENTIFIER ::= { ax2000rRouter 2 } ax2000rSystemMsg OBJECT IDENTIFIER ::= { ax2000rRouter 3 } ax2000rSnmpAgent OBJECT IDENTIFIER ::= { ax2000rRouter 4 } ax2000rDevice OBJECT IDENTIFIER ::= { ax2000rMib 2 } ax2000rChassis OBJECT IDENTIFIER ::= { ax2000rDevice 1 } ax2000rRmBoard OBJECT IDENTIFIER ::= { ax2000rDevice 2 } ax2000rRpBoard OBJECT IDENTIFIER ::= { ax2000rDevice 3 } ax2000rNifBoard OBJECT IDENTIFIER ::= { ax2000rDevice 4 } ax2000rPhysLine OBJECT IDENTIFIER ::= { ax2000rDevice 5 } ax2000rInterface OBJECT IDENTIFIER ::= { ax2000rDevice 6 } -- AX2000R axrPhysStats group axrPhysStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrPhysStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing statistics for physical and time slots layer interface." ::= { axrPhysStats 1 } axrPhysStatsEntry OBJECT-TYPE SYNTAX AxrPhysStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the physical and time slots layer statistics for a particular interface." INDEX { axrPhysStatsIfIndex } ::= { axrPhysStatsTable 1 } AxrPhysStatsTableEntry ::= SEQUENCE { axrPhysStatsIfIndex INTEGER, axrPhysStatsIfDescr DisplayString, axrPhysStatsIfType INTEGER, axrPhysStatsInFCSs Counter, axrPhysStatsInAborts Counter, axrPhysStatsOverrun Counter, axrPhysStatsUnderrun Counter, axrPhysStatsInOddbits Counter, axrPhysStatsInShortfrms Counter, axrPhysStatsSendTimeout Counter } axrPhysStatsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object identifies the physical layer interface or the time slot layer interface for WAN." ::= { axrPhysStatsEntry 1 } axrPhysStatsIfDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the interface. Same as ifDescr (MIB II)." ::= { axrPhysStatsEntry 2 } axrPhysStatsIfType OBJECT-TYPE SYNTAX INTEGER { other(1), v24(2), v35(5), x21(6), bri(21), j1(31), j2(41), oc-3(101), oc-12(102), oc-48(103), e1(201), e3(202), t1(203), t3(204) } ACCESS read-only STATUS mandatory DESCRIPTION "The hardware type of physical interfaces." ::= { axrPhysStatsEntry 3 } axrPhysStatsInFCSs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of FCS error frames that received." ::= { axrPhysStatsEntry 4 } axrPhysStatsInAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of abort frames that received." ::= { axrPhysStatsEntry 5 } axrPhysStatsOverrun OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that overrun error occurred on receiving time." ::= { axrPhysStatsEntry 6 } axrPhysStatsUnderrun OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of that a transmission underrun errors occurred." ::= { axrPhysStatsEntry 7 } axrPhysStatsInOddbits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of odd bit frames that received." ::= { axrPhysStatsEntry 8 } axrPhysStatsInShortfrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of short frames that received." ::= { axrPhysStatsEntry 9 } axrPhysStatsSendTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times that a transmission timeout ocurred." ::= { axrPhysStatsEntry 10 } axrAtmVcStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrAtmVcStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing statistics for Virtual Channel Link (VCL)." ::= { axrAtmVcStats 1 } axrAtmVcStatsEntry OBJECT-TYPE SYNTAX AxrAtmVcStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the VCL statistics for a particular ATM interface." INDEX { axrAtmVcStatsIfIndex, axrAtmVcStatsVclVpi, axrAtmVcStatsVclVci } ::= { axrAtmVcStatsTable 1 } AxrAtmVcStatsTableEntry ::= SEQUENCE { axrAtmVcStatsIfIndex INTEGER, axrAtmVcStatsVclVpi INTEGER, axrAtmVcStatsVclVci INTEGER, axrAtmVcStatsInCells Counter, axrAtmVcStatsInDiscards Counter, axrAtmVcStatsOutCells Counter, axrAtmVcStatsOutDiscards Counter, axrAtmVcStatsInPkts Counter, axrAtmVcStatsInDiscPkts Counter, axrAtmVcStatsInOctets Counter, axrAtmVcStatsOutPkts Counter, axrAtmVcStatsOutDiscPkts Counter, axrAtmVcStatsOutOctets Counter, axrAtmVcStatsIfDescr DisplayString, axrAtmVcStatsIfSpeed INTEGER } axrAtmVcStatsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object identifies for an ATM interface. This object has the same value as the ifIndex object." ::= { axrAtmVcStatsEntry 1 } axrAtmVcStatsVclVpi OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The VPI value of the VCL." ::= { axrAtmVcStatsEntry 2 } axrAtmVcStatsVclVci OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The VCI value of the VCL." ::= { axrAtmVcStatsEntry 3 } axrAtmVcStatsInCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells that received on this VC." ::= { axrAtmVcStatsEntry 4 } axrAtmVcStatsInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells which have been dropped by the VCL due to lack of output queue." ::= { axrAtmVcStatsEntry 5 } axrAtmVcStatsOutCells OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells that transmitted on this VCL." ::= { axrAtmVcStatsEntry 6 } axrAtmVcStatsOutDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of cells which have been dropped by the VCL due to input queue." ::= { axrAtmVcStatsEntry 7 } axrAtmVcStatsInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets received on this VCL." ::= { axrAtmVcStatsEntry 8 } axrAtmVcStatsInDiscPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets which were chosen to be discarded." ::= { axrAtmVcStatsEntry 9 } axrAtmVcStatsInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets received on this VCL." ::= { axrAtmVcStatsEntry 10 } axrAtmVcStatsOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of this VCL." ::= { axrAtmVcStatsEntry 11 } axrAtmVcStatsOutDiscPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded." ::= { axrAtmVcStatsEntry 12 } axrAtmVcStatsOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of this VCL." ::= { axrAtmVcStatsEntry 13 } axrAtmVcStatsIfDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Interface name of this VC, and description." ::= { axrAtmVcStatsEntry 14 } axrAtmVcStatsIfSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum transmitting bandwidth of VCL." ::= { axrAtmVcStatsEntry 15 } -- ATM Interface Configuration Extension Table axrAtmInterfaceExtTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrAtmInterfaceExtTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains ATM interface configuration and monitoring information not defined in the atmInterfaceConfTable from the ATM-MIB. This includes the type of connection setup procedures, ILMI information, and information on the VPI/VCI range." REFERENCE "Tesink, K., Editor, Definitions of Managed Objects for ATM Management, RFC 2515, Bell Communications Research, February, 1999." ::= { axrAtmVcStats 2 } axrAtmInterfaceExtEntry OBJECT-TYPE SYNTAX AxrAtmInterfaceExtTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry extends the atmInterfaceConfEntry defined in the ATM- MIB. Each entry corresponds to an ATM interface." REFERENCE "Tesink, K., Editor, Definitions of Managed Objects for ATM Management, RFC 2515, Bell Communications Research, February, 1999." INDEX { axrAtmIntfPVcIfIndex } ::= { axrAtmInterfaceExtTable 1 } AxrAtmInterfaceExtTableEntry ::= SEQUENCE { axrAtmIntfPVcIfIndex INTEGER, axrAtmIntfPVcFailures Counter, axrAtmIntfCurrentlyFailingPVcls Gauge, axrAtmIntfPVcFailuresTrapEnable INTEGER, axrAtmIntfPVcTrapInterval INTEGER } axrAtmIntfPVcIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object identifies for an ATM interface. This object has the same value as the ifIndex object." ::= { axrAtmInterfaceExtEntry 1 } axrAtmIntfPVcFailures OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the operational status of a PVPL or PVCL on this interface has gone down." ::= { axrAtmInterfaceExtEntry 2 } axrAtmIntfCurrentlyFailingPVcls OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The current number of VCLs on this interface for which there is an active row." ::= { axrAtmInterfaceExtEntry 3 } axrAtmIntfPVcFailuresTrapEnable OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Allows the generation of traps in response to PVCL or PVPL failures on this interface." DEFVAL { false } ::= { axrAtmInterfaceExtEntry 4 } axrAtmIntfPVcTrapInterval OBJECT-TYPE SYNTAX INTEGER (1..3600) ACCESS read-only STATUS mandatory DESCRIPTION "The minimum interval between the sending of axrAtmPVcTrap notifications for this interface." DEFVAL { 30 } ::= { axrAtmInterfaceExtEntry 5 } -- Currently Failing PVCL Table axrAtmPVcFailingTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrAtmPVcFailingTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing statistics for Virtual Channel Link (VCL)." ::= { axrAtmVcStats 3 } axrAtmPVcFailingEntry OBJECT-TYPE SYNTAX AxrAtmPVcFailingTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the VCL statistics for a particular ATM interface." INDEX { axrAtmPVcFailingIfIndex, axrAtmPVcFailingVclVpi, axrAtmPVcFailingVclVci } ::= { axrAtmPVcFailingTable 1 } AxrAtmPVcFailingTableEntry ::= SEQUENCE { axrAtmPVcFailingIfIndex INTEGER, axrAtmPVcFailingVclVpi INTEGER, axrAtmPVcFailingVclVci INTEGER, axrAtmPVcFailingCurrentlyTimeStamp TimeStamp, axrAtmPVcFailingPreviouslyTimeStamp TimeStamp } axrAtmPVcFailingIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object identifies for an ATM interface. This object has the same value as the ifIndex object." ::= { axrAtmPVcFailingEntry 1 } axrAtmPVcFailingVclVpi OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The VPI value of the VCL." ::= { axrAtmPVcFailingEntry 2 } axrAtmPVcFailingVclVci OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The VCI value of the VCL." ::= { axrAtmPVcFailingEntry 3 } axrAtmPVcFailingCurrentlyTimeStamp OBJECT-TYPE SYNTAX TimeStamp ACCESS read-only STATUS mandatory DESCRIPTION "The time at which this PVCL began to fail currently." ::= { axrAtmPVcFailingEntry 4 } axrAtmPVcFailingPreviouslyTimeStamp OBJECT-TYPE SYNTAX TimeStamp ACCESS read-only STATUS mandatory DESCRIPTION "The time at which this PVCL began to fail previously." ::= { axrAtmPVcFailingEntry 5 } axrSonetSectionStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrSonetSectionStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing SONET section statistics for sonet interfaces." ::= { axrSonetStats 1 } axrSonetSectionStatsEntry OBJECT-TYPE SYNTAX AxrSonetSectionStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing SONET section statistics for sonet interfaces." INDEX { axrSonetSectionStatsIfIndex } ::= { axrSonetSectionStatsTable 1 } AxrSonetSectionStatsTableEntry ::= SEQUENCE { axrSonetSectionStatsIfIndex INTEGER, axrSonetSectionStatsLOS Counter, axrSonetSectionStatsLOF Counter, axrSonetSectionStatsOOF Counter, axrSonetSectionStatsBIP8 Counter } axrSonetSectionStatsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object identifies for a SONET interface. This object has the same value as the ifIndex object." ::= { axrSonetSectionStatsEntry 1 } axrSonetSectionStatsLOS OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times LOS(Loss Of Signal)." ::= { axrSonetSectionStatsEntry 2 } axrSonetSectionStatsLOF OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times LOF(Loss Of Frame).An LOF defect is declared when OOF(Out of Frame) defect persists for a period of 3 milliseconds." ::= { axrSonetSectionStatsEntry 3 } axrSonetSectionStatsOOF OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object count when out of synchronous." ::= { axrSonetSectionStatsEntry 4 } axrSonetSectionStatsBIP8 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times S-BIP8(Bit Interleaved Parity 8) Error." ::= { axrSonetSectionStatsEntry 5 } axrSonetLineStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrSonetLineStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing line statistics for sonet interfaces." ::= { axrSonetStats 2 } axrSonetLineStatsEntry OBJECT-TYPE SYNTAX AxrSonetLineStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing line statistics for sonet interfaces." INDEX { axrSonetLineStatsIfIndex } ::= { axrSonetLineStatsTable 1 } AxrSonetLineStatsTableEntry ::= SEQUENCE { axrSonetLineStatsIfIndex INTEGER, axrSonetLineStatsAIS Counter, axrSonetLineStatsRDI Counter, axrSonetLineStatsBIP24 Counter, axrSonetLineStatsFEBE Counter } axrSonetLineStatsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of this object identifies for a sonet interface. This object has the same value as the ifIndex object." ::= { axrSonetLineStatsEntry 1 } axrSonetLineStatsAIS OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Line L-AIS(Alarm Indication Signal) that received at sonet interface." ::= { axrSonetLineStatsEntry 2 } axrSonetLineStatsRDI OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of L-RDI(Remote Defect Indication) errors that received on the sonet interface." ::= { axrSonetLineStatsEntry 3 } axrSonetLineStatsBIP24 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of L-BIP24(Bit Interleaved Parity 24) errors on the sonet interface." ::= { axrSonetLineStatsEntry 4 } axrSonetLineStatsFEBE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of L-FEBE(Line Far End Block Error) that received on the sonet interface." ::= { axrSonetLineStatsEntry 5 } axrSonetPathStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrSonetPathStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Path statistics for SONET interface." ::= { axrSonetStats 3 } axrSonetPathStatsEntry OBJECT-TYPE SYNTAX AxrSonetPathStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Path statistics for SONET interface." INDEX { axrSonetPathStatsIfIndex } ::= { axrSonetPathStatsTable 1 } AxrSonetPathStatsTableEntry ::= SEQUENCE { axrSonetPathStatsIfIndex INTEGER, axrSonetPathStatsLOP Counter, axrSonetPathStatsAIS Counter, axrSonetPathStatsRDI Counter, axrSonetPathStatsBIP8 Counter, axrSonetPathStatsFEBE Counter } axrSonetPathStatsIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The IfIndex value of interface that use SONET." ::= { axrSonetPathStatsEntry 1 } axrSonetPathStatsLOP OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of LOP(Loss Of Pointer) errors that received on the sonet interface." ::= { axrSonetPathStatsEntry 2 } axrSonetPathStatsAIS OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of P-AIS(Alarm Indication Signal) that received on the sonet interface." ::= { axrSonetPathStatsEntry 3 } axrSonetPathStatsRDI OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of P-RDI(Path Remote Defect Indication) that received on the sonet interface." ::= { axrSonetPathStatsEntry 4 } axrSonetPathStatsBIP8 OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of P-BIP8(Bit Interleaved Parity 8) errors that received on the sonet interface." ::= { axrSonetPathStatsEntry 5 } axrSonetPathStatsFEBE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of P-FEBE(Far End Block Error) errors that received on the sonet interface." ::= { axrSonetPathStatsEntry 6 } axrIfStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrIfStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing extension statistics for more than 100,000,000 bps interface." ::= { axrIfStats 1 } axrIfStatsEntry OBJECT-TYPE SYNTAX AxrIfStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing extension statistics for interface." INDEX { axrIfStatsIndex } ::= { axrIfStatsTable 1 } AxrIfStatsTableEntry ::= SEQUENCE { axrIfStatsIndex INTEGER, axrIfStatsName DisplayString, axrIfStatsInMegaOctets Counter, axrIfStatsInUcastMegaPkts Counter, axrIfStatsInMulticastMegaPkts Counter, axrIfStatsInBroadcastMegaPkts Counter, axrIfStatsOutMegaOctets Counter, axrIfStatsOutUcastMegaPkts Counter, axrIfStatsOutMulticastMegaPkts Counter, axrIfStatsOutBroadcastMegaPkts Counter, axrIfStatsHighSpeed Counter } axrIfStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "This object value is same as Ifindex which interface index of a system." ::= { axrIfStatsEntry 1 } axrIfStatsName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Interfaces name. Same as ifDescr." ::= { axrIfStatsEntry 2 } axrIfStatsInMegaOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of octets that received on the interface. This value is displayed in mega-octets(M). Value of 0 through 999,999 are rounded down." ::= { axrIfStatsEntry 3 } axrIfStatsInUcastMegaPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of subnetwork-unicast packets that received on the interface. This value is displayed in mega-packets(M).Value of 0 through 999,999 are rounded down." ::= { axrIfStatsEntry 4 } axrIfStatsInMulticastMegaPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of multicast mega-packets that received on the interface. this value is displayed in mega-packets(M).Value of 0 through 999,999 are rounded down." ::= { axrIfStatsEntry 5 } axrIfStatsInBroadcastMegaPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of non-unicast packets delivered to a higher-layer protocol. The value is displayed in mega-packets (M). Value of 0 through 999,999 are rounded down. " ::= { axrIfStatsEntry 6 } axrIfStatsOutMegaOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface. The value is displayed in mega-octets(M). Value of 0 through 999,999 are rounded down." ::= { axrIfStatsEntry 7 } axrIfStatsOutUcastMegaPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address.The value is displayed in mega packets(M). Value of 0 through 999,999 are rounded down." ::= { axrIfStatsEntry 8 } axrIfStatsOutMulticastMegaPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of multicast packets that transmitted on the interface. This value is displayed in mega-packets(M). Value of 0 through 999,999 are rounded down." ::= { axrIfStatsEntry 9 } axrIfStatsOutBroadcastMegaPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of broadcast packets that transmitted on the interface. This value is displayed in mega-packets(M). Value of 0 through 999,999 are rounded down. " ::= { axrIfStatsEntry 10 } axrIfStatsHighSpeed OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A circuit speed.This value is displayed in mega-bps[Mbps]. Round off the 1,000,000bps. " ::= { axrIfStatsEntry 11 } -- axrAtm25MStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrAtm25MStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Statistical information table on 25 Mega ATM interface." ::= { axrAtm25MStats 1 } axrAtm25MStatsEntry OBJECT-TYPE SYNTAX AxrAtm25MStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing error statistics for a particular 25 Mega ATM interface." INDEX { axrAtm25MStatsIndex } ::= { axrAtm25MStatsTable 1 } AxrAtm25MStatsTableEntry ::= SEQUENCE { axrAtm25MStatsIndex INTEGER, axrAtm25MStSymbolErr Counter, axrAtm25MStLOS Counter } axrAtm25MStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "A ifIndex value of 25 Mega ATM interface." ::= { axrAtm25MStatsEntry 1 } axrAtm25MStSymbolErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times symbol error." ::= { axrAtm25MStatsEntry 2 } axrAtm25MStLOS OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of times LOS(Loss Of Signal)." ::= { axrAtm25MStatsEntry 3 } -- QoS interface statistics Variables axrEtherTxQoSStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEtherTxQoSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of QoS statistics kept for a particular Ethernet interface." ::= { axrEtherTxQoS 