-- ======================================================================= -- File : FIBROLAN-MIB-SFP.mib -- Description : Private MIB file for FibroLAN SFP device -- By : Tal Katz-Touaf, Shamir Stein-Ackerman -- MIB Version : 1.1 -- MetroStar Version : 1.6.2/build 12 -- Date : March 27, 2008 -- ======================================================================= -- -- -- Copyright Fibrolan, 2008. All rights reserved. -- -- Reproduction of this document is authorized on condition that this -- copyright notice is included. -- FIBROLAN-MIB-SFP DEFINITIONS ::= BEGIN IMPORTS enterprises, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC --FROM RFC1213-MIB MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF flMsChassisMvIndex, flMsChassisModuleMvIndex FROM FIBROLAN-MIB-METRO-STAR-MV flMsModuleMvChannelIndex FROM FIBROLAN-MIB-MSMODULE; flSfp MODULE-IDENTITY LAST-UPDATED "0803270000Z" ORGANIZATION "FibroLAN ltd" CONTACT-INFO "http://www.fibrolan.com" DESCRIPTION "The MIB module to describe FibroLAN SFP device. Copyright (C) Fibrolan Ltd (2008)." ::= { enterprises 4467 100 500 100 } -- conformance information flSfpMIBConformance OBJECT IDENTIFIER ::= { flSfp 1 } flSfpMIBCompliances OBJECT IDENTIFIER ::= { flSfpMIBConformance 1 } flSfpMIBGroups OBJECT IDENTIFIER ::= { flSfpMIBConformance 2 } -- compliance statements flSfpMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for flSfp entities" MODULE FIBROLAN-MIB-METRO-STAR-MV MANDATORY-GROUPS{ flMsChassisGroup, flMsChassisModulesGroup } MODULE FIBROLAN-MIB-MSMODULE MANDATORY-GROUPS{ flMsModuleMvChannelsGroup } MODULE -- this module MANDATORY-GROUPS { flSfpDeviceGroup, flSfpPortsGroup, flSfpMonitoringGroup } ::= { flSfpMIBCompliances 1 } flSfpDeviceGroup OBJECT-GROUP OBJECTS { flSfpDevicePortIndex, flSfpDeviceLocalRemoteIndex, flSfpDeviceRemoteChannelIndex, flSfpDeviceRemotePortIndex, flSfpDeviceSerialNumber, flSfpDevicePartNumber, flSfpDevicePortName, flSfpDeviceType, flSfpDeviceRange, flSfpDeviceTxWl, flSfpDeviceRxwl, flSfpDeviceState } STATUS current DESCRIPTION "SFP standard status objects." ::= { flSfpMIBGroups 1 } flSfpPortsGroup OBJECT-GROUP OBJECTS { flSfpDevicePortIndex, flSfpDeviceLocalRemoteIndex, flSfpDeviceRemoteChannelIndex, flSfpDeviceRemotePortIndex, flSfpPortSignalDetect, flSfpPortLink, flSfpPortEnable } STATUS current DESCRIPTION "SFP port status and configuration objects" ::= { flSfpMIBGroups 2 } flSfpMonitoringGroup OBJECT-GROUP OBJECTS { flSfpDevicePortIndex, flSfpDeviceLocalRemoteIndex, flSfpDeviceRemoteChannelIndex, flSfpDeviceRemotePortIndex, flSfpDeviceMonitoringRxPower, flSfpDeviceMonitoringTxPower, flSfpDeviceMonitoringTemperature, flSfpDeviceMonitoringTxBias, flSfpDeviceMonitoringSupplyVoltage } STATUS current DESCRIPTION "SFP monitoring (digital diagnostics) group." ::= { flSfpMIBGroups 3 } -- ************************************************************ -- ************************************************************ -- FibroLan Object Identifier Definition -- ************************************************************ -- ************************************************************ fibrolan OBJECT IDENTIFIER ::= { enterprises 4467 } fibrolanSNMP OBJECT IDENTIFIER ::= { fibrolan 100 } flMetroStarMv OBJECT IDENTIFIER ::= { fibrolanSNMP 500 } --flSfp OBJECT IDENTIFIER ::= { flMetroStarMv 100 } flSfpDevice OBJECT IDENTIFIER ::= { flSfp 10 } -- ************************************************************ -- Device table -- ************************************************************ flSfpDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF FlSfpDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for managing device level parameters" ::= { flSfpDevice 1 } flSfpDeviceEntry OBJECT-TYPE SYNTAX FlSfpDeviceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of the table." INDEX { flMsChassisMvIndex, flMsChassisModuleMvIndex, flMsModuleMvChannelIndex, flSfpDevicePortIndex, flSfpDeviceLocalRemoteIndex, flSfpDeviceRemoteChannelIndex, flSfpDeviceRemotePortIndex } ::= { flSfpDeviceTable 1 } FlSfpDeviceEntry ::= SEQUENCE { flSfpDevicePortIndex INTEGER, flSfpDeviceLocalRemoteIndex INTEGER, flSfpDeviceRemoteChannelIndex INTEGER, flSfpDeviceRemotePortIndex INTEGER, flSfpDeviceSerialNumber DisplayString, flSfpDevicePartNumber DisplayString, flSfpDevicePortName DisplayString, flSfpDeviceType DisplayString, flSfpDeviceRange INTEGER, flSfpDeviceTxWl INTEGER, flSfpDeviceRxwl INTEGER, flSfpDeviceState INTEGER } flSfpDevicePortIndex OBJECT-TYPE SYNTAX INTEGER(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Sfp port index" ::= { flSfpDeviceEntry 1 } flSfpDeviceLocalRemoteIndex OBJECT-TYPE SYNTAX INTEGER { local (1), remote (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Remote/Local device indicator" ::= { flSfpDeviceEntry 2 } flSfpDeviceRemoteChannelIndex OBJECT-TYPE SYNTAX INTEGER(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Sfp remote channel index" ::= { flSfpDeviceEntry 3 } flSfpDeviceRemotePortIndex OBJECT-TYPE SYNTAX INTEGER(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Sfp remote port index" ::= { flSfpDeviceEntry 4 } flSfpDeviceSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device's serial number" ::= { flSfpDeviceEntry 5 } flSfpDevicePartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device's part number" ::= { flSfpDeviceEntry 6 } flSfpDevicePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device's port name" ::= { flSfpDeviceEntry 7 } flSfpDeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device's type" ::= { flSfpDeviceEntry 8 } flSfpDeviceRange OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Device's range in meters" ::= { flSfpDeviceEntry 9 } flSfpDeviceTxWl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Device's Tx wave-length in nano-meters" ::= { flSfpDeviceEntry 10 } flSfpDeviceRxwl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Device's Rx wave-length in nano-meters" ::= { flSfpDeviceEntry 11 } flSfpDeviceState OBJECT-TYPE SYNTAX INTEGER { unplugged (1), invalid (2), authenticated (3), unknown (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Device's state" ::= { flSfpDeviceEntry 12 } -- ************************************************************ -- Ports table -- ************************************************************ flSfpPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF FlSfpPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for managing ports level parameters" ::= { flSfpDevice 2 } flSfpPortsEntry OBJECT-TYPE SYNTAX FlSfpPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of the table." INDEX { flMsChassisMvIndex, flMsChassisModuleMvIndex, flMsModuleMvChannelIndex, flSfpDevicePortIndex, flSfpDeviceLocalRemoteIndex, flSfpDeviceRemoteChannelIndex, flSfpDeviceRemotePortIndex } ::= { flSfpPortsTable 1 } FlSfpPortsEntry ::= SEQUENCE { flSfpPortSignalDetect INTEGER, flSfpPortLink INTEGER, flSfpPortEnable INTEGER } flSfpPortSignalDetect OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port's Signal Detect status" ::= { flSfpPortsEntry 5 } flSfpPortLink OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), kld (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port's Link status" ::= { flSfpPortsEntry 6 } flSfpPortEnable OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), n-a (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port's Enable mode" ::= { flSfpPortsEntry 7 } -- ************************************************************ -- Monitoring table -- ************************************************************ flSfpDeviceMonitoringTable OBJECT-TYPE SYNTAX SEQUENCE OF FlSfpDeviceMonitoringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for SFP monitoring (digital diagnostics) data" ::= { flSfpDevice 3 } flSfpDeviceMonitoringEntry OBJECT-TYPE SYNTAX FlSfpDeviceMonitoringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries of the table." INDEX { flMsChassisMvIndex, flMsChassisModuleMvIndex, flMsModuleMvChannelIndex, flSfpDevicePortIndex, flSfpDeviceLocalRemoteIndex, flSfpDeviceRemoteChannelIndex, flSfpDeviceRemotePortIndex } ::= { flSfpDeviceMonitoringTable 1 } FlSfpDeviceMonitoringEntry ::= SEQUENCE { flSfpDeviceMonitoringRxPower INTEGER, flSfpDeviceMonitoringTxPower INTEGER, flSfpDeviceMonitoringTemperature INTEGER, flSfpDeviceMonitoringTxBias INTEGER, flSfpDeviceMonitoringSupplyVoltage INTEGER } flSfpDeviceMonitoringRxPower OBJECT-TYPE SYNTAX INTEGER UNITS "0.01dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Received average optical power in [0.01dBm]" ::= { flSfpDeviceMonitoringEntry 1 } flSfpDeviceMonitoringTxPower OBJECT-TYPE SYNTAX INTEGER UNITS "0.01dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitted average optical power in [0.01dBm]" ::= { flSfpDeviceMonitoringEntry 2 } flSfpDeviceMonitoringTemperature OBJECT-TYPE SYNTAX INTEGER UNITS "0.1 degrees Celsius (oC)" MAX-ACCESS read-only STATUS current DESCRIPTION "Device temperature in [0.1oC]" ::= { flSfpDeviceMonitoringEntry 3 } flSfpDeviceMonitoringTxBias OBJECT-TYPE SYNTAX INTEGER UNITS "micro Ampere (uA)" MAX-ACCESS read-only STATUS current DESCRIPTION "Transmitter bias current in [uA]" ::= { flSfpDeviceMonitoringEntry 4 } flSfpDeviceMonitoringSupplyVoltage OBJECT-TYPE SYNTAX INTEGER UNITS "100 micro Volt (100uV)" MAX-ACCESS read-only STATUS current DESCRIPTION "Internal supply voltage in [100uV]" ::= { flSfpDeviceMonitoringEntry 5 } END