1 } axrEtherTxQoSStatsEntry OBJECT-TYPE SYNTAX AxrEtherTxQoSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing QoS statistics for a particular Ethernet interface." INDEX { axrEtherTxQoSStatsIndex } ::= { axrEtherTxQoSStatsTable 1 } AxrEtherTxQoSStatsEntry ::= SEQUENCE { axrEtherTxQoSStatsIndex INTEGER, axrEtherTxQoSStatsMaxQnum INTEGER, axrEtherTxQoSStatsLimitQlen INTEGER, axrEtherTxQoSStatsTotalOutFrames Counter, axrEtherTxQoSStatsTotalOutBytesHigh Counter, axrEtherTxQoSStatsTotalOutBytesLow Counter, axrEtherTxQoSStatsTotalDiscardFrames Counter } axrEtherTxQoSStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrEtherTxQoSStatsEntry 1 } axrEtherTxQoSStatsMaxQnum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max length of queue for an ethernet interface." ::= { axrEtherTxQoSStatsEntry 2 } axrEtherTxQoSStatsLimitQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The limit length of outband queue for an ethernet interface." ::= { axrEtherTxQoSStatsEntry 3 } axrEtherTxQoSStatsTotalOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the interface." ::= { axrEtherTxQoSStatsEntry 4 } axrEtherTxQoSStatsTotalOutBytesHigh OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface." ::= { axrEtherTxQoSStatsEntry 5 } axrEtherTxQoSStatsTotalOutBytesLow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface." ::= { axrEtherTxQoSStatsEntry 6 } axrEtherTxQoSStatsTotalDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded ." ::= { axrEtherTxQoSStatsEntry 7 } axrEtherTxQoSStatsQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEtherTxQoSStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of priority queue statistics." ::= { axrEtherTxQoS 2 } axrEtherTxQoSStatsQueueEntry OBJECT-TYPE SYNTAX AxrEtherTxQoSStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A entry of priority queue statistics." INDEX { axrEtherTxQoSStatsQueueIndex , axrEtherTxQoSStatsQueueQueIndex } ::= { axrEtherTxQoSStatsQueueTable 1 } AxrEtherTxQoSStatsQueueEntry ::= SEQUENCE { axrEtherTxQoSStatsQueueIndex INTEGER, axrEtherTxQoSStatsQueueQueIndex INTEGER, axrEtherTxQoSStatsQueueQlen INTEGER, axrEtherTxQoSStatsQueueMaxQlen INTEGER } axrEtherTxQoSStatsQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrEtherTxQoSStatsQueueEntry 1 } axrEtherTxQoSStatsQueueQueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies the particular queue.Its value ranges between 1 and the value of axrEtherTxQoSStatsMaxQnum." ::= { axrEtherTxQoSStatsQueueEntry 2 } axrEtherTxQoSStatsQueueQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A length of outbound priority queue for a interface." ::= { axrEtherTxQoSStatsQueueEntry 3 } axrEtherTxQoSStatsQueueMaxQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max length of outband priority queue for a interface since system was up." ::= { axrEtherTxQoSStatsQueueEntry 4 } axrPPPTxQoSStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrPPPTxQoSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of QoS statistics kept for a particular PPP interface." ::= { axrPPPTxQoS 1 } axrPPPTxQoSStatsEntry OBJECT-TYPE SYNTAX AxrPPPTxQoSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing QoS statistics for a particular PPP interface." INDEX { axrPPPTxQoSStatsIndex } ::= { axrPPPTxQoSStatsTable 1 } AxrPPPTxQoSStatsEntry ::= SEQUENCE { axrPPPTxQoSStatsIndex INTEGER, axrPPPTxQoSStatsMaxQnum INTEGER, axrPPPTxQoSStatsLimitQlen INTEGER, axrPPPTxQoSStatsTotalOutFrames Counter, axrPPPTxQoSStatsTotalOutBytesHigh Counter, axrPPPTxQoSStatsTotalOutBytesLow Counter, axrPPPTxQoSStatsTotalDiscardFrames Counter } axrPPPTxQoSStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrPPPTxQoSStatsEntry 1 } axrPPPTxQoSStatsMaxQnum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max length of queue for a PPP interface." ::= { axrPPPTxQoSStatsEntry 2 } axrPPPTxQoSStatsLimitQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The limit length of outband queue for a PPP interface." ::= { axrPPPTxQoSStatsEntry 3 } axrPPPTxQoSStatsTotalOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the PPP interface." ::= { axrPPPTxQoSStatsEntry 4 } axrPPPTxQoSStatsTotalOutBytesHigh OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the PPP interface." ::= { axrPPPTxQoSStatsEntry 5 } axrPPPTxQoSStatsTotalOutBytesLow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the PPP interface." ::= { axrPPPTxQoSStatsEntry 6 } axrPPPTxQoSStatsTotalDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded ." ::= { axrPPPTxQoSStatsEntry 7 } axrPPPTxQoSStatsQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrPPPTxQoSStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of outbound priority queue statistics for a PPP interface." ::= { axrPPPTxQoS 2 } axrPPPTxQoSStatsQueueEntry OBJECT-TYPE SYNTAX AxrPPPTxQoSStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A entry of outbound priority queue statistics. for a PPP interface." INDEX { axrPPPTxQoSStatsQueueIndex, axrPPPTxQoSStatsQueueQueIndex } ::= { axrPPPTxQoSStatsQueueTable 1 } AxrPPPTxQoSStatsQueueEntry ::= SEQUENCE { axrPPPTxQoSStatsQueueIndex INTEGER, axrPPPTxQoSStatsQueueQueIndex INTEGER, axrPPPTxQoSStatsQueueQlen INTEGER, axrPPPTxQoSStatsQueueMaxQlen INTEGER, axrPPPTxQoSStatsQueueOutFrames Counter, axrPPPTxQoSStatsQueueOutBytesHigh Counter, axrPPPTxQoSStatsQueueOutBytesLow Counter, axrPPPTxQoSStatsQueueDiscardFrames Counter } axrPPPTxQoSStatsQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrPPPTxQoSStatsQueueEntry 1 } axrPPPTxQoSStatsQueueQueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies the particular queue.Its value ranges between 1 and the value of axrPPPTxQoSStatsMaxQnum." ::= { axrPPPTxQoSStatsQueueEntry 2 } axrPPPTxQoSStatsQueueQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A length of outbound priority queue for a PPP interface." ::= { axrPPPTxQoSStatsQueueEntry 3 } axrPPPTxQoSStatsQueueMaxQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max length of outband priority queue for a interface since system was up." ::= { axrPPPTxQoSStatsQueueEntry 4 } axrPPPTxQoSStatsQueueOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the PPP priority queue interface." ::= { axrPPPTxQoSStatsQueueEntry 5 } axrPPPTxQoSStatsQueueOutBytesHigh OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the PPP priority queue interface." ::= { axrPPPTxQoSStatsQueueEntry 6 } axrPPPTxQoSStatsQueueOutBytesLow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the PPP priority queue interface." ::= { axrPPPTxQoSStatsQueueEntry 7 } axrPPPTxQoSStatsQueueDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded at PPP priority queue interface." ::= { axrPPPTxQoSStatsQueueEntry 8 } axrFRTxQoSStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrFRTxQoSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of QoS statistics kept for a particular Frame Relay interface." ::= { axrFRTxQoS 1 } axrFRTxQoSStatsEntry OBJECT-TYPE SYNTAX AxrFRTxQoSStatsEntry --SHIMO EDIT ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing QoS statistics for a particular Frame Relay interface." INDEX { axrFRTxQoSStatsIndex } ::= { axrFRTxQoSStatsTable 1 } AxrFRTxQoSStatsEntry ::= SEQUENCE { axrFRTxQoSStatsIndex INTEGER, axrFRTxQoSStatsMaxQnum INTEGER, axrFRTxQoSStatsLimitQlen INTEGER, axrFRTxQoSStatsTotalOutFrames Counter, axrFRTxQoSStatsTotalOutBytesHigh Counter, axrFRTxQoSStatsTotalOutBytesLow Counter, axrFRTxQoSStatsTotalDiscardFrames Counter } axrFRTxQoSStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrFRTxQoSStatsEntry 1 } axrFRTxQoSStatsMaxQnum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max length of queue for a Frame Relay interface." ::= { axrFRTxQoSStatsEntry 2 } axrFRTxQoSStatsLimitQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The limit length of outband queue for a Frame Relay interface." ::= { axrFRTxQoSStatsEntry 3 } axrFRTxQoSStatsTotalOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the Frame Relay interface." ::= { axrFRTxQoSStatsEntry 4 } axrFRTxQoSStatsTotalOutBytesHigh OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the PFrame Relay interface." ::= { axrFRTxQoSStatsEntry 5 } axrFRTxQoSStatsTotalOutBytesLow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the PFrame Relay interface." ::= { axrFRTxQoSStatsEntry 6 } axrFRTxQoSStatsTotalDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded ." ::= { axrFRTxQoSStatsEntry 7 } axrFRTxQoSStatsQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrFRTxQoSStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of outbound priority queue statistics for a Frame Relay interface." ::= { axrFRTxQoS 2 } axrFRTxQoSStatsQueueEntry OBJECT-TYPE SYNTAX AxrFRTxQoSStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A entry of outbound priority queue statistics. for a Farme Relay interface." INDEX { axrFRTxQoSStatsQueueIndex, axrFRTxQoSStatsQueueQueIndex} ::= { axrFRTxQoSStatsQueueTable 1 } AxrFRTxQoSStatsQueueEntry ::= SEQUENCE { axrFRTxQoSStatsQueueIndex INTEGER, axrFRTxQoSStatsQueueQueIndex INTEGER, axrFRTxQoSStatsQueueQlen INTEGER, axrFRTxQoSStatsQueueMaxQlen INTEGER, axrFRTxQoSStatsQueueOutFrames Counter, axrFRTxQoSStatsQueueOutBytesHigh Counter, axrFRTxQoSStatsQueueOutBytesLow Counter, axrFRTxQoSStatsQueueDiscardFrames Counter } axrFRTxQoSStatsQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrFRTxQoSStatsQueueEntry 1 } axrFRTxQoSStatsQueueQueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies the particular queue.Its value ranges between 1 and the value of axrFRTxQoSStatsMaxQnum" ::= { axrFRTxQoSStatsQueueEntry 2 } axrFRTxQoSStatsQueueQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A length of outbound priority queue for a Frame Relay interface." ::= { axrFRTxQoSStatsQueueEntry 3 } axrFRTxQoSStatsQueueMaxQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max length of outband priority queue for a Frame Relay interface since system was up." ::= { axrFRTxQoSStatsQueueEntry 4 } axrFRTxQoSStatsQueueOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the Frame Relay priority queue interface." ::= { axrFRTxQoSStatsQueueEntry 5 } axrFRTxQoSStatsQueueOutBytesHigh OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the Frame Relay priority queue interface." ::= { axrFRTxQoSStatsQueueEntry 6 } axrFRTxQoSStatsQueueOutBytesLow OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the Frame Relay interface." ::= { axrFRTxQoSStatsQueueEntry 7 } axrFRTxQoSStatsQueueDiscardFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded ." ::= { axrFRTxQoSStatsQueueEntry 8 } axrEthShaperStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEthShaperStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of Shaper statistics kept for a particular Ethernet Shaper interface." ::= { axrEthShaper 1 } axrEthShaperStatsEntry OBJECT-TYPE SYNTAX AxrEthShaperStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Shaper statistics for a particular Ethernet Shaper interface." INDEX { axrEthShaperStatsIndex } ::= { axrEthShaperStatsTable 1 } AxrEthShaperStatsEntry ::= SEQUENCE { axrEthShaperStatsIndex INTEGER, axrEthShaperStatsTotalOutFrames Counter64, axrEthShaperStatsTotalOutBytes Counter64, axrEthShaperStatsTotalDiscardFrames Counter64, axrEthShaperStatsTotalDiscardBytes Counter64 } axrEthShaperStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrEthShaperStatsEntry 1 } axrEthShaperStatsTotalOutFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the interface." ::= { axrEthShaperStatsEntry 2 } axrEthShaperStatsTotalOutBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface." ::= { axrEthShaperStatsEntry 3 } axrEthShaperStatsTotalDiscardFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of outbound packets which were chosen to be discarded." ::= { axrEthShaperStatsEntry 4 } axrEthShaperStatsTotalDiscardBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of outbound octets which were chosen to be discarded." ::= { axrEthShaperStatsEntry 5 } axrEthShaperStatsQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEthShaperStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of priority queue statistics." ::= { axrEthShaper 2 } axrEthShaperStatsQueueEntry OBJECT-TYPE SYNTAX AxrEthShaperStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A entry of priority queue statistics." INDEX { axrEthShaperStatsQueueIndex, axrEthShaperStatsQueueQueIndex } ::= { axrEthShaperStatsQueueTable 1 } AxrEthShaperStatsQueueEntry ::= SEQUENCE { axrEthShaperStatsQueueIndex INTEGER, axrEthShaperStatsQueueQueIndex INTEGER, axrEthShaperStatsQueueOutFrames Counter64, axrEthShaperStatsQueueOutBytes Counter64, axrEthShaperStatsQueueDiscardFrames Counter64, axrEthShaperStatsQueueDiscardBytes Counter64 } axrEthShaperStatsQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrEthShaperStatsQueueEntry 1 } axrEthShaperStatsQueueQueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies the particular queue. Its value ranges between 1 and 4." ::= { axrEthShaperStatsQueueEntry 2 } axrEthShaperStatsQueueOutFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets transmitted out of the priority queue interface." ::= { axrEthShaperStatsQueueEntry 3 } axrEthShaperStatsQueueOutBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets transmitted out of the priority queue interface." ::= { axrEthShaperStatsQueueEntry 4 } axrEthShaperStatsQueueDiscardFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets which were chosen to be discarded." ::= { axrEthShaperStatsQueueEntry 5 } axrEthShaperStatsQueueDiscardBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets which were chosen to be discarded." ::= { axrEthShaperStatsQueueEntry 6 } axrEthShaperStatsFlowOtherFrmTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEthShaperStatsFlowOtherFrmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of Shaper other Frame statistics kept for a particular Ethernet Shaper interface." ::= { axrEthShaper 3 } axrEthShaperStatsFlowOtherFrmEntry OBJECT-TYPE SYNTAX AxrEthShaperStatsFlowOtherFrmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Shaper other Frame statistics for a particular Ethernet Shaper interface." INDEX { axrEthShaperStatsFlowOtherFrmNifIndex, axrEthShaperStatsFlowOtherFrmLineIndex } ::= { axrEthShaperStatsFlowOtherFrmTable 1 } AxrEthShaperStatsFlowOtherFrmEntry ::= SEQUENCE { axrEthShaperStatsFlowOtherFrmNifIndex INTEGER, axrEthShaperStatsFlowOtherFrmLineIndex INTEGER, axrEthShaperStatsFlowOtherFrmOutFrames Counter64, axrEthShaperStatsFlowOtherFrmOutBytes Counter64, axrEthShaperStatsFlowOtherFrmDiscardFrames Counter64, axrEthShaperStatsFlowOtherFrmDiscardBytes Counter64 } axrEthShaperStatsFlowOtherFrmNifIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of NIF.Its value ranges between 1 and the value of ax2000rNifBoardNumber." ::= { axrEthShaperStatsFlowOtherFrmEntry 1 } axrEthShaperStatsFlowOtherFrmLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of Physical Line.Its value ranges between 1 and the value of ax2000rNifPhysLineNumber." ::= { axrEthShaperStatsFlowOtherFrmEntry 2 } axrEthShaperStatsFlowOtherFrmOutFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted outside of a target for control out of the NIF." ::= { axrEthShaperStatsFlowOtherFrmEntry 3 } axrEthShaperStatsFlowOtherFrmOutBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted outside of a target for control out of the NIF." ::= { axrEthShaperStatsFlowOtherFrmEntry 4 } axrEthShaperStatsFlowOtherFrmDiscardFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of outbound packets outside of a target for control which were chosen to be discarded." ::= { axrEthShaperStatsFlowOtherFrmEntry 5 } axrEthShaperStatsFlowOtherFrmDiscardBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of outbound octets outside of a target for control which were chosen to be discarded." ::= { axrEthShaperStatsFlowOtherFrmEntry 6 } axrEthVllStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEthVllStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of Shaper statistics kept for a particular Ethernet Vll interface." ::= { axrEthVll 1 } axrEthVllStatsEntry OBJECT-TYPE SYNTAX AxrEthVllStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing Shaper statistics for a particular Ethernet Vll interface." INDEX { axrEthVllStatsIndex } ::= { axrEthVllStatsTable 1 } AxrEthVllStatsEntry ::= SEQUENCE { axrEthVllStatsIndex INTEGER, axrEthVllStatsTotalOutFrames Counter64, axrEthVllStatsTotalOutBytes Counter64, axrEthVllStatsTotalDiscardFrames Counter64, axrEthVllStatsTotalDiscardBytes Counter64 } axrEthVllStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrEthVllStatsEntry 1 } axrEthVllStatsTotalOutFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the interface." ::= { axrEthVllStatsEntry 2 } axrEthVllStatsTotalOutBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface." ::= { axrEthVllStatsEntry 3 } axrEthVllStatsTotalDiscardFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of outbound packets which were chosen to be discarded." ::= { axrEthVllStatsEntry 4 } axrEthVllStatsTotalDiscardBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of outbound octets which were chosen to be discarded." ::= { axrEthVllStatsEntry 5 } axrEthVllStatsQueueTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrEthVllStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A collection of priority queue statistics." ::= { axrEthVll 2 } axrEthVllStatsQueueEntry OBJECT-TYPE SYNTAX AxrEthVllStatsQueueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { axrEthVllStatsQueueIndex, axrEthVllStatsQueueQueIndex} ::= { axrEthVllStatsQueueTable 1 } AxrEthVllStatsQueueEntry ::= SEQUENCE { axrEthVllStatsQueueIndex INTEGER, axrEthVllStatsQueueQueIndex INTEGER, axrEthVllStatsQueuelimitQlen INTEGER, axrEthVllStatsQueueQlen INTEGER, axrEthVllStatsQueueMaxQlen INTEGER, axrEthVllStatsQueueOutFrames Counter64, axrEthVllStatsQueueOutBytes Counter64, axrEthVllStatsQueueDiscardFrames Counter64, axrEthVllStatsQueueDiscardBytes Counter64 } axrEthVllStatsQueueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Identified by a particular value of this index is same value of ifIndex.Its value ranges between 1 and the value of ifNumber." ::= { axrEthVllStatsQueueEntry 1 } axrEthVllStatsQueueQueIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An index that uniquely identifies the particular queue. Its value ranges between 1 and 4." ::= { axrEthVllStatsQueueEntry 2 } axrEthVllStatsQueuelimitQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The limit value of the length of the output priority queue in the interface is indicated." ::= { axrEthVllStatsQueueEntry 3 } axrEthVllStatsQueueQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length of the output priority queue when information in the interface is gathered is shown. " ::= { axrEthVllStatsQueueEntry 4 } axrEthVllStatsQueueMaxQlen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum length of the output priority queue in a pertinent interface is shown." ::= { axrEthVllStatsQueueEntry 5 } axrEthVllStatsQueueOutFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets transmitted out of the priority queue interface." ::= { axrEthVllStatsQueueEntry 6 } axrEthVllStatsQueueOutBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets transmitted out of the priority queue interface." ::= { axrEthVllStatsQueueEntry 7 } axrEthVllStatsQueueDiscardFrames OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets which were chosen to be discarded." ::= { axrEthVllStatsQueueEntry 8 } axrEthVllStatsQueueDiscardBytes OBJECT-TYPE SYNTAX Counter64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets which were chosen to be discarded." ::= { axrEthVllStatsQueueEntry 9 } --AX2000R DHCP group Variables axrDHCPAddrValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP addresses which are available within this Router." ::= { axrDHCP 1 } axrDHCPFreeAddrValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of IP addresses which are available within this Router. May be expressed as either an absolute value." ::= { axrDHCP 2 } -- OSPF General Variables axrOspfGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfGeneralEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of OSPF information." ::= { axrOspf 1 } axrOspfGeneralEntry OBJECT-TYPE SYNTAX AxrOspfGeneralEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entry of OSPF information." INDEX { axrOspfGeneralDomainNumber } ::= { axrOspfGeneralTable 1 } AxrOspfGeneralEntry ::= SEQUENCE { axrOspfGeneralDomainNumber INTEGER, axrOspfRouterId IpAddress, axrOspfAdminStat INTEGER, axrOspfVersionNumber INTEGER, axrOspfAreaBdrRtrStatus INTEGER, axrOspfASBdrRtrStatus INTEGER, axrOspfExternLsaCount Gauge, axrOspfExternLsaCksumSum INTEGER, axrOspfTOSSupport INTEGER, axrOspfOriginateNewLsas Counter, axrOspfRxNewLsas Counter, axrOspfExtLsdbLimit INTEGER, axrOspfMulticastExtensions INTEGER } axrOspfGeneralDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Domain number in the Autonomous System." ::= { axrOspfGeneralEntry 1 } axrOspfRouterId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "A integer uniquely identifying the router in the Autonomous System." ::= { axrOspfGeneralEntry 2 } axrOspfAdminStat OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The administrative status of OSPF in the router. " ::= { axrOspfGeneralEntry 3 } axrOspfVersionNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current version number of the OSPF protocol is 2." ::= { axrOspfGeneralEntry 4 } axrOspfAreaBdrRtrStatus OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag to note whether this router is an area border router." ::= { axrOspfGeneralEntry 5 } axrOspfASBdrRtrStatus OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION "A flag to note whether this router is configured as an Autonomous System border router." ::= { axrOspfGeneralEntry 6 } axrOspfExternLsaCount OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of external (LS type 5) link-state advertisements in the link-state database." ::= { axrOspfGeneralEntry 7 } axrOspfExternLsaCksumSum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The 32-bit unsigned sum of the LS checksums of the external link-state advertisements contained in the link-state database." ::= { axrOspfGeneralEntry 8 } axrOspfTOSSupport OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The router's support for type-of-service routing. This value of false(2). " ::= { axrOspfGeneralEntry 9 } axrOspfOriginateNewLsas OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of new link-state advertisements that have been originated. " ::= { axrOspfGeneralEntry 10 } axrOspfRxNewLsas OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of link-state advertisements received determined to be new instantiations." ::= { axrOspfGeneralEntry 11 } axrOspfExtLsdbLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of non-default AS-external-LSAs entries that can be stored in the link-state database. If the value is -1, then there is no limit. This value is -1" ::= { axrOspfGeneralEntry 12 } axrOspfMulticastExtensions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A Bit Mask indicating whether the router is forwarding IP multicast (Class D) datagrams based on the algorithms defined in the Multicast Extensions to OSPF." ::= { axrOspfGeneralEntry 13 } axrOspfAreaTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfAreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The router's support for demand routing." ::= { axrOspf 2 } axrOspfAreaEntry OBJECT-TYPE SYNTAX AxrOspfAreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry contain ospf area information." INDEX { axrOspfAreaDomainNumber, axrOspfAreaId } ::= { axrOspfAreaTable 1 } AxrOspfAreaEntry ::= SEQUENCE { axrOspfAreaDomainNumber INTEGER, axrOspfAreaId IpAddress, axrOspfAuthType INTEGER, axrOspfImportAsExtern INTEGER, axrOspfSpfRuns Counter, axrOspfAreaBdrRtrCount Gauge, axrOspfAsBdrRtrCount Gauge, axrOspfAreaLsaCount Gauge, axrOspfAreaLsaCksumSum INTEGER, axrOspfAreaSummary INTEGER, axrOspfAreaStatus INTEGER } axrOspfAreaDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An uniquely identifying number of domain." ::= { axrOspfAreaEntry 1 } axrOspfAreaId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit integer uniquely identifying an area." ::= { axrOspfAreaEntry 2 } axrOspfAuthType OBJECT-TYPE SYNTAX INTEGER -- none(0), -- simplePassword (1), -- md5(2) ACCESS read-only STATUS mandatory DESCRIPTION "The authentication type specified for an area." ::= { axrOspfAreaEntry 3 } axrOspfImportAsExtern OBJECT-TYPE SYNTAX INTEGER { importExternal (1), importNoExternal (2), importNssa (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The area's support for importing AS external link- state advertisements." ::= { axrOspfAreaEntry 4 } axrOspfSpfRuns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the intra-area route table has been calculated using this area's link-state database." ::= { axrOspfAreaEntry 5 } axrOspfAreaBdrRtrCount OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The total number of area border routers reachable within this area." ::= { axrOspfAreaEntry 6 } axrOspfAsBdrRtrCount OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The total number of AS area border routers reachable within this area." ::= { axrOspfAreaEntry 7 } axrOspfAreaLsaCount OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LSA(link-state advertisements) in this area. Excluding AS External LSA's" ::= { axrOspfAreaEntry 8 } axrOspfAreaLsaCksumSum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sum of LSA's LS checksums contained in this area's link-state database." ::= { axrOspfAreaEntry 9 } axrOspfAreaSummary OBJECT-TYPE SYNTAX INTEGER { noAreaSummary (1), sendAreaSummary (2) } ACCESS read-only STATUS mandatory DESCRIPTION "he variable axrOspfAreaSummary controls the import of summary LSAs into stub areas. Value is only sendAreaSummary(2)." ::= { axrOspfAreaEntry 10 } axrOspfAreaStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. Value is only valid(1)." ::= { axrOspfAreaEntry 11 } axrOspfStubAreaTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfStubAreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The set of metrics that will be advertised by a default Area Border Router into a stub area." ::= { axrOspf 3 } axrOspfStubAreaEntry OBJECT-TYPE SYNTAX AxrOspfStubAreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The metric for a given Type of Service that will be advertised by a default Area Border Router into a stub area." INDEX { axrOspfStubDomainNumber, axrOspfStubAreaId, axrOspfStubTOS } ::= { axrOspfStubAreaTable 1 } AxrOspfStubAreaEntry ::= SEQUENCE { axrOspfStubDomainNumber INTEGER, axrOspfStubAreaId IpAddress, axrOspfStubTOS INTEGER, axrOspfStubMetric INTEGER, axrOspfStubStatus INTEGER, axrOspfStubMetricType INTEGER } axrOspfStubDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The domain identifier for the Stub Area." ::= { axrOspfStubAreaEntry 1 } axrOspfStubAreaId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The identifier for the Stub Area." ::= { axrOspfStubAreaEntry 2 } axrOspfStubTOS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Type of Service associated with the metric. Value is only 0." ::= { axrOspfStubAreaEntry 3 } axrOspfStubMetric OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The metric value applied at the indicated type of service." ::= { axrOspfStubAreaEntry 4 } axrOspfStubStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. This value is only valid(1)." ::= { axrOspfStubAreaEntry 5 } axrOspfStubMetricType OBJECT-TYPE SYNTAX INTEGER { ospfMetric(1), comparableCost(2), nonComparable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "his variable displays the type of metric advertised as a default route." ::= { axrOspfStubAreaEntry 6 } axrOspfLsdbTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The OSPF Process's Link State Database." ::= { axrOspf 4 } axrOspfLsdbEntry OBJECT-TYPE SYNTAX AxrOspfLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single Link State Advertisement." INDEX { axrOspfLsdbDomainNumber, axrOspfLsdbAreaId, axrOspfLsdbType, axrOspfLsdbLsid, axrOspfLsdbRouterId } ::= { axrOspfLsdbTable 1 } AxrOspfLsdbEntry ::= SEQUENCE { axrOspfLsdbDomainNumber INTEGER, axrOspfLsdbAreaId IpAddress, axrOspfLsdbType INTEGER, axrOspfLsdbLsid IpAddress, axrOspfLsdbRouterId IpAddress, axrOspfLsdbSequence INTEGER, axrOspfLsdbAge INTEGER, axrOspfLsdbChecksum INTEGER, axrOspfLsdbAdvertisement OCTET STRING } axrOspfLsdbDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The identifier of the domain from which the LSA was received." ::= { axrOspfLsdbEntry 1 } axrOspfLsdbAreaId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The 32 bit identifier of the Area from which the LSA was received." ::= { axrOspfLsdbEntry 2 } axrOspfLsdbType OBJECT-TYPE SYNTAX INTEGER { routerLink (1), networkLink (2), summaryLink (3), asSummaryLink (4), asExternalLink (5), -- but see axrOspfExtLsdbTable multicastLink (6), nssaExternalLink (7) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the link state advertisement." ::= { axrOspfLsdbEntry 3 } axrOspfLsdbLsid OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Link State ID . It identifies the piece of the routing domain that is being described by the advertisement." ::= { axrOspfLsdbEntry 4 } axrOspfLsdbRouterId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The number that uniquely identifies the originating router in the Autonomous System." ::= { axrOspfLsdbEntry 5 } axrOspfLsdbSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number field is a signed 32-bit integer." ::= { axrOspfLsdbEntry 6 } axrOspfLsdbAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This the age of the link state adver- tisement in seconds." ::= { axrOspfLsdbEntry 7 } axrOspfLsdbChecksum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This field is the checksum of the complete contents of the advertisement, excepting the age field." ::= { axrOspfLsdbEntry 8 } axrOspfLsdbAdvertisement OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The entire Link State Advertisement, including its header." ::= { axrOspfLsdbEntry 9 } axrOspfAreaRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfAreaRangeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A range if IP addresses specified by an IP address/IP network mask pair." ::= { axrOspf 5 } axrOspfAreaRangeEntry OBJECT-TYPE SYNTAX AxrOspfAreaRangeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A range if IP addresses specified by an IP address/IP network mask pair." INDEX { axrOspfAreaRangeDomainNumber, axrOspfAreaRangeAreaId, axrOspfAreaRangeNet } ::= { axrOspfAreaRangeTable 1 } AxrOspfAreaRangeEntry ::= SEQUENCE { axrOspfAreaRangeDomainNumber INTEGER, axrOspfAreaRangeAreaId IpAddress, axrOspfAreaRangeNet IpAddress, axrOspfAreaRangeMask IpAddress, axrOspfAreaRangeStatus INTEGER, axrOspfAreaRangeEffect INTEGER } axrOspfAreaRangeDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Domain number of the Area." ::= { axrOspfAreaRangeEntry 1 } axrOspfAreaRangeAreaId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Area the Address Range is to be found within." ::= { axrOspfAreaRangeEntry 2 } axrOspfAreaRangeNet OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP Address of the Net or Subnet indicated by the range." ::= { axrOspfAreaRangeEntry 3 } axrOspfAreaRangeMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Subnet Mask that pertains to the Net or Subnet." ::= { axrOspfAreaRangeEntry 4 } axrOspfAreaRangeStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. This value is only valid(1)." ::= { axrOspfAreaRangeEntry 5 } axrOspfAreaRangeEffect OBJECT-TYPE SYNTAX INTEGER { advertiseMatching (1), doNotAdvertiseMatching (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Subnets subsumed by ranges either trigger the advertisement of the indicated summary (adver- tiseMatching), or result in the subnet's not being advertised at all outside the area." ::= { axrOspfAreaRangeEntry 6 } axrOspfHostTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfHostEntry --SHIMO EDIT ACCESS not-accessible STATUS mandatory DESCRIPTION "The list of Hosts, and their metrics, that the router will advertise as host routes." ::= { axrOspf 6 } axrOspfHostEntry OBJECT-TYPE SYNTAX AxrOspfHostEntry --SHIMO EDIT ACCESS not-accessible STATUS mandatory DESCRIPTION "A metric to be advertised, for a given type of service, when a given host is reachable." INDEX { axrOspfHostDomainNumber, axrOspfHostIpAddress, axrOspfHostTOS } ::= { axrOspfHostTable 1 } AxrOspfHostEntry ::= SEQUENCE { axrOspfHostDomainNumber INTEGER, axrOspfHostIpAddress IpAddress, axrOspfHostTOS INTEGER, axrOspfHostMetric INTEGER, axrOspfHostStatus INTEGER } axrOspfHostDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "OSPF domain number of the Host." ::= { axrOspfHostEntry 1 } axrOspfHostIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP Address of the Host." ::= { axrOspfHostEntry 2 } axrOspfHostTOS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Type of Service of the route being configured. This value is only 0." ::= { axrOspfHostEntry 3 } axrOspfHostMetric OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Metric to be advertised." ::= { axrOspfHostEntry 4 } axrOspfHostStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent." ::= { axrOspfHostEntry 5 } axrOspfIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The OSPF Interface Table describes the interfaces from the viewpoint of OSPF." ::= { axrOspf 7 } axrOspfIfEntry OBJECT-TYPE SYNTAX AxrOspfIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The OSPF Interface Entry describes one interface from the viewpoint of OSPF." INDEX { axrOspfIfDomainNumber, axrOspfIfIpAddress, axrOspfAddressLessIf } ::= { axrOspfIfTable 1 } AxrOspfIfEntry ::= SEQUENCE { axrOspfIfDomainNumber INTEGER, axrOspfIfIpAddress IpAddress, axrOspfAddressLessIf INTEGER, axrOspfIfAreaId IpAddress, axrOspfIfType INTEGER, axrOspfIfAdminStat INTEGER, axrOspfIfRtrPriority INTEGER, axrOspfIfTransitDelay INTEGER, axrOspfIfRetransInterval INTEGER, axrOspfIfHelloInterval INTEGER, axrOspfIfRtrDeadInterval INTEGER, axrOspfIfPollInterval INTEGER, axrOspfIfState INTEGER, axrOspfIfDesignatedRouter IpAddress, axrOspfIfEvents Counter, axrOspfIfAuthKey OCTET STRING, axrOspfIfStatus INTEGER, axrOspfIfMulticastForwarding INTEGER, axrOspfIfBackupDesignatedRouter IpAddress } axrOspfIfDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The domain number of this OSPF interface." ::= { axrOspfIfEntry 1 } axrOspfIfIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of this OSPF interface." ::= { axrOspfIfEntry 2 } axrOspfAddressLessIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For the purpose of easing the instancing of addressed and addressless interfaces; This variable takes the value 0 on interfaces with IP Addresses, and the corresponding value of ifIndex for interfaces having no IP Address." ::= { axrOspfIfEntry 3 } axrOspfIfAreaId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "A integer uniquely identifying the area to which the interface connects." ::= { axrOspfIfEntry 4 } axrOspfIfType OBJECT-TYPE SYNTAX INTEGER { broadcast (1), nbma (2), pointToPoint (3), pointToMultipoint (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The OSPF interface type." ::= { axrOspfIfEntry 5 } axrOspfIfAdminStat OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The OSPF interface's administrative status." ::= { axrOspfIfEntry 6 } axrOspfIfRtrPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The priority of this interface." ::= { axrOspfIfEntry 7 } axrOspfIfTransitDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The estimated number of seconds it takes to transmit a link state update packet over this interface." ::= { axrOspfIfEntry 8 } axrOspfIfRetransInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds between link-state ad- vertisement retransmissions, for adjacencies belonging to this interface." ::= { axrOspfIfEntry 9 } axrOspfIfHelloInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length of time, in seconds, between the Hello packets that the router sends on the interface." ::= { axrOspfIfEntry 10 } axrOspfIfRtrDeadInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a router's Hello packets have not been seen before it's neighbors declare the router down." ::= { axrOspfIfEntry 11 } axrOspfIfPollInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The larger time interval, in seconds, between the Hello packets sent to an inactive non- broadcast multi- access neighbor." ::= { axrOspfIfEntry 12 } axrOspfIfState OBJECT-TYPE SYNTAX INTEGER { down (1), loopback (2), waiting (3), pointToPoint (4), designatedRouter (5), backupDesignatedRouter (6), otherDesignatedRouter (7) } ACCESS read-only STATUS mandatory DESCRIPTION "The OSPF Interface State." ::= { axrOspfIfEntry 13 } axrOspfIfDesignatedRouter OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP Address of the Designated Router." ::= { axrOspfIfEntry 14 } axrOspfIfEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this OSPF interface has changed its state, or an error has occurred." ::= { axrOspfIfEntry 16 } axrOspfIfAuthKey OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Authentication Key." ::= { axrOspfIfEntry 17 } axrOspfIfStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. this value is only valid(1)." ::= { axrOspfIfEntry 18 } axrOspfIfMulticastForwarding OBJECT-TYPE SYNTAX INTEGER { blocked (1), -- no multicast forwarding multicast (2), -- using multicast address unicast (3) -- to each OSPF neighbor } ACCESS read-only STATUS mandatory DESCRIPTION "The way multicasts should forwarded on this interface; not forwarded, forwarded as data link multicasts, or forwarded as data link unicasts." ::= { axrOspfIfEntry 19 } axrOspfIfBackupDesignatedRouter OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP Address of the Backup Designated Router." ::= { axrOspfIfEntry 15 } axrOspfIfMetricTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfIfMetricEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The TOS metrics for a non-virtual interface identified by the interface index." ::= { axrOspf 8 } axrOspfIfMetricEntry OBJECT-TYPE SYNTAX AxrOspfIfMetricEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A particular TOS metric for a non-virtual interface identified by the interface index." INDEX { axrOspfIfMetricDomainNumber, axrOspfIfMetricIpAddress, axrOspfIfMetricAddressLessIf, axrOspfIfMetricTOS } ::= { axrOspfIfMetricTable 1 } AxrOspfIfMetricEntry ::= SEQUENCE { axrOspfIfMetricDomainNumber INTEGER, axrOspfIfMetricIpAddress IpAddress, axrOspfIfMetricAddressLessIf INTEGER, axrOspfIfMetricTOS INTEGER, axrOspfIfMetricValue INTEGER, axrOspfIfMetricStatus INTEGER } axrOspfIfMetricDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The domain number of this OSPF interface." ::= { axrOspfIfMetricEntry 1 } axrOspfIfMetricIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of this OSPF interface." ::= { axrOspfIfMetricEntry 2 } axrOspfIfMetricAddressLessIf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "For the purpose of easing the instancing of addressed and addressless interfaces; This variable takes the value 0 on interfaces with IP Addresses, and the value of ifIndex for in- terfaces having no IP Address." ::= { axrOspfIfMetricEntry 3 } axrOspfIfMetricTOS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The type of service metric being referenced. this value is only 0." ::= { axrOspfIfMetricEntry 4 } axrOspfIfMetricValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The metric of using this type of service on this interface." ::= { axrOspfIfMetricEntry 5 } axrOspfIfMetricStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. This entry status is only valid(1)." ::= { axrOspfIfMetricEntry 6 } axrOspfVirtIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfVirtIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about this router's virtual interfaces." ::= { axrOspf 9 } axrOspfVirtIfEntry OBJECT-TYPE SYNTAX AxrOspfVirtIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a single Virtual Interface." INDEX { axrOspfVirtIfDomainNumber, axrOspfVirtIfAreaId, axrOspfVirtIfNeighbor } ::= { axrOspfVirtIfTable 1 } AxrOspfVirtIfEntry ::= SEQUENCE { axrOspfVirtIfDomainNumber INTEGER, axrOspfVirtIfAreaId IpAddress, axrOspfVirtIfNeighbor IpAddress, axrOspfVirtIfTransitDelay INTEGER, axrOspfVirtIfRetransInterval INTEGER, axrOspfVirtIfHelloInterval INTEGER, axrOspfVirtIfRtrDeadInterval INTEGER, axrOspfVirtIfState INTEGER, axrOspfVirtIfEvents Counter, axrOspfVirtIfAuthKey OCTET STRING, axrOspfVirtIfStatus INTEGER } axrOspfVirtIfDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The domain number for this Virtual Interface" ::= { axrOspfVirtIfEntry 1 } axrOspfVirtIfAreaId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Transit Area that the Virtual Link traverses." ::= { axrOspfVirtIfEntry 2 } axrOspfVirtIfNeighbor OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Router ID of the Virtual Neighbor." ::= { axrOspfVirtIfEntry 3 } axrOspfVirtIfTransitDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The estimated number of seconds it takes to transmit a link- state update packet over this interface." ::= { axrOspfVirtIfEntry 4 } axrOspfVirtIfRetransInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds between link-state advertisement retransmissions, for adjacencies belonging to this interface." ::= { axrOspfVirtIfEntry 5 } axrOspfVirtIfHelloInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length of time, in seconds, between the Hello packets that the router sends on the in- terface. " ::= { axrOspfVirtIfEntry 6 } axrOspfVirtIfRtrDeadInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a router's Hello packets have not been seen before it's neighbors declare the router down." ::= { axrOspfVirtIfEntry 7 } axrOspfVirtIfState OBJECT-TYPE SYNTAX INTEGER { down (1), -- these use the same encoding pointToPoint (4) -- as the axrOspfIfTable } ACCESS read-only STATUS mandatory DESCRIPTION "OSPF virtual interface states." ::= { axrOspfVirtIfEntry 8 } axrOspfVirtIfEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of state changes or error events on this Virtual Link" ::= { axrOspfVirtIfEntry 9 } axrOspfVirtIfAuthKey OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Authentication key of this interface." ::= { axrOspfVirtIfEntry 10 } axrOspfVirtIfStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. This entry is only valid(1)." ::= { axrOspfVirtIfEntry 11 } axrOspfNbrTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfNbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of non-virtual neighbor information." ::= { axrOspf 10 } axrOspfNbrEntry OBJECT-TYPE SYNTAX AxrOspfNbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information regarding a single neighbor." INDEX { axrOspfNbrDomainNumber, axrOspfNbrIpAddr, axrOspfNbrAddressLessIndex } ::= { axrOspfNbrTable 1 } AxrOspfNbrEntry ::= SEQUENCE { axrOspfNbrDomainNumber INTEGER, axrOspfNbrIpAddr IpAddress, axrOspfNbrAddressLessIndex INTEGER, axrOspfNbrRtrId IpAddress, axrOspfNbrOptions INTEGER, axrOspfNbrPriority INTEGER, axrOspfNbrState INTEGER, axrOspfNbrEvents Counter, axrOspfNbrLsRetransQLen Gauge, axrOspfNbmaNbrStatus INTEGER, axrOspfNbmaNbrPermanence INTEGER } axrOspfNbrDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "OSPF domain number of this neighbor." ::= { axrOspfNbrEntry 1 } axrOspfNbrIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address this neighbor is using in its IP Source Address." ::= { axrOspfNbrEntry 2 } axrOspfNbrAddressLessIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "On an interface having an IP Address, zero. On addressless interfaces, the corresponding value of ifIndex in the Internet Standard MIB." ::= { axrOspfNbrEntry 3 } axrOspfNbrRtrId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The integer uniquely identifying the neighboring router in the Autonomous System." ::= { axrOspfNbrEntry 4 } axrOspfNbrOptions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A Bit Mask corresponding to the neighbor's op- tions field. Bit 0, if set, indicates that the system will operate on Type of Service metrics other than TOS 0. If zero, the neighbor will ignore all metrics except the TOS 0 metric. Bit 1, if set, indicates that the associated area accepts and operates on external informa- tion; if zero, it is a stub area. Bit 2, if set, indicates that the system is ca- pable of routing IP Multicast datagrams; i.e., that it implements the Multicast Extensions to OSPF. Bit 3, if set, indicates that the associated area is an NSSA. These areas are capable of carrying type 7 external advertisements, which are translated into type 5 external advertise- ments at NSSA borders." ::= { axrOspfNbrEntry 5 } axrOspfNbrPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The priority of this neighbor." ::= { axrOspfNbrEntry 6 } axrOspfNbrState OBJECT-TYPE SYNTAX INTEGER { down (1), attempt (2), init (3), twoWay (4), exchangeStart (5), exchange (6), loading (7), full (8) } ACCESS read-only STATUS mandatory DESCRIPTION "The State of the relationship with this Neighbor." ::= { axrOspfNbrEntry 7 } axrOspfNbrEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this neighbor relationship has changed state, or an error has occurred." ::= { axrOspfNbrEntry 8 } axrOspfNbrLsRetransQLen OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The current length of the retransmission queue." ::= { axrOspfNbrEntry 9 } axrOspfNbmaNbrStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. This entry value is only valid(1). And enable to response this entry when axrOspfIfType is nbma." ::= { axrOspfNbrEntry 10 } axrOspfNbmaNbrPermanence OBJECT-TYPE SYNTAX INTEGER { dynamic (1), -- learned through protocol permanent (2) -- configured address } ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry." ::= { axrOspfNbrEntry 11 } axrOspfVirtNbrTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfVirtNbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of virtual neighbor information." ::= { axrOspf 11 } axrOspfVirtNbrEntry OBJECT-TYPE SYNTAX AxrOspfVirtNbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Virtual neighbor information." INDEX { axrOspfVirtNbrDomainNumber, axrOspfVirtNbrArea, axrOspfVirtNbrRtrId } ::= { axrOspfVirtNbrTable 1 } AxrOspfVirtNbrEntry ::= SEQUENCE { axrOspfVirtNbrDomainNumber INTEGER, axrOspfVirtNbrArea IpAddress, axrOspfVirtNbrRtrId IpAddress, axrOspfVirtNbrIpAddr IpAddress, axrOspfVirtNbrOptions INTEGER, axrOspfVirtNbrState INTEGER, axrOspfVirtNbrEvents Counter, axrOspfVirtNbrLsRetransQLen Gauge } axrOspfVirtNbrDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The domain number." ::= { axrOspfVirtNbrEntry 1 } axrOspfVirtNbrArea OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Transit Area Identifier." ::= { axrOspfVirtNbrEntry 2 } axrOspfVirtNbrRtrId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "A integer uniquely identifying the neighboring router in the Autonomous System." ::= { axrOspfVirtNbrEntry 3 } axrOspfVirtNbrIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address this Virtual Neighbor is using." ::= { axrOspfVirtNbrEntry 4 } axrOspfVirtNbrOptions OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A Bit Mask corresponding to the neighbor's options field. Bit 1, if set, indicates that the system will operate on Type of Service metrics other than TOS 0. If zero, the neighbor will ignore all metrics except the TOS 0 metric. Bit 2, if set, indicates that the system is Network Multicast capable; ie, that it implements OSPF Multicast Routing." ::= { axrOspfVirtNbrEntry 5 } axrOspfVirtNbrState OBJECT-TYPE SYNTAX INTEGER { down (1), attempt (2), init (3), twoWay (4), exchangeStart (5), exchange (6), loading (7), full (8) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the Virtual Neighbor Relationship." ::= { axrOspfVirtNbrEntry 6 } axrOspfVirtNbrEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this virtual link has changed its state, or an error has occurred." ::= { axrOspfVirtNbrEntry 7 } axrOspfVirtNbrLsRetransQLen OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The current length of the retransmission queue." ::= { axrOspfVirtNbrEntry 8 } axrOspfExtLsdbTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfExtLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The OSPF Process's Links State Database." ::= { axrOspf 12 } axrOspfExtLsdbEntry OBJECT-TYPE SYNTAX AxrOspfExtLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single Link State Advertisement." INDEX { axrOspfExtLsdbDomainNumber, axrOspfExtLsdbType, axrOspfExtLsdbLsid, axrOspfExtLsdbRouterId } ::= { axrOspfExtLsdbTable 1 } AxrOspfExtLsdbEntry ::= SEQUENCE { axrOspfExtLsdbDomainNumber INTEGER, axrOspfExtLsdbType INTEGER, axrOspfExtLsdbLsid IpAddress, axrOspfExtLsdbRouterId IpAddress, axrOspfExtLsdbSequence INTEGER, axrOspfExtLsdbAge INTEGER, axrOspfExtLsdbChecksum INTEGER, axrOspfExtLsdbAdvertisement OCTET STRING } axrOspfExtLsdbDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "OSPF domain number." ::= { axrOspfExtLsdbEntry 1 } axrOspfExtLsdbType OBJECT-TYPE SYNTAX INTEGER { asExternalLink (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the link state advertisement." ::= { axrOspfExtLsdbEntry 2 } axrOspfExtLsdbLsid OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Link State ID is an LS Type Specific field containing either a Router ID or an IP Address; it identifies the piece of the routing domain that is being described by the advertisement." ::= { axrOspfExtLsdbEntry 3 } axrOspfExtLsdbRouterId OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The 32 bit number that uniquely identifies the originating router in the Autonomous System." ::= { axrOspfExtLsdbEntry 4 } axrOspfExtLsdbSequence OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number field is a signed 32-bit integer." ::= { axrOspfExtLsdbEntry 5 } axrOspfExtLsdbAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The age of the link state advertisement in seconds." ::= { axrOspfExtLsdbEntry 6 } axrOspfExtLsdbChecksum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum." ::= { axrOspfExtLsdbEntry 7 } axrOspfExtLsdbAdvertisement OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The entire Link State Advertisement, including its header." ::= { axrOspfExtLsdbEntry 8 } axrOspfAreaAggregateTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfAreaAggregateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A range of IP addresses specified by an IP address/IP network mask pair." ::= { axrOspf 14 } axrOspfAreaAggregateEntry OBJECT-TYPE SYNTAX AxrOspfAreaAggregateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A range of IP addresses specified by an IP address/IP network mask pair." INDEX { axrOspfAreaAggregateDomainNumber, axrOspfAreaAggregateAreaID, axrOspfAreaAggregateLsdbType, axrOspfAreaAggregateNet, axrOspfAreaAggregateMask } ::= { axrOspfAreaAggregateTable 1 } AxrOspfAreaAggregateEntry ::= SEQUENCE { axrOspfAreaAggregateDomainNumber INTEGER, axrOspfAreaAggregateAreaID IpAddress, axrOspfAreaAggregateLsdbType INTEGER, axrOspfAreaAggregateNet IpAddress, axrOspfAreaAggregateMask IpAddress, axrOspfAreaAggregateStatus INTEGER, axrOspfAreaAggregateEffect INTEGER } axrOspfAreaAggregateDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "OSPF domain number." ::= { axrOspfAreaAggregateEntry 1 } axrOspfAreaAggregateAreaID OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Area the Address Aggregate is to be found within." ::= { axrOspfAreaAggregateEntry 2 } axrOspfAreaAggregateLsdbType OBJECT-TYPE SYNTAX INTEGER { summaryLink (3), nssaExternalLink (7) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the Address Aggregate. This field specifies the Lsdb type that this Address Aggregate applies to." ::= { axrOspfAreaAggregateEntry 3 } axrOspfAreaAggregateNet OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP Address of the Net or Subnet indicated by the range." ::= { axrOspfAreaAggregateEntry 4 } axrOspfAreaAggregateMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Subnet Mask that pertains to the Net or Subnet." ::= { axrOspfAreaAggregateEntry 5 } axrOspfAreaAggregateStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the entry. This entry value is only valid(1)." ::= { axrOspfAreaAggregateEntry 6 } axrOspfAreaAggregateEffect OBJECT-TYPE SYNTAX INTEGER { advertiseMatching (1), doNotAdvertiseMatching (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Subnets subsumed by ranges either trigger the advertisement of the indicated aggregate (ad- vertiseMatching), or result in the subnet's not being advertised at all outside the area." ::= { axrOspfAreaAggregateEntry 7 } -- axrOspfv3 axrOspfv3GeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3GeneralEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table which ospfv3 information is stored in." ::= { axrOspfv3 1 } axrOspfv3GeneralEntry OBJECT-TYPE SYNTAX AxrOspfv3GeneralEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The list of the ospfv3 information." INDEX { axrOspfv3GeneralDomainNumber } ::= { axrOspfv3GeneralTable 1 } AxrOspfv3GeneralEntry ::= SEQUENCE { axrOspfv3GeneralDomainNumber INTEGER, axrOspfv3RouterId RouterID, axrOspfv3AdminStat Status, axrOspfv3VersionNumber INTEGER, axrOspfv3AreaBdrRtrStatus TruthValue, axrOspfv3ASBdrRtrStatus TruthValue, axrOspfv3AsScopeLsaCount Gauge32, axrOspfv3AsScopeLsaCksumSum Integer32, axrOspfv3OriginateNewLsas Integer32, axrOspfv3RxNewLsas Counter32, axrOspfv3ExtAreaLsdbLimit Integer32, axrOspfv3MulticastExtensions Integer32, axrOspfv3DemandExtensions TruthValue, axrOspfv3TrafficEngineeringSupport TruthValue } axrOspfv3GeneralDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3GeneralEntry 1 } axrOspfv3RouterId OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit integer uniquely identifying the router in the Autonomous System. By convention, to ensure uniqueness, this should default to the value of one of the router's IPv4 interface addresses if IPv4 is configured." ::= { axrOspfv3GeneralEntry 2 } axrOspfv3AdminStat OBJECT-TYPE SYNTAX Status ACCESS read-only STATUS mandatory DESCRIPTION "The administrative status of axrOspfv3 in the router. The value 'enabled' denotes that the axrOspfv3 Process is active on at least one inter- face; 'disabled' disables it on all inter- faces." ::= { axrOspfv3GeneralEntry 3 } axrOspfv3VersionNumber OBJECT-TYPE SYNTAX INTEGER { version3 (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The version number of OSPF for IPv6 is 3." ::= { axrOspfv3GeneralEntry 4 } axrOspfv3AreaBdrRtrStatus OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "A flag to note whether this router is an area border router." REFERENCE "OSPF Version 2, Section 3 Splitting the AS into Areas" ::= { axrOspfv3GeneralEntry 5 } axrOspfv3ASBdrRtrStatus OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "A flag to note whether this router is config- ured as an Autonomous System border router." REFERENCE "OSPF Version 2, Section 3.3 Classification of routers" ::= { axrOspfv3GeneralEntry 6 } axrOspfv3AsScopeLsaCount OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of AS-Scope (e.g. AS-External) link-state advertisements in the link-state database." ::= { axrOspfv3GeneralEntry 7 } axrOspfv3AsScopeLsaCksumSum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The 32-bit unsigned sum of the LS checksums of the AS-scoped link-state advertisements con- tained in the link-state database. This sum can be used to determine if there has been a change in a router's link state database, and to compare the link-state database of two routers." ::= { axrOspfv3GeneralEntry 8 } axrOspfv3OriginateNewLsas OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of new link-state advertisements that have been originated. This number is in- cremented each time the router originates a new LSA." ::= { axrOspfv3GeneralEntry 9 } axrOspfv3RxNewLsas OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of link-state advertisements re- ceived determined to be new instantiations. This number does not include newer instantia- tions of self-originated link-state advertise- ments." ::= { axrOspfv3GeneralEntry 10 } axrOspfv3ExtAreaLsdbLimit OBJECT-TYPE SYNTAX Integer32 (-1..'7FFFFFFF'h) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of non-default AS- external-LSAs entries that can be stored in the link-state database. If the value is -1, then there is no limit. When the number of non-default AS-external-LSAs in a router's link-state database reaches axrOspfv3ExtAreaLsdbLimit, the router enters Overflow- State. The router never holds more than axrOspfv3ExtAreaLsdbLimit non-default AS-external-LSAs in its database. OspfExtAreaLsdbLimit MUST be set identically in all routers attached to the axrOspfv3 backbone and/or any regular axrOspfv3 area. (i.e., axrOspfv3 stub areas and NSSAs are excluded)." DEFVAL { -1 } ::= { axrOspfv3GeneralEntry 11 } axrOspfv3MulticastExtensions OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "A Bit Mask indicating whether the router is forwarding IPv6 multicast datagrams based on the algorithms defined in the Multi- cast Extensions to OSPF. Bit 0, if set, indicates that the router can forward IPv6 multicast datagrams in the router's directly attached areas (called intra-area mul- ticast routing). Bit 1, if set, indicates that the router can forward IPv6 multicast datagrams between axrOspfv3 areas (called inter-area multicast routing). Bit 2, if set, indicates that the router can forward IPv6 multicast datagrams between Auto- nomous Systems (called inter-AS multicast rout- ing). Only certain combinations of bit settings are allowed, namely: 0 (no multicast forwarding is enabled), 1 (intra-area multicasting only), 3 (intra-area and inter-area multicasting), 5 (intra-area and inter-AS multicasting) and 7 (multicasting everywhere). By default, no mul- ticast forwarding is enabled." DEFVAL { 0 } ::= { axrOspfv3GeneralEntry 12 } axrOspfv3DemandExtensions OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "The router's support for demand routing." REFERENCE "OSPF Version 2, Appendix on Demand Routing" ::= { axrOspfv3GeneralEntry 14 } axrOspfv3TrafficEngineeringSupport OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "The router's support for traffic engineering extensions." ::= { axrOspfv3GeneralEntry 15 } -- The axrOspfv3 Area Data Structure contains information -- regarding the various areas. The interfaces and -- virtual links are configured as part of these areas. -- Area 0.0.0.0, by definition, is the Backbone Area axrOspfv3AreaTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3AreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information describing the configured parame- ters and cumulative statistics of the router's attached areas." REFERENCE "OSPF Version 2, Section 6 The Area Data Struc- ture" ::= { axrOspfv3 2 } axrOspfv3AreaEntry OBJECT-TYPE SYNTAX AxrOspfv3AreaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information describing the configured parame- ters and cumulative statistics of one of the router's attached areas." INDEX { axrOspfv3AreaId } ::= { axrOspfv3AreaTable 1 } AxrOspfv3AreaEntry ::= SEQUENCE { axrOspfv3AreaDomainNumber INTEGER, axrOspfv3AreaId AreaID, axrOspfv3ImportAsExtern INTEGER, axrOspfv3SpfRuns Counter32, axrOspfv3AreaBdrRtrCount Gauge32, axrOspfv3AsBdrRtrCount Gauge32, axrOspfv3AreaScopeLsaCount Gauge32, axrOspfv3AreaScopeLsaCksumSum Integer32, axrOspfv3AreaSummary INTEGER, axrOspfv3AreaStatus RowStatus, axrOspfv3StubMetric BigMetric -- axrOspfv3AreaNssaTranslatorRole -- INTEGER, -- axrOspfv3AreaNssaTranslatorState -- INTEGER, -- axrOspfv3AreaNssaTranslatorStabilityInterval -- PositiveInteger, -- axrOspfv3AreaNssaTranslatorEvents -- Counter32 } axrOspfv3AreaDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3AreaEntry 1 } axrOspfv3AreaId OBJECT-TYPE SYNTAX AreaID ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit integer uniquely identifying an area. Area ID 0.0.0.0 is used for the axrOspfv3 backbone." REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" ::= { axrOspfv3AreaEntry 2 } axrOspfv3ImportAsExtern OBJECT-TYPE SYNTAX INTEGER { importExternal (1), -- normal area importNoExternal (2), -- stub area importNssa (3) -- not-so-stubby-area } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether an area is a Stub area, NSSA, or standard area. AS-scope LSAs are not imported into Stub Areas or NSSAs. NSSAs import AS-External data as Type-7 LSAs which have Area-scope" REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" DEFVAL { importExternal } ::= { axrOspfv3AreaEntry 3 } axrOspfv3SpfRuns OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the intra-area route table has been calculated using this area's link-state database. This is typically done using Dijkstra's algorithm." ::= { axrOspfv3AreaEntry 4 } axrOspfv3AreaBdrRtrCount OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of area border routers reach- able within this area. This is initially zero, and is calculated in each SPF Pass." ::= { axrOspfv3AreaEntry 5 } axrOspfv3AsBdrRtrCount OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Autonomous System border routers reachable within this area. This is initially zero, and is calculated in each SPF Pass." ::= { axrOspfv3AreaEntry 6 } axrOspfv3AreaScopeLsaCount OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Area-Scope link-state advertisements in this area's link-state database." ::= { axrOspfv3AreaEntry 7 } axrOspfv3AreaScopeLsaCksumSum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The 32-bit unsigned sum of the Area-Scope link-state advertisements' LS checksums contained in this area's link-state database. The sum can be used to determine if there has been a change in a router's link state database, and to compare the link-state database of two routers." DEFVAL { 0 } ::= { axrOspfv3AreaEntry 8 } axrOspfv3AreaSummary OBJECT-TYPE SYNTAX INTEGER { noAreaSummary (1), sendAreaSummary (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The variable axrOspfv3AreaSummary controls the im- port of summary LSAs into stub areas. It has no effect on other areas. If it is noAreaSummary, the router will neither originate nor propagate summary LSAs into the stub area. It will rely entirely on its de- fault route. If it is sendAreaSummary, the router will both summarize and propagate summary LSAs." DEFVAL { noAreaSummary } ::= { axrOspfv3AreaEntry 9 } axrOspfv3AreaStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the en- try. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent." ::= { axrOspfv3AreaEntry 10 } axrOspfv3StubMetric OBJECT-TYPE SYNTAX BigMetric ACCESS read-create STATUS mandatory DESCRIPTION "The metric value advertised for the default route into Stub and NSSA areas." ::= { axrOspfv3AreaEntry 11 } -- axrOspfv3 AS-Scope Link State Database -- The Link State Database contains the AS-Scope Link State -- Advertisements from throughout the areas that the -- device is attached to. axrOspfv3AsLsdbTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3AsLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The axrOspfv3 Process's AS-Scope Link State Database." ::= { axrOspfv3 3 } axrOspfv3AsLsdbEntry OBJECT-TYPE SYNTAX AxrOspfv3AsLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single AS-Scope Link State Advertisement." INDEX { axrOspfv3AsLsdbType, axrOspfv3AsLsdbRouterId, axrOspfv3AsLsdbLsid } ::= { axrOspfv3AsLsdbTable 1 } AxrOspfv3AsLsdbEntry ::= SEQUENCE { axrOspfv3AsLsdbDomainNumber INTEGER, axrOspfv3AsLsdbType INTEGER, axrOspfv3AsLsdbRouterId RouterID, axrOspfv3AsLsdbLsid IpAddress, axrOspfv3AsLsdbSequence Integer32, axrOspfv3AsLsdbAge Integer32, axrOspfv3AsLsdbChecksum Integer32, axrOspfv3AsLsdbAdvertisement OCTET STRING } axrOspfv3AsLsdbDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3AsLsdbEntry 1 } axrOspfv3AsLsdbType OBJECT-TYPE SYNTAX INTEGER { asExternalLink (16389) -- 0x4005 } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the link state advertisement. Each link state type has a separate advertise- ment format. Unrecognized AS-Scope LSAs with the U-bit set are also store in this database." ::= { axrOspfv3AsLsdbEntry 2 } axrOspfv3AsLsdbRouterId OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "The 32 bit number that uniquely identifies the originating router in the Autonomous System." REFERENCE "OSPF Version 2, Appendix C.1 Global parameters" ::= { axrOspfv3AsLsdbEntry 3 } axrOspfv3AsLsdbLsid OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Link State ID is an LS Type Specific field containing either a Router ID or a unique identifier; it identifies the piece of the routing domain that is being described by the advertisement. In contrast to OSPF for IPv4, the LSID has no addressing semantics." ::= { axrOspfv3AsLsdbEntry 4 } -- Note that the OSPF Sequence Number is a 32 bit signed -- integer. It starts with the value '80000001'h, -- or -'7FFFFFFF'h, and increments until '7FFFFFFF'h -- Thus, a typical sequence number will be very negative. axrOspfv3AsLsdbSequence OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number field is a signed 32-bit integer. It is used to detect old and dupli- cate link state advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number the more recent the advertisement." REFERENCE "OSPF Version 2, Section 12.1.6 LS sequence number" ::= { axrOspfv3AsLsdbEntry 5 } axrOspfv3AsLsdbAge OBJECT-TYPE SYNTAX Integer32 -- Should be 0..MaxAge ACCESS read-only STATUS mandatory DESCRIPTION "This field is the age of the link state adver- tisement in seconds." REFERENCE "OSPF Version 2, Section 12.1.1 LS age" ::= { axrOspfv3AsLsdbEntry 6 } axrOspfv3AsLsdbChecksum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connec- tionless datagrams; it is commonly referred to as the Fletcher checksum." REFERENCE "OSPF Version 2, Section 12.1.7 LS checksum" ::= { axrOspfv3AsLsdbEntry 7 } axrOspfv3AsLsdbAdvertisement OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..65535)) ACCESS read-only STATUS mandatory DESCRIPTION "The entire Link State Advertisement, including its header." ::= { axrOspfv3AsLsdbEntry 8 } -- axrOspfv3 Area-Scope Link State Database -- The Link State Database contains the Area-Scope Link State -- Advertisements from throughout the area that the -- device is attached to. axrOspfv3AreaLsdbTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3AreaLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The axrOspfv3 Process's Area-Scope Link State Database." ::= { axrOspfv3 4 } axrOspfv3AreaLsdbEntry OBJECT-TYPE SYNTAX AxrOspfv3AreaLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single Area-Scope Link State Advertisement." INDEX { axrOspfv3AreaLsdbAreaId, axrOspfv3AreaLsdbType, axrOspfv3AreaLsdbRouterId, axrOspfv3AreaLsdbLsid } ::= { axrOspfv3AreaLsdbTable 1 } AxrOspfv3AreaLsdbEntry ::= SEQUENCE { axrOspfv3AreaLsdbDomainNumber INTEGER, axrOspfv3AreaLsdbAreaId AreaID, axrOspfv3AreaLsdbType INTEGER, axrOspfv3AreaLsdbRouterId RouterID, axrOspfv3AreaLsdbLsid IpAddress, axrOspfv3AreaLsdbSequence Integer32, axrOspfv3AreaLsdbAge Integer32, axrOspfv3AreaLsdbChecksum Integer32, axrOspfv3AreaLsdbAdvertisement OCTET STRING } axrOspfv3AreaLsdbDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3AreaLsdbEntry 1 } axrOspfv3AreaLsdbAreaId OBJECT-TYPE SYNTAX AreaID ACCESS read-only STATUS mandatory DESCRIPTION "The 32 bit identifier of the Area from which the LSA was received.E" REFERENCE "OSPF Version 2, Appendix C.2 Area parameters." ::= { axrOspfv3AreaLsdbEntry 2 } axrOspfv3AreaLsdbType OBJECT-TYPE SYNTAX INTEGER { routerLsa (8193), -- 0x2001 networkLsa (8194), -- 0x2002 interAreaPrefixLsa (8195), -- 0x2003 interAreaRouterLsa (8196), -- 0x2004 groupMembershipLsa (8198), -- 0x2006 nssaExternalLsa (8199), -- 0x2007 intraAreaPrefixLsa (8201) -- 0x2009 } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the link state advertisement. Each link state type has a separate advertise- ment format. Unrecognized Area-Scope LSAs with the U-bit set are also stored in this database." ::= { axrOspfv3AreaLsdbEntry 3 } axrOspfv3AreaLsdbRouterId OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "The 32 bit number that uniquely identifies the originating router in the Autonomous System." REFERENCE "OSPF Version 2, Appendix C.1 Global parameters" ::= { axrOspfv3AreaLsdbEntry 4 } axrOspfv3AreaLsdbLsid OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Link State ID is an LS Type Specific field containing either a Router ID or a unique identifier; it identifies the piece of the routing domain that is being described by the advertisement. In contrast to OSPF for IPv4, the LSID has no addressing semantics." ::= { axrOspfv3AreaLsdbEntry 5 } -- Note that the OSPF Sequence Number is a 32 bit signed -- integer. It starts with the value '80000001'h, -- or -'7FFFFFFF'h, and increments until '7FFFFFFF'h -- Thus, a typical sequence number will be very negative. axrOspfv3AreaLsdbSequence OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number field is a signed 32-bit integer. It is used to detect old and dupli- cate link state advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number the more recent the advertisement." REFERENCE "OSPF Version 2, Section 12.1.6 LS sequence number" ::= { axrOspfv3AreaLsdbEntry 6 } axrOspfv3AreaLsdbAge OBJECT-TYPE SYNTAX Integer32 -- Should be 0..MaxAge ACCESS read-only STATUS mandatory DESCRIPTION "This field is the age of the link state adver- tisement in seconds." REFERENCE "OSPF Version 2, Section 12.1.1 LS age" ::= { axrOspfv3AreaLsdbEntry 7 } axrOspfv3AreaLsdbChecksum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connec- tionless datagrams; it is commonly referred to as the Fletcher checksum." REFERENCE "OSPF Version 2, Section 12.1.7 LS checksum" ::= { axrOspfv3AreaLsdbEntry 8 } axrOspfv3AreaLsdbAdvertisement OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..65535)) ACCESS read-only STATUS mandatory DESCRIPTION "The entire Link State Advertisement, including its header." ::= { axrOspfv3AreaLsdbEntry 9 } -- axrOspfv3 Link-Scope Link State Database -- The Link State Database contains the Link-Scope Link State -- Advertisements from the links that the -- device is attached to. axrOspfv3LinkLsdbTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3LinkLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The axrOspfv3 Process's Link-Scope Link State Database." ::= { axrOspfv3 5 } axrOspfv3LinkLsdbEntry OBJECT-TYPE SYNTAX AxrOspfv3LinkLsdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single Link-Scope Link State Advertisement." INDEX { axrOspfv3LinkLsdbIfIndex, axrOspfv3LinkLsdbType, axrOspfv3LinkLsdbRouterId, axrOspfv3LinkLsdbLsid } ::= { axrOspfv3LinkLsdbTable 1 } AxrOspfv3LinkLsdbEntry ::= SEQUENCE { axrOspfv3LinkLsdbDomainNumber INTEGER, axrOspfv3LinkLsdbIfIndex Ipv6IfIndex, axrOspfv3LinkLsdbType INTEGER, axrOspfv3LinkLsdbRouterId RouterID, axrOspfv3LinkLsdbLsid IpAddress, axrOspfv3LinkLsdbSequence Integer32, axrOspfv3LinkLsdbAge Integer32, axrOspfv3LinkLsdbChecksum Integer32, axrOspfv3LinkLsdbAdvertisement OCTET STRING } axrOspfv3LinkLsdbDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3LinkLsdbEntry 1 } axrOspfv3LinkLsdbIfIndex OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The identifier of the link from which the LSA was received." REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" ::= { axrOspfv3LinkLsdbEntry 2 } axrOspfv3LinkLsdbType OBJECT-TYPE SYNTAX INTEGER { linkLsa (8) -- 0x0008 } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the link state advertisement. Each link state type has a separate advertise- ment format. Unrecognized Link-Scope LSAs with the U-bit set are also stored in this database." ::= { axrOspfv3LinkLsdbEntry 3 } axrOspfv3LinkLsdbRouterId OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "The 32 bit number that uniquely identifies the originating router in the Autonomous System." REFERENCE "OSPF Version 2, Appendix C.1 Global parameters" ::= { axrOspfv3LinkLsdbEntry 4 } axrOspfv3LinkLsdbLsid OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Link State ID is an LS Type Specific field containing either a Router ID or a unique identifier; it identifies the piece of the routing domain that is being described by the advertisement. In contrast to OSPF for IPv4, the LSID has no addressing semantics." ::= { axrOspfv3LinkLsdbEntry 5 } -- Note that the OSPF Sequence Number is a 32 bit signed -- integer. It starts with the value '80000001'h, -- or -'7FFFFFFF'h, and increments until '7FFFFFFF'h -- Thus, a typical sequence number will be very negative. axrOspfv3LinkLsdbSequence OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The sequence number field is a signed 32-bit integer. It is used to detect old and dupli- cate link state advertisements. The space of sequence numbers is linearly ordered. The larger the sequence number the more recent the advertisement." REFERENCE "OSPF Version 2, Section 12.1.6 LS sequence number" ::= { axrOspfv3LinkLsdbEntry 6 } axrOspfv3LinkLsdbAge OBJECT-TYPE SYNTAX Integer32 -- Should be 0..MaxAge ACCESS read-only STATUS mandatory DESCRIPTION "This field is the age of the link state adver- tisement in seconds." REFERENCE "OSPF Version 2, Section 12.1.1 LS age" ::= { axrOspfv3LinkLsdbEntry 7 } axrOspfv3LinkLsdbChecksum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "This field is the checksum of the complete contents of the advertisement, excepting the age field. The age field is excepted so that an advertisement's age can be incremented without updating the checksum. The checksum used is the same that is used for ISO connec- tionless datagrams; it is commonly referred to as the Fletcher checksum." REFERENCE "OSPF Version 2, Section 12.1.7 LS checksum" ::= { axrOspfv3LinkLsdbEntry 8 } axrOspfv3LinkLsdbAdvertisement OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..65535)) ACCESS read-only STATUS mandatory DESCRIPTION "The entire Link State Advertisement, including its header." ::= { axrOspfv3LinkLsdbEntry 9 } -- OSPF Host Table -- The Host/Metric Table indicates what hosts are directly -- attached to the Router, and what metrics and types of -- service should be advertised for them. -- axrOspfv3 Interface Table axrOspfv3IfTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The axrOspfv3 Interface Table describes the inter- faces from the viewpoint of axrOspfv3." REFERENCE "OSPF Version 2, Appendix C.3 Router interface parameters" ::= { axrOspfv3 7 } axrOspfv3IfEntry OBJECT-TYPE SYNTAX AxrOspfv3IfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The axrOspfv3 Interface Entry describes one inter- face from the viewpoint of axrOspfv3." INDEX { axrOspfv3IfIndex } ::= { axrOspfv3IfTable 1 } AxrOspfv3IfEntry ::= SEQUENCE { axrOspfv3IfDomainNumber INTEGER, axrOspfv3IfIndex Ipv6IfIndex, axrOspfv3IfAreaId AreaID, axrOspfv3IfType INTEGER, axrOspfv3IfAdminStat Status, axrOspfv3IfRtrPriority DesignatedRouterPriority, axrOspfv3IfTransitDelay UpToMaxAge, axrOspfv3IfRetransInterval UpToMaxAge, axrOspfv3IfHelloInterval HelloRange, axrOspfv3IfRtrDeadInterval PositiveInteger, axrOspfv3IfPollInterval PositiveInteger, axrOspfv3IfState INTEGER, axrOspfv3IfDesignatedRouter RouterID, axrOspfv3IfBackupDesignatedRouter RouterID, axrOspfv3IfEvents Counter32, axrOspfv3IfStatus RowStatus, axrOspfv3IfMulticastForwarding INTEGER, axrOspfv3IfDemand TruthValue, axrOspfv3IfMetricValue Metric, axrOspfv3IfLinkScopeLsaCount Gauge32, axrOspfv3IfLinkLsaCksumSum Integer32, axrOspfv3IfInstId Integer32 } axrOspfv3IfDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3IfEntry 1 } axrOspfv3IfIndex OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The interface index of this axrOspfv3 interface. It corresponds to the interface index of the Ipv6 interface on which axrOspfv3 is configured." ::= { axrOspfv3IfEntry 2 } axrOspfv3IfAreaId OBJECT-TYPE SYNTAX AreaID ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit integer uniquely identifying the area to which the interface connects. Area ID 0.0.0.0 is used for the axrOspfv3 backbone." DEFVAL { '00000000'H } -- 0.0.0.0 ::= { axrOspfv3IfEntry 3 } axrOspfv3IfType OBJECT-TYPE SYNTAX INTEGER { broadcast (1), nbma (2), pointToPoint (3), pointToMultipoint (5) } ACCESS read-only STATUS mandatory DESCRIPTION "The axrOspfv3 interface type." ::= { axrOspfv3IfEntry 4 } axrOspfv3IfAdminStat OBJECT-TYPE SYNTAX Status ACCESS read-only STATUS mandatory DESCRIPTION "The axrOspfv3 interface's administrative status. The value formed on the interface, and the in- terface will be advertised as an internal route to some area. The value 'disabled' denotes that the interface is external to axrOspfv3." DEFVAL { enabled } ::= { axrOspfv3IfEntry 5 } axrOspfv3IfRtrPriority OBJECT-TYPE SYNTAX DesignatedRouterPriority ACCESS read-only STATUS mandatory DESCRIPTION "The priority of this interface. Used in multi-access networks, this field is used in the designated router election algorithm. The value 0 signifies that the router is not eligi- ble to become the designated router on this particular network. In the event of a tie in this value, routers will use their Router ID as a tie breaker." DEFVAL { 1 } ::= { axrOspfv3IfEntry 6 } axrOspfv3IfTransitDelay OBJECT-TYPE SYNTAX UpToMaxAge ACCESS read-only STATUS mandatory DESCRIPTION "The estimated number of seconds it takes to transmit a link state update packet over this interface." DEFVAL { 1 } ::= { axrOspfv3IfEntry 7 } axrOspfv3IfRetransInterval OBJECT-TYPE SYNTAX UpToMaxAge ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds between link-state ad- vertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database descrip- tion and link-state request packets." DEFVAL { 5 } ::= { axrOspfv3IfEntry 8 } axrOspfv3IfHelloInterval OBJECT-TYPE SYNTAX HelloRange ACCESS read-only STATUS mandatory DESCRIPTION "The length of time, in seconds, between the Hello packets that the router sends on the in- terface. This value must be the same for all routers attached to a common network." DEFVAL { 10 } ::= { axrOspfv3IfEntry 9 } axrOspfv3IfRtrDeadInterval OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a router's Hello packets have not been seen before it's neigh- bors declare the router down. This should be some multiple of the Hello interval. This value must be the same for all routers attached to a common network." DEFVAL { 40 } ::= { axrOspfv3IfEntry 10 } axrOspfv3IfPollInterval OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The larger time interval, in seconds, between the Hello packets sent to an inactive non- broadcast multi- access neighbor." DEFVAL { 120 } ::= { axrOspfv3IfEntry 11 } axrOspfv3IfState OBJECT-TYPE SYNTAX INTEGER { down (1), loopback (2), waiting (3), pointToPoint (4), designatedRouter (5), backupDesignatedRouter (6), otherDesignatedRouter (7) } ACCESS read-only STATUS mandatory DESCRIPTION "The axrOspfv3 Interface State." DEFVAL { down } ::= { axrOspfv3IfEntry 12 } axrOspfv3IfDesignatedRouter OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "The Router ID of the Designated Router." DEFVAL { '00000000'H } -- 0.0.0.0 ::= { axrOspfv3IfEntry 13 } axrOspfv3IfBackupDesignatedRouter OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "The Router ID of the Backup Designated Router." DEFVAL { '00000000'H } -- 0.0.0.0 ::= { axrOspfv3IfEntry 15 } axrOspfv3IfEvents OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this OSPF interface has changed its state, or an error has occurred." ::= { axrOspfv3IfEntry 16 } axrOspfv3IfStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the en- try. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent." ::= { axrOspfv3IfEntry 18 } axrOspfv3IfMulticastForwarding OBJECT-TYPE SYNTAX INTEGER { blocked (1), -- no multicast forwarding multicast (2), -- using multicast address unicast (3) -- to each axrOspfv3 neighbor } ACCESS read-only STATUS mandatory DESCRIPTION "The way multicasts should forwarded on this interface; not forwarded, forwarded as data link multicasts, or forwarded as data link uni- casts. Data link multicasting is not meaning- ful on point to point and NBMA interfaces, and setting axrOspfv3MulticastForwarding to 0 effective- ly disables all multicast forwarding." DEFVAL { blocked } ::= { axrOspfv3IfEntry 19 } axrOspfv3IfDemand OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether Demand axrOspfv3 procedures (hel- lo supression to FULL neighbors and setting the DoNotAge flag on proogated LSAs) should be per- formed on this interface." DEFVAL { false } ::= { axrOspfv3IfEntry 20 } axrOspfv3IfMetricValue OBJECT-TYPE SYNTAX Metric ACCESS read-only STATUS mandatory DESCRIPTION "The metric assigned to this interface. The default value of the Metric is 10^8 / ifSpeed." ::= { axrOspfv3IfEntry 21 } axrOspfv3IfLinkScopeLsaCount OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Link-Scope link-state advertisements in this link's link-state database." ::= { axrOspfv3IfEntry 22 } axrOspfv3IfLinkLsaCksumSum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The 32-bit unsigned sum of the Link-Scope link-state advertisements' LS checksums contained in this link's link-state database. The sum can be used to determine if there has been a change in a router's link state database, and to compare the link-state database of two routers." DEFVAL { 0 } ::= { axrOspfv3IfEntry 23 } axrOspfv3IfInstId OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "Enables multiple instances of axrOspfv3 to be run over a single link. Each protocol instance would be assigned a separate ID. This ID has local link significance only." DEFVAL { 0 } ::= { axrOspfv3IfEntry 24 } -- axrOspfv3 Virtual Interface Table -- The Virtual Interface Table describes the virtual -- links that the axrOspfv3 Process is configured to -- carry on. axrOspfv3VirtIfTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3VirtIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about this router's virtual inter- faces." REFERENCE "OSPF Version 2, Appendix C.4 Virtual link parameters" ::= { axrOspfv3 8 } axrOspfv3VirtIfEntry OBJECT-TYPE SYNTAX AxrOspfv3VirtIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information about a single Virtual Interface." INDEX { axrOspfv3VirtIfAreaId, axrOspfv3VirtIfNeighbor } ::= { axrOspfv3VirtIfTable 1 } AxrOspfv3VirtIfEntry ::= SEQUENCE { axrOspfv3VirtIfDomainNumber INTEGER, axrOspfv3VirtIfAreaId AreaID, axrOspfv3VirtIfNeighbor RouterID, axrOspfv3VirtIfIndex Ipv6IfIndex, axrOspfv3VirtIfTransitDelay UpToMaxAge, axrOspfv3VirtIfRetransInterval UpToMaxAge, axrOspfv3VirtIfHelloInterval HelloRange, axrOspfv3VirtIfRtrDeadInterval PositiveInteger, axrOspfv3VirtIfState INTEGER, axrOspfv3VirtIfEvents Counter32, axrOspfv3VirtIfStatus RowStatus, axrOspfv3VirtIfLinkScopeLsaCount Gauge32, axrOspfv3VirtIfLinkLsaCksumSum Integer32 } axrOspfv3VirtIfDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3VirtIfEntry 1 } axrOspfv3VirtIfAreaId OBJECT-TYPE SYNTAX AreaID ACCESS read-only STATUS mandatory DESCRIPTION "The Transit Area that the Virtual Link traverses. By definition, this is not 0.0.0.0" ::= { axrOspfv3VirtIfEntry 2 } axrOspfv3VirtIfNeighbor OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "The Router ID of the Virtual Neighbor." ::= { axrOspfv3VirtIfEntry 3 } axrOspfv3VirtIfIndex OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The interface index of this axrOspfv3 virtual interface. It must be unique among all the interface indices on the router." ::= { axrOspfv3VirtIfEntry 4 } axrOspfv3VirtIfTransitDelay OBJECT-TYPE SYNTAX UpToMaxAge ACCESS read-only STATUS mandatory DESCRIPTION "The estimated number of seconds it takes to transmit a link- state update packet over this interface." DEFVAL { 1 } ::= { axrOspfv3VirtIfEntry 5 } axrOspfv3VirtIfRetransInterval OBJECT-TYPE SYNTAX UpToMaxAge ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds between link-state ad- vertisement retransmissions, for adjacencies belonging to this interface. This value is also used when retransmitting database descrip- tion and link-state request packets. This value should be well over the expected round- trip time." DEFVAL { 5 } ::= { axrOspfv3VirtIfEntry 6 } axrOspfv3VirtIfHelloInterval OBJECT-TYPE SYNTAX HelloRange ACCESS read-only STATUS mandatory DESCRIPTION "The length of time, in seconds, between the Hello packets that the router sends on the in- terface. This value must be the same for the virtual neighbor." DEFVAL { 10 } ::= { axrOspfv3VirtIfEntry 7 } axrOspfv3VirtIfRtrDeadInterval OBJECT-TYPE SYNTAX PositiveInteger ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds that a router's Hello packets have not been seen before it's neigh- bors declare the router down. This should be some multiple of the Hello interval. This value must be the same for the virtual neigh- bor." DEFVAL { 60 } ::= { axrOspfv3VirtIfEntry 8 } axrOspfv3VirtIfState OBJECT-TYPE SYNTAX INTEGER { down (1), -- these use the same encoding pointToPoint (4) -- as the axrOspfv3IfTable } ACCESS read-only STATUS mandatory DESCRIPTION "OSPF virtual interface states." DEFVAL { down } ::= { axrOspfv3VirtIfEntry 9 } axrOspfv3VirtIfEvents OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of state changes or error events on this Virtual Link" ::= { axrOspfv3VirtIfEntry 10 } axrOspfv3VirtIfStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the en- try. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent." ::= { axrOspfv3VirtIfEntry 11 } axrOspfv3VirtIfLinkScopeLsaCount OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Link-Scope link-state advertisements in this virtual link's link-state database." ::= { axrOspfv3VirtIfEntry 12 } axrOspfv3VirtIfLinkLsaCksumSum OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The 32-bit unsigned sum of the Link-Scope link-state advertisements' LS checksums contained in this virtual link's link-state database. The sum can be used to determine if there has been a change in a router's link state database, and to compare the link-state database of two routers." DEFVAL { 0 } ::= { axrOspfv3VirtIfEntry 13 } -- axrOspfv3 Neighbor Table -- The axrOspfv3 Neighbor Table describes all neighbors in -- the locality of the subject router. axrOspfv3NbrTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3NbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of non-virtual neighbor information." REFERENCE "OSPF Version 2, Section 10 The Neighbor Data Structure" ::= { axrOspfv3 9 } axrOspfv3NbrEntry OBJECT-TYPE SYNTAX AxrOspfv3NbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The information regarding a single neighbor." REFERENCE "OSPF Version 2, Section 10 The Neighbor Data Structure" INDEX { axrOspfv3NbrIfIndex, axrOspfv3NbrIpv6Addr } ::= { axrOspfv3NbrTable 1 } AxrOspfv3NbrEntry ::= SEQUENCE { axrOspfv3NbrDomainNumber INTEGER, axrOspfv3NbrIfIndex Ipv6IfIndex, axrOspfv3NbrIpv6Addr Ipv6Address, axrOspfv3NbrRtrId RouterID, axrOspfv3NbrOptions Integer32, axrOspfv3NbrPriority DesignatedRouterPriority, axrOspfv3NbrState INTEGER, axrOspfv3NbrEvents Counter32, axrOspfv3NbrLsRetransQLen Gauge32, -- axrOspfv3NbmaNbrStatus -- RowStatus, -- axrOspfv3NbmaNbrPermanence -- INTEGER, axrOspfv3NbrHelloSuppressed TruthValue, axrOspfv3NbrIfId Ipv6IfIndex } axrOspfv3NbrDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3NbrEntry 1 } axrOspfv3NbrIfIndex OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The local link ID of the link over which the neighbor can be reached." ::= { axrOspfv3NbrEntry 2 } axrOspfv3NbrIpv6Addr OBJECT-TYPE SYNTAX Ipv6Address ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 address of the neighbor associated with the local link." ::= { axrOspfv3NbrEntry 3 } axrOspfv3NbrRtrId OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit integer (represented as a type IpAd- dress) uniquely identifying the neighboring router in the Autonomous System." ::= { axrOspfv3NbrEntry 4 } axrOspfv3NbrOptions OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "A Bit Mask corresponding to the neighbor's op- tions field." DEFVAL { 0 } ::= { axrOspfv3NbrEntry 5 } axrOspfv3NbrPriority OBJECT-TYPE SYNTAX DesignatedRouterPriority ACCESS read-only STATUS mandatory DESCRIPTION "The priority of this neighbor in the designat- ed router election algorithm. The value 0 sig- nifies that the neighbor is not eligible to be- come the designated router on this particular network." DEFVAL { 1 } ::= { axrOspfv3NbrEntry 6 } axrOspfv3NbrState OBJECT-TYPE SYNTAX INTEGER { down (1), attempt (2), init (3), twoWay (4), exchangeStart (5), exchange (6), loading (7), full (8) } ACCESS read-only STATUS mandatory DESCRIPTION "The State of the relationship with this Neigh- bor." REFERENCE "OSPF Version 2, Section 10.1 Neighbor States" DEFVAL { down } ::= { axrOspfv3NbrEntry 7 } axrOspfv3NbrEvents OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this neighbor relationship has changed state, or an error has occurred." ::= { axrOspfv3NbrEntry 8 } axrOspfv3NbrLsRetransQLen OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The current length of the retransmission queue." ::= { axrOspfv3NbrEntry 9 } axrOspfv3NbrHelloSuppressed OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether Hellos are being suppressed to the neighbor" ::= { axrOspfv3NbrEntry 12 } axrOspfv3NbrIfId OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The interface ID that the neighbor advertises in its Hello Packets on this link, that is, the neighbor's local interface index." ::= { axrOspfv3NbrEntry 13 } -- axrOspfv3 Virtual Neighbor Table -- This table describes all virtual neighbors. -- Since Virtual Links are configured in the -- virtual interface table, this table is read-only. axrOspfv3VirtNbrTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3VirtNbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of virtual neighbor information." REFERENCE "OSPF Version 2, Section 15 Virtual Links" ::= { axrOspfv3 10 } axrOspfv3VirtNbrEntry OBJECT-TYPE SYNTAX AxrOspfv3VirtNbrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Virtual neighbor information." INDEX { axrOspfv3VirtNbrArea, axrOspfv3VirtNbrRtrId } ::= { axrOspfv3VirtNbrTable 1 } AxrOspfv3VirtNbrEntry ::= SEQUENCE { axrOspfv3VirtNbrDomainNumber INTEGER, axrOspfv3VirtNbrArea AreaID, axrOspfv3VirtNbrRtrId RouterID, axrOspfv3VirtNbrIfIndex Ipv6IfIndex, axrOspfv3VirtNbrIpv6Addr Ipv6Address, axrOspfv3VirtNbrOptions Integer32, axrOspfv3VirtNbrState INTEGER, axrOspfv3VirtNbrEvents Counter32, axrOspfv3VirtNbrLsRetransQLen Gauge32, axrOspfv3VirtNbrHelloSuppressed TruthValue, axrOspfv3VirtNbrIfId Ipv6IfIndex } axrOspfv3VirtNbrDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3VirtNbrEntry 1 } axrOspfv3VirtNbrArea OBJECT-TYPE SYNTAX AreaID ACCESS read-only STATUS mandatory DESCRIPTION "The Transit Area Identifier." ::= { axrOspfv3VirtNbrEntry 2 } axrOspfv3VirtNbrRtrId OBJECT-TYPE SYNTAX RouterID ACCESS read-only STATUS mandatory DESCRIPTION "A 32-bit integer uniquely identifying the neighboring router in the Autonomous System." ::= { axrOspfv3VirtNbrEntry 3 } axrOspfv3VirtNbrIfIndex OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The local link ID for the virtual link over which the neighbor can be reached." ::= { axrOspfv3VirtNbrEntry 4 } axrOspfv3VirtNbrIpv6Addr OBJECT-TYPE SYNTAX Ipv6Address ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 address used to reach this Virtual Neighbor. It must be a Site-Local or Global scope address." ::= { axrOspfv3VirtNbrEntry 5 } axrOspfv3VirtNbrOptions OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "A Bit Mask corresponding to the neighbor's op- tions field." ::= { axrOspfv3VirtNbrEntry 6 } axrOspfv3VirtNbrState OBJECT-TYPE SYNTAX INTEGER { down (1), attempt (2), init (3), twoWay (4), exchangeStart (5), exchange (6), loading (7), full (8) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of the Virtual Neighbor Relation- ship." ::= { axrOspfv3VirtNbrEntry 7 } axrOspfv3VirtNbrEvents OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this virtual link has changed its state, or an error has occurred." ::= { axrOspfv3VirtNbrEntry 8 } axrOspfv3VirtNbrLsRetransQLen OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The current length of the retransmission queue." ::= { axrOspfv3VirtNbrEntry 9 } axrOspfv3VirtNbrHelloSuppressed OBJECT-TYPE SYNTAX TruthValue ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether Hellos are being suppressed to the neighbor" ::= { axrOspfv3VirtNbrEntry 10 } axrOspfv3VirtNbrIfId OBJECT-TYPE SYNTAX Ipv6IfIndex ACCESS read-only STATUS mandatory DESCRIPTION "The interface ID that the neighbor advertises in its Hello Packets on this virtual link, that is, the neighbor's local interface index." ::= { axrOspfv3VirtNbrEntry 11 } -- -- The axrOspfv3 Area Aggregate Table -- axrOspfv3AreaAggregateTable OBJECT-TYPE SYNTAX SEQUENCE OF AxrOspfv3AreaAggregateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A range of IPv6 prefixes specified by a prefix/prefix length pair. Note that if ranges are configured such that one range sub- sumes another range the most specific match is the preferred one." ::= { axrOspfv3 11 } axrOspfv3AreaAggregateEntry OBJECT-TYPE SYNTAX AxrOspfv3AreaAggregateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A range of IPv6 prefixes specified by a prefix/prefix length pair. Note that if ranges are configured such that one range sub- sumes another range the most specific match is the preferred one." REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" INDEX { axrOspfv3AreaAggregateAreaID, axrOspfv3AreaAggregateAreaLsdbType, axrOspfv3AreaAggregateIndex } ::= { axrOspfv3AreaAggregateTable 1 } AxrOspfv3AreaAggregateEntry ::= SEQUENCE { axrOspfv3AreaAggregateDomainNumber INTEGER, axrOspfv3AreaAggregateAreaID AreaID, axrOspfv3AreaAggregateAreaLsdbType INTEGER, axrOspfv3AreaAggregateIndex INTEGER, axrOspfv3AreaAggregatePrefix Ipv6AddressPrefix, axrOspfv3AreaAggregatePrefixLen INTEGER, axrOspfv3AreaAggregateStatus RowStatus, axrOspfv3AreaAggregateEffect INTEGER } axrOspfv3AreaAggregateDomainNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "ospfv3 domain number." ::= { axrOspfv3AreaAggregateEntry 1 } axrOspfv3AreaAggregateAreaID OBJECT-TYPE SYNTAX AreaID ACCESS read-only STATUS mandatory DESCRIPTION "The Area the Address Aggregate is to be found within." REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" ::= { axrOspfv3AreaAggregateEntry 2 } axrOspfv3AreaAggregateAreaLsdbType OBJECT-TYPE SYNTAX INTEGER { interAreaPrefixLsa (8195), -- 0x2003 nssaExternalLsa (8199) -- 0x2007 } ACCESS read-only STATUS mandatory DESCRIPTION "The type of the Address Aggregate. This field specifies the Area Lsdb type that this Address Ag- axregate applies to." REFERENCE "OSPF Version 2, Appendix A.4.1 The Link State Advertisement header" ::= { axrOspfv3AreaAggregateEntry 3 } axrOspfv3AreaAggregateIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier for this aggregate table entry." ::= { axrOspfv3AreaAggregateEntry 4 } axrOspfv3AreaAggregatePrefix OBJECT-TYPE SYNTAX Ipv6AddressPrefix ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 Prefix." REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" ::= { axrOspfv3AreaAggregateEntry 5 } axrOspfv3AreaAggregatePrefixLen OBJECT-TYPE SYNTAX INTEGER ( 3..128 ) -- UNITS "bits" ACCESS read-only STATUS mandatory DESCRIPTION "The length of the prefix (in bits). A prefix can not be shorter than 3 bits." REFERENCE "OSPF Version 2, Appendix C.2 Area parameters" ::= { axrOspfv3AreaAggregateEntry 6 } axrOspfv3AreaAggregateStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable displays the status of the en- try. Setting it to 'invalid' has the effect of rendering it inoperative. The internal effect (row removal) is implementation dependent." ::= { axrOspfv3AreaAggregateEntry 7 } axrOspfv3AreaAggregateEffect OBJECT-TYPE SYNTAX INTEGER { advertiseMatching (1), doNotAdvertiseMatching (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Prefixes subsumed by ranges either trigger the advertisement of the indicated aggregate (ad- vertiseMatching), or result in the prefix not being advertised at all outside the area." DEFVAL { advertiseMatching } ::= { axrOspfv3AreaAggregateEntry 8 } -- ax2000rRouter group ax2000rModelType OBJECT-TYPE SYNTAX INTEGER { other(1), model4(2), model10(3), model20(4), model2S(11), model4S(12), model6H(13), model10H(14), model20H(15), model1B(21), model2B(22), modelBH(23) } ACCESS read-only STATUS mandatory DESCRIPTION "Model type of this system." ::= { ax2000rRouter 1 } --ax2000rSoftware OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "Software information of this system." -- ::= { ax2000rRouter 2 } ax2000rSoftwareName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Software name of this system." ::= { ax2000rSoftware 1 } ax2000rSoftwareAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "System software abbreviation." ::= { ax2000rSoftware 2 } ax2000rSoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "System software version." ::= { ax2000rSoftware 3 } --ax2000rSystemMsg OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "System messege group." -- ::= { ax2000rRouter 3 } ax2000rSystemMsgText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..256)) ACCESS read-only STATUS mandatory DESCRIPTION "The text of the system log message.For information about this code, see: Operator's Manual. " ::= { ax2000rSystemMsg 1 } ax2000rSystemMsgType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-only STATUS mandatory DESCRIPTION "The event type. For information about this code, see: Operator's Manual." ::= { ax2000rSystemMsg 2 } ax2000rSystemMsgTimeStamp OBJECT-TYPE SYNTAX DisplayString (SIZE (14)) ACCESS read-only STATUS mandatory DESCRIPTION "The time that event occured. And that is expressed as type of MM/DD hh:mm:ss MM:month(01-12) DD:day(01-31) hh:hour(00-23) mm:minute(00-59) ss:second(00-59) Insert space between DD and hh." ::= { ax2000rSystemMsg 3 } ax2000rSystemMsgLevel OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-only STATUS mandatory DESCRIPTION "The newest system message log level.For information about this code, see: Operator's Manual. " ::= { ax2000rSystemMsg 4 } ax2000rSystemMsgEventPoint OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The code of part that system message error occured. For information about this code,see: Operator's Manual. " ::= { ax2000rSystemMsg 5 } ax2000rSystemMsgEventInterfaceID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Interface identification of system messages. For information about this code,see: Operator's Manual." ::= { ax2000rSystemMsg 6 } ax2000rSystemMsgEventCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "Event kind code of system messages. For information about this code, see: Operator's Manual. " ::= { ax2000rSystemMsg 7 } ax2000rSystemMsgAdditionalCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) ACCESS read-only STATUS mandatory DESCRIPTION "Additional code of system messages. For information about this code, see: Operator's Manual. " ::= { ax2000rSystemMsg 8 } --ax2000rSnmpAgent OBJECT-TYPE -- SYNTAX INTEGER -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "Related information of SNMP agent." -- ::= { ax2000rRouter 4 } ax2000rSnmpSendReceiveSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SNMP packet data size in Manager-to-Agent communication. The value is displayed in bytes." ::= { ax2000rSnmpAgent 1 } ax2000rSnmpReceiveDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A recommendable interval to receive packets from Manager.The value is displayed in milliseconds." ::= { ax2000rSnmpAgent 2 } ax2000rSnmpContinuousSend OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times that is recommendable continuous transmission packets." ::= { ax2000rSnmpAgent 3 } ax2000rSnmpObjectMaxNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max number of objects that contain SNMP packet." ::= { ax2000rSnmpAgent 4 } ax2000rSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Management information (SerialNumber) of RMP2-CARD." ::= { ax2000rRouter 5 } -- ax2000rDevice group ax2000rChassisMaxNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Max number of cluster chassis that can connect to this router." ::= { ax2000rChassis 1 } ax2000rChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rChassisTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing chassis information." ::= { ax2000rChassis 2 } ax2000rChassisEntry OBJECT-TYPE SYNTAX Ax2000rChassisTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing specific chassis." INDEX { ax2000rChassisIndex } ::= { ax2000rChassisTable 1 } Ax2000rChassisTableEntry ::= SEQUENCE { ax2000rChassisIndex INTEGER, ax2000rChassisType INTEGER, ax2000rChassisStatus INTEGER, ax2000rRmBoardDuplexMode INTEGER, ax2000rPowerUnitNumber INTEGER, ax2000rFanNumber INTEGER, ax2000rCifNumber INTEGER, ax2000rRmBoardNumber INTEGER, ax2000rRpBoardNumber INTEGER, ax2000rNifBoardNumber INTEGER, ax2000rCswNumber INTEGER, ax2000rPsInputNumber INTEGER } ax2000rChassisIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "A number to specify ax2000rChassisEntry." ::= { ax2000rChassisEntry 1 } ax2000rChassisType OBJECT-TYPE SYNTAX INTEGER { other(1), model4(2), model10(3), model20(4), model2S(11), model4S(12), model6H(13), model10H(14), model20H(15), model1B(21), model2B(22), modelBH(23) } ACCESS read-only STATUS mandatory DESCRIPTION "Chassis type of this system." ::= { ax2000rChassisEntry 2 } ax2000rChassisStatus OBJECT-TYPE SYNTAX INTEGER { up(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Current status of this chassis." ::= { ax2000rChassisEntry 3 } ax2000rRmBoardDuplexMode OBJECT-TYPE SYNTAX INTEGER { rm-Simplex-model(1), rm-Duplex-model(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Duplex mode of RM Board." ::= { ax2000rChassisEntry 4 } ax2000rPowerUnitNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of maximum power switches that this router can connect its." ::= { ax2000rChassisEntry 5 } ax2000rFanNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of fans that can connect to this chassis." ::= { ax2000rChassisEntry 6 } ax2000rCifNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of cluster interfaces that can connect to this chassis." ::= { ax2000rChassisEntry 7 } ax2000rRmBoardNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of RM(Routing Manager) boards that can connect to this chassis." ::= { ax2000rChassisEntry 8 } ax2000rRpBoardNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of RP(Routing Processor) boards that can connect to this chassis." ::= { ax2000rChassisEntry 9 } ax2000rNifBoardNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of NIF(Network InterFace) boards that can connect to this chassis." ::= { ax2000rChassisEntry 10 } ax2000rCswNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of CSW(Crossbar SWitch) that can load into this chassis." ::= { ax2000rChassisEntry 11 } ax2000rPsInputNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of PSINPUT that can connect to this chassis." ::= { ax2000rChassisEntry 12 } ax2000rPowerUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rPowerUnitTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing power unit information." ::= { ax2000rChassis 3 } ax2000rPowerUnitEntry OBJECT-TYPE SYNTAX Ax2000rPowerUnitTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing power unit information." INDEX { ax2000rChassisIndex,ax2000rPowerUnitIndex } ::= { ax2000rPowerUnitTable 1 } Ax2000rPowerUnitTableEntry ::= SEQUENCE { ax2000rPowerUnitIndex INTEGER, ax2000rPowerConnectStatus INTEGER, ax2000rPowerSupplyStatus INTEGER } ax2000rPowerUnitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "A number to position of the power units.The value from 1 to ax2000rPowerUnitNumber." ::= { ax2000rPowerUnitEntry 1 } ax2000rPowerConnectStatus OBJECT-TYPE SYNTAX INTEGER { connected(2), disconnected(32) } ACCESS read-only STATUS mandatory DESCRIPTION "The current connection status of the power unit." ::= { ax2000rPowerUnitEntry 2 } ax2000rPowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { ok(2), fault(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of power supply." ::= { ax2000rPowerUnitEntry 3 } ax2000rFanTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rFanTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing fan information." ::= { ax2000rChassis 4 } ax2000rFanEntry OBJECT-TYPE SYNTAX Ax2000rFanTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry containing information for a fan." INDEX { ax2000rChassisIndex,ax2000rFanIndex } ::= { ax2000rFanTable 1 } Ax2000rFanTableEntry ::= SEQUENCE { ax2000rFanIndex INTEGER, ax2000rFanStatus INTEGER } ax2000rFanIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Index to indicate position of fans." ::= { ax2000rFanEntry 1 } ax2000rFanStatus OBJECT-TYPE SYNTAX INTEGER { ok(2), fault(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of fans." ::= { ax2000rFanEntry 2 } ax2000rCswTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rCswTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing CSW(Crossbar SWitch) information." ::= { ax2000rChassis 5 } ax2000rCswEntry OBJECT-TYPE SYNTAX Ax2000rCswTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing CSW(Crossbar SWitch) information." INDEX { ax2000rChassisIndex,ax2000rCswIndex } ::= { ax2000rCswTable 1 } Ax2000rCswTableEntry ::= SEQUENCE { ax2000rCswIndex INTEGER, ax2000rCswStatus INTEGER } ax2000rCswIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An unique value indicates connecting position of CSWs.The value form 1 to ax2000rCswNumber." ::= { ax2000rCswEntry 1 } ax2000rCswStatus OBJECT-TYPE SYNTAX INTEGER { ok(2), fault(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Connecting status of CSW." ::= { ax2000rCswEntry 2 } ax2000rPsInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rPsInputTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing PSINPUT information." ::= { ax2000rChassis 6 } ax2000rPsInputEntry OBJECT-TYPE SYNTAX Ax2000rPsInputTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing PSINPUT information." INDEX { ax2000rChassisIndex,ax2000rPsInputIndex } ::= { ax2000rPsInputTable 1 } Ax2000rPsInputTableEntry ::= SEQUENCE { ax2000rPsInputIndex INTEGER, ax2000rPsInputType INTEGER, ax2000rPsInputConnectStatus INTEGER, ax2000rPsInputSupplyStatus INTEGER } ax2000rPsInputIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "An unique value indicates connecting position of PSINPUTs.The value from 1 to ax2000rPsInputNumber." ::= { ax2000rPsInputEntry 1 } ax2000rPsInputType OBJECT-TYPE SYNTAX INTEGER { ac100(1), ac200-or-dc48(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of the PSINPUT. The value is -1 when PSINPUT is disconnected." ::= { ax2000rPsInputEntry 2 } ax2000rPsInputConnectStatus OBJECT-TYPE SYNTAX INTEGER { connect(2), disconnect(32) } ACCESS read-only STATUS mandatory DESCRIPTION "The current connection status of the PSINPUT." ::= { ax2000rPsInputEntry 3 } ax2000rPsInputSupplyStatus OBJECT-TYPE SYNTAX INTEGER { ok(2), fault(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Connecting status of PSINPUT. The value is -1 when PSINPUT is disconnected." ::= { ax2000rPsInputEntry 4 } ax2000rRmBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rRmBoardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing RM(Routing Manager) boards information." ::= { ax2000rRmBoard 1 } ax2000rRmBoardEntry OBJECT-TYPE SYNTAX Ax2000rRmBoardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing RM(Routing Manager) boards about specific chassis." INDEX { ax2000rChassisIndex,ax2000rRmBoardIndex } ::= { ax2000rRmBoardTable 1 } Ax2000rRmBoardTableEntry ::= SEQUENCE { ax2000rRmBoardIndex INTEGER, ax2000rRmIoBoardType INTEGER, ax2000rRmCpuBoardType INTEGER, ax2000rRmOperStatus INTEGER, ax2000rRmOperModeStatus INTEGER, ax2000rRmActiveLedStatus INTEGER, ax2000rRmReadyLedStatus INTEGER, ax2000rRmAlarmLedStatus INTEGER, ax2000rRmErrorLedStatus INTEGER, ax2000rRmEmaLedStatus INTEGER, ax2000rRmStatusCode INTEGER, ax2000rRmEthernetStatus INTEGER, ax2000rRmAtaCardNumber INTEGER, ax2000rRmAtaBootDev INTEGER, ax2000rRmBoardName DisplayString, ax2000rRmBoardAbbreviation DisplayString, ax2000rRmIoBoardProductCode INTEGER, ax2000rRmCpuBoardProductCode INTEGER, ax2000rRmCpuName DisplayString, ax2000rRmCpuClock INTEGER, ax2000rRmMemoryTotalSize INTEGER, ax2000rRmMemoryUsedSize INTEGER, ax2000rRmMemoryFreeSize INTEGER, ax2000rRmRomVersion DisplayString, ax2000rRmCpuLoad1m INTEGER, ax2000rRmTemperatureStatusNumber INTEGER } ax2000rRmBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Position information of the RM slot. The value is from 1 to ax2000rRmBoardCardNumber." ::= { ax2000rRmBoardEntry 1 } ax2000rRmIoBoardType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RM(Routing Manager) IO board ID. model2S/model4 RM-IO (4096) model10/model20 RM-IO (16781312) model4S RM-IO (16781568) model6H/model10H/model20H RM-IO (16781824) model6H/model10H/model20H RMB-IO(16782080) model4S RMB-IO (16782336) model1B/model2B RMBB-IO (10752) modelBH RMBH-IO (5888) The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 2 } ax2000rRmCpuBoardType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of RM board ID. RM(CPU) 0 (0x0000) RMB(CPU) 256 (0x0100) The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 3 } ax2000rRmOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), up(2), down(4), closed(5), disconnect(32) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of LED on RM board. The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 4 } ax2000rRmOperModeStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), standby(3), do-not-match-with-configure-mode(4), do-not-match-with-software-version(5), down(6), mentenance(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Operate status on RM board. The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 5 } ax2000rRmActiveLedStatus OBJECT-TYPE SYNTAX INTEGER { green-light-on(2), light-off(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of ACTIVE LED on RM board. The value is -1 when RM board is disconnected or LED status is unknown." ::= { ax2000rRmBoardEntry 6 } ax2000rRmReadyLedStatus OBJECT-TYPE SYNTAX INTEGER { green-light-on(2), light-off(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of READY LED on RM board. The value is -1 when RM board is disconnected or LED status is unknown." ::= { ax2000rRmBoardEntry 7 } ax2000rRmAlarmLedStatus OBJECT-TYPE SYNTAX INTEGER { red-light-on(4), light-off(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of ALARM LED on RM board. The value is -1 when RM board is disconnected or LED status is unknown." ::= { ax2000rRmBoardEntry 8 } ax2000rRmErrorLedStatus OBJECT-TYPE SYNTAX INTEGER { yellow-light-on(5), light-off(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of LED ERROR on RM board. The value is -1 when RM board is disconnected or LED status is unknown." ::= { ax2000rRmBoardEntry 9 } ax2000rRmEmaLedStatus OBJECT-TYPE SYNTAX INTEGER { yellow-light-on(5), light-off(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of LED EMA READY on RM board. The value is -1 when RM board is disconnected or LED status is unknown." ::= { ax2000rRmBoardEntry 10 } ax2000rRmStatusCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The status code of 7 segments on RM board.(00-99)" ::= { ax2000rRmBoardEntry 11 } ax2000rRmEthernetStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), down(4), nothing-configuration-or-locked(6), maintenance(7), test(9), unused(10), standby(12) } ACCESS read-only STATUS mandatory DESCRIPTION "Operaion status on RM ethernet. The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 12 } ax2000rRmAtaCardNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of slots in ATA card. The value is 0 when RM board is disconnected." ::= { ax2000rRmBoardEntry 13 } ax2000rRmAtaBootDev OBJECT-TYPE SYNTAX INTEGER { ata-slot0(1), ata-slot1(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of ATA slots number when router booted. The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 14 } ax2000rRmBoardName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The product name of RM-IO board.When RM board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRmBoardEntry 15 } ax2000rRmBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The abbreviation name of RM-IO board.When RM board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRmBoardEntry 16 } ax2000rRmIoBoardProductCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The manufacturing management number of RM-IO board.The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 17 } ax2000rRmCpuBoardProductCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The manufacturing management number of RM-CPU board.The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 18 } ax2000rRmCpuName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The CPU name of board that load RM.When RM board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRmBoardEntry 19 } ax2000rRmCpuClock OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The CPU clock of board that load RM. The value is displayed in mega-hertz(MHz). The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 20 } ax2000rRmMemoryTotalSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total memory sizes of RM. The value is displayed in kilobyte(KB). The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 21 } ax2000rRmMemoryUsedSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Using memory sizes of RM. The value is displayed in kilobyte(KB). The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 22 } ax2000rRmMemoryFreeSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Free memory sizes of RM. The value is displayed in kilobyte(KB). The value is -1 when RM board is disconnected." ::= { ax2000rRmBoardEntry 23 } ax2000rRmRomVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of Rom on RM board. When RM board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRmBoardEntry 24 } ax2000rRmCpuLoad1m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average, over the last minute, of the percentage of time that this processor was utilized to processing and transfer data. The value is -1 when RM board is standby or disconnected." ::= { ax2000rRmBoardEntry 25 } ax2000rRmTemperatureStatusNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of ax2000rTemperatureStatus that can be measurement at this chassis." ::= { ax2000rRmBoardEntry 26 } ax2000rAtaCardTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rAtaCardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing ATA Card information." ::= { ax2000rRmBoard 2 } ax2000rAtaCardEntry OBJECT-TYPE SYNTAX Ax2000rAtaCardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing ATA Card information." INDEX { ax2000rChassisIndex, ax2000rRmBoardIndex, ax2000rAtaCardIndex } ::= { ax2000rAtaCardTable 1 } Ax2000rAtaCardTableEntry ::= SEQUENCE { ax2000rAtaCardIndex INTEGER, ax2000rAtaCardConnection INTEGER, ax2000rAtaCardTotalSize INTEGER, ax2000rAtaCardUsedSize INTEGER, ax2000rAtaCardFreeSize INTEGER, ax2000rAtaCardName DisplayString, ax2000rAtaCardAbbreviation DisplayString, ax2000rAtaCardMountStatus INTEGER } ax2000rAtaCardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Connected position of ATA cards.The value is 1 plus slot number that ATA card is inserted.The value is from 1 to ax2000rRmAtaCardNumber." ::= { ax2000rAtaCardEntry 1 } ax2000rAtaCardConnection OBJECT-TYPE SYNTAX INTEGER { connect(2), disconnect(32) } ACCESS read-only STATUS mandatory DESCRIPTION "Connected status of ATA cards." ::= { ax2000rAtaCardEntry 2 } ax2000rAtaCardTotalSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total capacity of ATA cards.The value is displayed in kilobyte (kbyte).And the value is -1 when ATA cards is disconnected." ::= { ax2000rAtaCardEntry 3 } ax2000rAtaCardUsedSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Using capacity of ATA cards.The value is displayed in kilobyte (kbyte).And the value is -1 when ATA cards is disconnected." ::= { ax2000rAtaCardEntry 4 } ax2000rAtaCardFreeSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The rest capacity of ATA card. The value is displayed in kilobyte (kbyte). The value is -1 when ATA card is disconnected." ::= { ax2000rAtaCardEntry 5 } ax2000rAtaCardName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The product name of ATA card. When the ATA card is unknown, this OCTET STRING value is 'unknown'. When ATA card is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rAtaCardEntry 6 } ax2000rAtaCardAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The kind of ATA card. When ATA card is disconnected,this will be an OCTET STRING of zero length." ::= { ax2000rAtaCardEntry 7 } ax2000rAtaCardMountStatus OBJECT-TYPE SYNTAX INTEGER { unmount(1), mount(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The mount state of ATA card. The value is -1 when ATA card is disconnected." ::= { ax2000rAtaCardEntry 8 } ax2000rTemperatureStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rTemperatureStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table of ambient temperature status maintained by the environmental monitor." ::= { ax2000rRmBoard 3 } ax2000rTemperatureStatusEntry OBJECT-TYPE SYNTAX Ax2000rTemperatureStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ambient temperature status table, representing the status of the associated testpoint maintained by the environmental monitor." INDEX { ax2000rChassisIndex, ax2000rRmBoardIndex, ax2000rTemperatureStatusIndex } ::= { ax2000rTemperatureStatusTable 1 } Ax2000rTemperatureStatusEntry ::= SEQUENCE { ax2000rTemperatureStatusIndex INTEGER(0..2147483647), ax2000rTemperatureStatusDescr DisplayString, ax2000rTemperatureStatusValue Gauge, ax2000rTemperatureThreshold INTEGER, ax2000rTemperatureState INTEGER } ax2000rTemperatureStatusIndex OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS not-accessible STATUS mandatory DESCRIPTION "Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { ax2000rTemperatureStatusEntry 1 } ax2000rTemperatureStatusDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry." ::= { ax2000rTemperatureStatusEntry 2 } ax2000rTemperatureStatusValue OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The current measurement of the testpoint being instrumented." ::= { ax2000rTemperatureStatusEntry 3 } ax2000rTemperatureThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The highest value that the associated instance of the object ax2000rTemperatureStatusValue may obtain before an emergency shutdown of the managed device is initiated." ::= { ax2000rTemperatureStatusEntry 4 } ax2000rTemperatureState OBJECT-TYPE SYNTAX INTEGER { normal(1), caution(2), warning(3), fatal(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the testpoint being instrumented." ::= { ax2000rTemperatureStatusEntry 5 } ax2000rRpBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rRpBoardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing RP(Routing Processor) boards information about specific chassis." ::= { ax2000rRpBoard 1 } ax2000rRpBoardEntry OBJECT-TYPE SYNTAX Ax2000rRpBoardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing RP(Routing Processor) boards about specific chassis." INDEX { ax2000rChassisIndex,ax2000rRpBoardIndex } ::= { ax2000rRpBoardTable 1 } Ax2000rRpBoardTableEntry ::= SEQUENCE { ax2000rRpBoardIndex INTEGER, ax2000rRpBoardType INTEGER, ax2000rRpOperStatus INTEGER, ax2000rRpBoardName DisplayString, ax2000rRpBoardAbbreviation DisplayString, ax2000rRpBoardProductCode DisplayString, ax2000rRpMemoryTotalSize INTEGER, ax2000rRpMemoryUsedSize INTEGER, ax2000rRpMemoryFreeSize INTEGER, ax2000rRpOption1CardName DisplayString, ax2000rRpOption1CardAbbreviation DisplayString, ax2000rRpOption1CardProductCode INTEGER, ax2000rRpOption2CardName DisplayString, ax2000rRpOption2CardAbbreviation DisplayString, ax2000rRpOption2CardProductCode INTEGER, ax2000rRpCpuLoad1m INTEGER } ax2000rRpBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Position information of the RP slots. The value is from 1 to ax2000rRpBoardNumber." ::= { ax2000rRpBoardEntry 1 } ax2000rRpBoardType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RP(Routing Processor) boards ID. RP-A (8192) (0x2000) RP-A1 (8448) (0x2100) RP-C (9216) (0x2400) RP-D (9472) (0x2500) RP-C6 (9728) (0x2600) RP-D6 (9984) (0x2700) The value is -1 when RP board is disconnected." ::= { ax2000rRpBoardEntry 2 } ax2000rRpOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), initialization(3), down(4), closed(5), inactive(6), disconnect(32) } ACCESS read-only STATUS mandatory DESCRIPTION "Operation stasus of RP board.(STATUS LED)" ::= { ax2000rRpBoardEntry 3 } ax2000rRpBoardName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "RP board name. When RP board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 4 } ax2000rRpBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The abbreviation name of RP board. When RP board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 5 } ax2000rRpBoardProductCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The revision of RP board. When RP board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 6 } ax2000rRpMemoryTotalSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total memory sizes of RP. The value is displayed in kilobyte(KB). The value is -1 when RP board is disconnected." ::= { ax2000rRpBoardEntry 7 } ax2000rRpMemoryUsedSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Using memory sizes of RP. The value is displayed in kilobyte(KB). The value is -1 when RP board is disconnected." ::= { ax2000rRpBoardEntry 8 } ax2000rRpMemoryFreeSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Free memory sizes of RP. The value is displayed in kilobyte(KB). The value is -1 when RP board is disconnected." ::= { ax2000rRpBoardEntry 9 } ax2000rRpOption1CardName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Product name of RP board that is loaded onto slot of secret cord and compression option. When RP board is disconnected or option card isn't loaded, this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 10 } ax2000rRpOption1CardAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Product name of the board which is loaded into RP cryptogram/compress option slot.When RP board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 11 } ax2000rRpOption1CardProductCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Product code of the board which is loaded into RP cryptogram/compress option slot.When RP board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 12 } ax2000rRpOption2CardName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Product name of the board which is loaded into RP statistics option slot.When RP board is disconnected,this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 13 } ax2000rRpOption2CardAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Abbreviation name of the board which is loaded into RP statistics option slot.When RP board is disconnected,this will be an OCTET STRING of zero length." ::= { ax2000rRpBoardEntry 14 } ax2000rRpOption2CardProductCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Product management code of board which is loaded into RP statistics option slot.When RP board is disconnected,the value is -1." ::= { ax2000rRpBoardEntry 15 } ax2000rRpCpuLoad1m OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The average,over the last minute,of a percentage of time that this processor was utilized for processing and transferring data. The rate of use CPU is -1, except that RP status is active." ::= { ax2000rRpBoardEntry 16 } ax2000rNifBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rNifBoardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Network Interface cards (NIF) information that slot is loaded." ::= { ax2000rNifBoard 1 } ax2000rNifBoardEntry OBJECT-TYPE SYNTAX Ax2000rNifBoardTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing NIF information about specific chassis." INDEX { ax2000rChassisIndex,ax2000rNifBoardSlotIndex } ::= { ax2000rNifBoardTable 1 } Ax2000rNifBoardTableEntry ::= SEQUENCE { ax2000rNifBoardSlotIndex INTEGER, ax2000rNifBoardType INTEGER, ax2000rNifBoardOperStatus INTEGER, ax2000rNifBoardName DisplayString, ax2000rNifBoardAbbreviation DisplayString, ax2000rNifBoardProductCode INTEGER, ax2000rNifPhysLineNumber INTEGER, ax2000rNifSerialNumber DisplayString } ax2000rNifBoardSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Position information of NIF loading slot. The value is from 1 to ax2000rNifBoardNumber. modelBH : 1-2 model1B : 1,3 model2S model2B : 1-3 model4, model4S : 1-4 model6H : 1-6 model10,model10H : 1-10 model20,model20H : 1-20" ::= { ax2000rNifBoardEntry 1 } ax2000rNifBoardType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of connecting package.The value is register value of NIF package. other (1) 8-port 10BASE-T/100BASE-TX (16384) 4-port 10BASE-T/100BASE-TX (16385) 1-port 10BASE-T/100BASE-TX (17153) 1-port 1000BASE-LX (16387) 1-port 1000BASE-SX (16388) 1-port 1000BASE-LH (16389) 4-port 100BASE-FX (16390) 4-port 100BASE-FX(middle) (16391) 4-port 100BASE-FX(long) (16392) 8-port 10BASE-T/100BASE-TX (16393) 1-port 1000BASE-LX (16394) 1-port 1000BASE-SX (16395) 1-port 1000BASE-LH8 (16396) 1-port 1000BASE-LH (16645) 8-port 10BASE-T/100BASE-TX (16649) 1-port 1000BASE-LX (16650) 1-port 1000BASE-SX (16651) 1-port 1000BASE-LH8 (16652) 4-port 1000BASE-X (16897) 4-port serial(V.24/V.35/X.21) (32769) 8-port BRI(leasedline/dialup) (32772) 4-port PRI(leasedline/dialup) (32780) 2-port PRI(leasedline/dialup) (32778) 4-port T1(leasedline) (32784) 2-port PRI2-port BRI(leasedline/dialup) (32795) 2-port 6.3Minterface(leasedline) (32793) 1-port 6.3Minterface(leasedline) (32791) 4-port E1(leasedline) (32788) 8-port PRI(leasedline/dialup) (32790) 8-port E1(leased line) (32796) 1-port CT3(leased line) (32798) 1-port CE3(leasedline) (32799) 2-port E3(leasedline) (41032) 2-port OC-3c/STM-1POS(single-mode) (41090) 2-port OC-3c/STM-1POS(multi-mode) (41091) 2-port OC-3c/STM-1POS(single-modeMPLS) (41092) 2-port OC-3c/STM-1POS(multi-modeMPLS) (41093) 1-port OC-12c/STM-4POS(single-mode) (41104) 1-port OC-12c/STM-4POS(single-modeMPLS) (41108) 1-port OC-48c/STM-16POS(single-mode) (41120) 2-port T3(leasedline) (41024) 8-port OC-3c/STM-1POS(multi-mode) (41136) 8-port OC-3c/STM-1POS(single-mode) (41137) 4-port OC-12c/STM-4POS(multi-mode) (41152) 4-port OC-12c/STM-4POS(single-mode) (41153) 1-port OC-48c/STM-16POS(single-mode) (41168) 1-port OC-48c/STM-16POS(single-modenif-aps) (41169) 1-port OC-48c/STM-16POS(single-modemiddle) (41172) 1-port OC-48c/STM-16POS(single-modemiddlenif-aps) (41173) 1-port OC-48c/STM-16POS(single-modelong) (41174) 1-port OC-48c/STM-16POS(single-modelongnif-aps) (41175) 1-port OC-3c/STM-1ATM(multi-mode) (49152) 1-port OC-3c/STM-1ATM(single-mode) (49153) 1-port 25MATM (49155) 8-port OC-3c/STM-1ATM(multi-mode) (49168) 8-port OC-3c/STM-1ATM(single-mode) (49169) 8-port OC-3c/STM-1ATM(single-mode long) (49170) 2-port OC-12c/STM-4ATM(multi-mode) (49184) 2-port OC-12c/STM-4ATM(single-mode) (49185) 2-port OC-12c/STM-4ATM(single-mode long) (49186) The value is -1 when RP is disconnected or NIF disconnected." ::= { ax2000rNifBoardEntry 2 } ax2000rNifBoardOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), initialization(3), down(4), closed(5), lock(6), disconnect(32) } ACCESS read-only STATUS mandatory DESCRIPTION "Operation status of Network InterFace(NIF) board.(STATUS LED)" ::= { ax2000rNifBoardEntry 3 } ax2000rNifBoardName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Network InterFace(NIF) board name. When RP board or NIF board is disconnected,this will be an OCTET STRING of zero length." ::= { ax2000rNifBoardEntry 4 } ax2000rNifBoardAbbreviation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "The abbreviation name of Network InterFace(NIF) board. When RP board or NIF board is disconnected, this will be an OCTET STRING of zero length." ::= { ax2000rNifBoardEntry 5 } ax2000rNifBoardProductCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The product management code of Network InterFace(NIF) board.The value is -1 when RP board or NIF board is disconncted." ::= { ax2000rNifBoardEntry 6 } ax2000rNifPhysLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Network InterFace(NIF)'s physical port.The max is 8. The value is -1 when value of ax2000rNifCardType is -1 or other(1)." ::= { ax2000rNifBoardEntry 7 } ax2000rNifSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Management information (SerialNumber) of Network InterFace(NIF) package." ::= { ax2000rNifBoardEntry 8 } ax2000rPhysLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rPhysLineTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing physical port information." ::= { ax2000rPhysLine 1 } ax2000rPhysLineEntry OBJECT-TYPE SYNTAX Ax2000rPhysLineTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing physical port." INDEX { ax2000rChassisIndex, ax2000rNifBoardSlotIndex, ax2000rPhysLineIndex } ::= { ax2000rPhysLineTable 1 } Ax2000rPhysLineTableEntry ::= SEQUENCE { ax2000rPhysLineIndex INTEGER, ax2000rPhysLineConnectorType INTEGER, ax2000rPhysLineOperStatus INTEGER, ax2000rPhysLineIfIndexNumber INTEGER } ax2000rPhysLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Physical port number. The value is from 1 to ax2000rNifLineNumber." ::= { ax2000rPhysLineEntry 1 } ax2000rPhysLineConnectorType OBJECT-TYPE SYNTAX INTEGER { other(1), v24(2), v35(5), x21(6), type1000BASE-LX(301), type1000BASE-SX(302) } ACCESS read-only STATUS mandatory DESCRIPTION "Connector type is connected physical port. The value is 1(other) when connector is disconnected or connector type is unknown.When displaying in pannel, requests board name of NIF,then will display it. The value is -1 when RP or NIF board is disconnected." ::= { ax2000rPhysLineEntry 2 } ax2000rPhysLineOperStatus OBJECT-TYPE SYNTAX INTEGER { other(1), active(2), initialization(3), down(4), lock(6), close(7), line-fault(8), test(9), nothing-configuration(10), missing-configuration(11), remote-loop-back-test-mode(12) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of physical port. The value is -1 when RP or NIF board is disconnected." ::= { ax2000rPhysLineEntry 3 } ax2000rPhysLineIfIndexNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of ifIndex which is included in physical port.The value is -1 when RP board or NIF board is disconnected." ::= { ax2000rPhysLineEntry 4 } -- ax2000rLineIfTable OBJECT-TYPE SYNTAX SEQUENCE OF Ax2000rLineIfTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing physical port correspond to ifIndex." ::= { ax2000rInterface 1 } ax2000rLineIfEntry OBJECT-TYPE SYNTAX Ax2000rLineIfTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing ifIndex is assigned to physical port." INDEX { ax2000rChassisIndex, ax2000rNifBoardSlotIndex, ax2000rPhysLineIndex, ax2000rLineIfIndex } ::= { ax2000rLineIfTable 1 } Ax2000rLineIfTableEntry ::= SEQUENCE { ax2000rLineIfIndex INTEGER, ax2000rIfIndex INTEGER, ax2000rIfIpAddress IpAddress, ax2000rIfIpv6Address OCTET STRING } ax2000rLineIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The value of ifIndex to distinguish entry of this table.The value is from 1 to ax2000rPhysLineIfIndexNumber." ::= { ax2000rLineIfEntry 1 } ax2000rIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of ifIndex which is assigned to this physical port. The value is 0 when ifIndex is not assigned to this physical port." ::= { ax2000rLineIfEntry 2 } ax2000rIfIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address correspond to ifIndex which is assigned to this physical port. If IP address is not assigned, it is '0.0.0.0'." ::= { ax2000rLineIfEntry 3 } ax2000rIfIpv6Address OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The IPv6 address correspond to ifIndex which is assigned to this physical port. If IPv6 address is not assigned, it is '00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00'." ::= { ax2000rLineIfEntry 4 } -- Traps for use by AlaxalA networks AX2000R -- Traps are defined using the conventions in RFC 1215. ax2000rSystemMsgTrap TRAP-TYPE ENTERPRISE ax2000r VARIABLES { ax2000rSystemMsgType, ax2000rSystemMsgTimeStamp, ax2000rSystemMsgLevel, ax2000rSystemMsgEventPoint, ax2000rSystemMsgEventInterfaceID, ax2000rSystemMsgEventCode, ax2000rSystemMsgAdditionalCode, ax2000rSystemMsgText } DESCRIPTION "System message is displayed." ::= 1 ax2000rStandbySystemUpTrap TRAP-TYPE ENTERPRISE ax2000r VARIABLES { ax2000rChassisIndex, ax2000rRmBoardIndex } DESCRIPTION "Standby system is restarted." ::= 2 ax2000rStandbySystemDownTrap TRAP-TYPE ENTERPRISE ax2000r VARIABLES { ax2000rChassisIndex, ax2000rRmBoardIndex } DESCRIPTION "Standby system is failed." ::= 3 ax2000rTemperatureTrap TRAP-TYPE ENTERPRISE ax2000r VARIABLES { ax2000rChassisIndex, ax2000rRmBoardIndex, ax2000rTemperatureStatusIndex, ax2000rTemperatureStatusDescr, ax2000rTemperatureStatusValue, ax2000rTemperatureState } DESCRIPTION "A ax2000rTemperatureTrap is sent if the temperature measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage)." ::= 4 -- ATM PVC Traps ax2000rAtmPVcTrap TRAP-TYPE ENTERPRISE ax2000r VARIABLES { ifIndex, axrAtmIntfPVcFailures, axrAtmIntfCurrentlyFailingPVcls} DESCRIPTION "A notification indicating that one or more PVPLs or PVCLs on this interface has failed since the last axrAtmPVcFailuresTrap was sent. If this trap has not been sent for the last axrAtmIntfPVcNotificationInterval, then it will be sent on the next increment of axrAtmIntfPVcFailures." ::= 5 END