-- OPTIX-RTN-ODU-MGR-MIB -- MIB generated by ExcelToMIB tool 1.0 -- -- ================================================================= -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved -- Description: -- Reference: -- Version: V1.00 -- History: -- ,, -- ================================================================= -- OPTIX-RTN-ODU-MGR-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-GROUP,MODULE-COMPLIANCE FROM SNMPv2-CONF Unsigned32,Integer32,OBJECT-TYPE,MODULE-IDENTITY,NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC optixProvisionRtn FROM OPTIX-OID-MIB ; optixRtnOduMgr MODULE-IDENTITY LAST-UPDATED "201204160935Z" ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO "R&D Building Huawei Technologies Co., Ltd. Bantian, Longgang District Shenzhen, P. R. China http://www.huawei.com Zip:518129 E-mail:support@huawei.com" DESCRIPTION "This module is used to configure and query RF unit parameters for a radio link, including the RF unit frequency, power, and working status." REVISION "201204160935Z" DESCRIPTION "The initial revision of this MIB module1." ::={ optixProvisionRtn 4 } OPTIXRtnCombineMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the combine mode of a RFU-SD board." SYNTAX INTEGER { main(0), slave(1), combine(2) } OPTIXRtnFiberEqualState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates RFU-SD fiber equal state." SYNTAX INTEGER { start(1) } OPTIXRtnOduWorkStateType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Indicates the working status of RF unit. Values: 0: muted 1: unmuted" SYNTAX INTEGER { mute(0), unmute(1) } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10 optixODU OBJECT IDENTIFIER ::= { optixRtnOduMgr 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.10 optixRtnOduIndexTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serves as the public index table for attribute tables related to an RF unit." ::= { optixODU 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.10.1 optixRtnOduIndexEntry OBJECT-TYPE SYNTAX OptixRtnOduIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the index entry for an RF unit." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduIndexTable 1 } OptixRtnOduIndexEntry ::= SEQUENCE { optixRtnOduIndex1 Unsigned32, optixRtnOduIndex2 Unsigned32, optixRtnOduIndex3 Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.10.1.1 optixRtnOduIndex1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the RF unit board ID." ::= { optixRtnOduIndexEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.10.1.2 optixRtnOduIndex2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subboard ID." ::= { optixRtnOduIndexEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.10.1.3 optixRtnOduIndex3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Port ID." ::= { optixRtnOduIndexEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.11 optixRtnOduGeneralAttrTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduGeneralAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the table of general attributes of an ODU." ::= { optixODU 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.11.1 optixRtnOduGeneralAttrEntry OBJECT-TYPE SYNTAX OptixRtnOduGeneralAttrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates an entry of general attributes of an ODU." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnOduGeneralAttrTable 1 } OptixRtnOduGeneralAttrEntry ::= SEQUENCE { optixRtnOduFademarginAlmTh Unsigned32, optixRtnOduCurrentFilter Unsigned32, optixRtnOduAllFilterListInfo OCTET STRING, optixRtnOduLoopMode INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.11.1.1 optixRtnOduFademarginAlmTh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the alarming threshold in the unit of 0.1 dB." ::= { optixRtnOduGeneralAttrEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.11.1.2 optixRtnOduCurrentFilter OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the filter, expressed in KHz." ::= { optixRtnOduGeneralAttrEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.11.1.3 optixRtnOduAllFilterListInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the supported filter list. Every 4 bytes represent a filter, expressed in KHz." ::= { optixRtnOduGeneralAttrEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.11.1.4 optixRtnOduLoopMode OBJECT-TYPE SYNTAX INTEGER { noloop(0), inloop(1), outloop(2), masterinloop(3), slaveinloop(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the loop mode: 0:no loop 1:in loop 2:out loop" ::= { optixRtnOduGeneralAttrEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.13 optixRtnOduFactoryInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduFactoryInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Query ODU manufacturers information." ::= { optixODU 13 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.13.1 optixRtnOduFactoryInfoEntry OBJECT-TYPE SYNTAX OptixRtnOduFactoryInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Query ODU manufacturers information." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduFactoryInfoTable 1 } OptixRtnOduFactoryInfoEntry ::= SEQUENCE { optixRtnOduFactoryInfo OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.13.1.1 optixRtnOduFactoryInfo OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the information of ODU manufacturers." ::= { optixRtnOduFactoryInfoEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.16 optixRtnOduPowerSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduPowerSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the RF unit transmit and receive frequencies." ::= { optixODU 16 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.16.1 optixRtnOduPowerSwitchEntry OBJECT-TYPE SYNTAX OptixRtnOduPowerSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for power switch." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnOduPowerSwitchTable 1 } OptixRtnOduPowerSwitchEntry ::= SEQUENCE{ optixOduPowerSwitch INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.16.1.1 optixOduPowerSwitch OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmit power switch" ::= { optixRtnOduPowerSwitchEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20 optixRtnOduFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the RF unit transmit and receive frequencies." ::= { optixODU 20 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1 optixRtnOduFrequencyEntry OBJECT-TYPE SYNTAX OptixRtnOduFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the RF unit transmit and receive frequencies." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduFrequencyTable 1 } OptixRtnOduFrequencyEntry ::= SEQUENCE { optixRtnOduCfgTxFreq Unsigned32, optixRtnOduCfgTRSpacing Unsigned32, optixRtnOduActualTxFreq Unsigned32, optixRtnOduActualRxFreq Unsigned32, optixRtnOduMinTxFreq Unsigned32, optixRtnOduMaxTxFreq Unsigned32, optixRtnOduRealRTRSpacing Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.1 optixRtnOduCfgTxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmit frequency of an RF unit. When frequencies of the transmitter/receiver at both ends match, signals can be transmitted and received successfully. Unit: kHz" ::= { optixRtnOduFrequencyEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.2 optixRtnOduCfgTRSpacing OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the TR spacing of an RF unit board to avoid interference. Unit: kHz" ::= { optixRtnOduFrequencyEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.3 optixRtnOduActualTxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual transmit frequency of an RF unit. Unit: kHz" ::= { optixRtnOduFrequencyEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.4 optixRtnOduActualRxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual receive frequency of an RF unit. Unit: kHz" ::= { optixRtnOduFrequencyEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.5 optixRtnOduMinTxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum range of an RF unit frequency point. Unit: kHz" ::= { optixRtnOduFrequencyEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.6 optixRtnOduMaxTxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum range of an RF unit frequency point. Unit: kHz" ::= { optixRtnOduFrequencyEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.20.1.7 optixRtnOduRealRTRSpacing OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the real TR spacing of an RF unit. Unit: kHz" ::= { optixRtnOduFrequencyEntry 7 } --1,3,6,1,4,1,2011,2,25,4,40,4,10,23 optixRtnOduAmTxpowerTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduAmTxpowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters of the txpower range." ::= { optixODU 23 } --1,3,6,1,4,1,2011,2,25,4,40,4,10,23.1 optixRtnOduAmTxpowerEntry OBJECT-TYPE SYNTAX OptixRtnOduAmTxpowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the txpower range." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnOduAmTxpowerTable 1 } OptixRtnOduAmTxpowerEntry ::= SEQUENCE { optixRtnOduAcm OCTET STRING } --1,3,6,1,4,1,2011,2,25,4,40,4,10,23.1.1 optixRtnOduAcm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "this leaf sis AM modle." ::={optixRtnOduAmTxpowerEntry 1} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30 optixRtnOduPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters of the RF unit transmit and receive power." ::= { optixODU 30 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1 optixRtnOduPowerEntry OBJECT-TYPE SYNTAX OptixRtnOduPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the RF unit transmit and receive powers." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduPowerTable 1 } OptixRtnOduPowerEntry ::= SEQUENCE { optixRtnOduCfgTxPower Integer32, optixRtnOduCfgToBeRxPower Integer32, optixRtnOduTxPowerHighTh Integer32, optixRtnOduTxPowerLowTH Integer32, optixRtnOduRxPowerHighTh Integer32, optixRtnOduRxPowerLowTH Integer32, optixRtnOduCfgMaxTxpower Integer32, optixRtnOduActualTxPower Integer32, optixRtnOduActualRxPower Integer32, optixRtnOduMaxTxpower Integer32, optixRtnOduMinTxpower Integer32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.1 optixRtnOduCfgTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmit power of an RF port. Signed type Value range: -100 to +350 Unit: 0.1 dBm" DEFVAL{ 100 } ::= { optixRtnOduPowerEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.2 optixRtnOduCfgToBeRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the power expected to receive by an RF port. Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.3 optixRtnOduTxPowerHighTh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the upper threshold of the transmit power. Signed type The value range: -100 to +350 Unit: 0.1 dBm" DEFVAL{ 350 } ::= { optixRtnOduPowerEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.4 optixRtnOduTxPowerLowTH OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lower threshold of the transmit power. Signed type The value range: -100 to +350 Unit: 0.1 dBm" DEFVAL{ 350 } ::= { optixRtnOduPowerEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.5 optixRtnOduRxPowerHighTh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the upper threshold of the receive power. Signed type Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.6 optixRtnOduRxPowerLowTH OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lower threshold of the receive power. Signed type Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.7 optixRtnOduCfgMaxTxpower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the maximum transmit power of an RF unit board. When the ACM function is disabled, the maximum transmit power in the current mode is returned. When the ACM function is enabled, the maximum transmit power in the guaranteed capacity modulation mode is returned." ::= { optixRtnOduPowerEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.8 optixRtnOduActualTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual transmit power of an RF port. Signed type Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.9 optixRtnOduActualRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual receive power of an RF port. Signed type Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.10 optixRtnOduMaxTxpower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum value of the actual transmit power. Signed type Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.30.1.11 optixRtnOduMinTxpower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum value of the actual transmit power. Signed type Unit: 0.1 dBm" ::= { optixRtnOduPowerEntry 11 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.40 optixRtnOduWorkStateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduWorkStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the current emission status of an RF unit board." ::= { optixODU 40 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.40.1 optixRtnOduWorkStateEntry OBJECT-TYPE SYNTAX OptixRtnOduWorkStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the transmission status entry for an RF unit." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduWorkStateTable 1 } OptixRtnOduWorkStateEntry ::= SEQUENCE { optixRtnOduConfigWorkState OPTIXRtnOduWorkStateType, optixRtnOduActualWorkState INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.40.1.1 optixRtnOduConfigWorkState OBJECT-TYPE SYNTAX OPTIXRtnOduWorkStateType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the transmission status of an RF transmitter. Values: 0: muted 1: unmuted" DEFVAL{ 1 } ::= { optixRtnOduWorkStateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.40.1.2 optixRtnOduActualWorkState OBJECT-TYPE SYNTAX INTEGER { mute(0), unmute(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the transmission actual status of an RF transmitter. Values: 0: muted 1: unmuted" ::= { optixRtnOduWorkStateEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43 optixRtnRegOduLHFreqScanTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnRegOduLHFreqScanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the information about RF unit, frequency scanning , and obtaining of interfering frequency." ::= { optixODU 43 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1 optixRtnRegOduLHFreqScanEntry OBJECT-TYPE SYNTAX OptixRtnRegOduLHFreqScanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for RF unit frequency scanning." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3} ::= { optixRtnRegOduLHFreqScanTable 1 } OptixRtnRegOduLHFreqScanEntry ::= SEQUENCE { optixRtnOduLHScanFreqInterference INTEGER, optixRtnOduLHScanFreqLeakage INTEGER, optixRtnOduLHScanFreqIntermodulation INTEGER, optixRtnOduLHScanFreqStaFreq INTEGER, optixRtnOduLHScanFreqEndFreq INTEGER, optixRtnOduLHScanFreqStep INTEGER, optixRtnOduLHScanFreqBandWidth INTEGER, optixRtnOduLHScanFreqNumber INTEGER, optixRtnOduLHScanFreqBids OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.4 optixRtnOduLHScanFreqInterference OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), unknown(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the information of Interference." ::= { optixRtnRegOduLHFreqScanEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.5 optixRtnOduLHScanFreqLeakage OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), unknown(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the information of Leakage." ::= { optixRtnRegOduLHFreqScanEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.6 optixRtnOduLHScanFreqIntermodulation OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1), unknown(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the information of Intermodulation." ::= { optixRtnRegOduLHFreqScanEntry 6} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.7 optixRtnOduLHScanFreqStaFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the frequence of starting scanning ." ::= { optixRtnRegOduLHFreqScanEntry 7} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.8 optixRtnOduLHScanFreqEndFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the frequence of ending scanning." ::= { optixRtnRegOduLHFreqScanEntry 8} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.9 optixRtnOduLHScanFreqStep OBJECT-TYPE SYNTAX INTEGER { step1p5m(10), step1p75m(11), step3p5m(12), step7m(13), step14m(14) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the step of scanning frequence." ::= { optixRtnRegOduLHFreqScanEntry 9} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.10 optixRtnOduLHScanFreqBandWidth OBJECT-TYPE SYNTAX INTEGER { bw3P5M(1), bw7M(2), bw14M(3), bw28M(4), bw40M(5), bw56M(6), bwFCC30M(7), bwFCC40M(8), bwFCC50M(9), bw250M(10), bw500M(11), bw750M(12), bw62P5M(16), bw125M(17), bw112M(23), bwFCC10M(24), bwFCC20M(25), bwFCC60M(28) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the bandwidth of scanning frequence." ::= { optixRtnRegOduLHFreqScanEntry 10} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.11 optixRtnOduLHScanFreqNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the number of scanning frequence." ::= { optixRtnRegOduLHFreqScanEntry 11} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.43.1.12 optixRtnOduLHScanFreqBids OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the board IDs of scanning frequence. format:number,bid1,bid2,...," ::= { optixRtnRegOduLHFreqScanEntry 12} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.44 optixRtnRegOduLHFreqScanResultTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnRegOduLHFreqScanResulEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the information about RF unit, frequency scanning , and obtaining of interfering frequency." ::= { optixODU 44 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.44.1 optixRtnRegOduLHFreqScanResulEntry OBJECT-TYPE SYNTAX OptixRtnRegOduLHFreqScanResulEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for RF unit frequency scanning." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3,optixRtnOduIndex4} ::= { optixRtnRegOduLHFreqScanResultTable 1 } OptixRtnRegOduLHFreqScanResulEntry ::= SEQUENCE { optixRtnOduLHScanResultRxFreq INTEGER, optixRtnOduLHScanResultMainRsl INTEGER, optixRtnOduLHScanResultSlaveRsl INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.44.1.5 optixRtnOduLHScanResultRxFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Rx frequency of frequency scanning." ::= { optixRtnRegOduLHFreqScanResulEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.44.1.6 optixRtnOduLHScanResultMainRsl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the main Rsl of frequency scanning." ::= { optixRtnRegOduLHFreqScanResulEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.44.1.7 optixRtnOduLHScanResultSlaveRsl OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the slave Rsl of frequency scanning." ::= { optixRtnRegOduLHFreqScanResulEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50 optixRtnOduFreqScanTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduFreqScanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes the information about RF unit start, frequency scanning stop, and obtaining of interfering frequency." ::= { optixODU 50 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1 optixRtnOduFreqScanEntry OBJECT-TYPE SYNTAX OptixRtnOduFreqScanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for RF unit frequency scanning." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduFreqScanTable 1 } OptixRtnOduFreqScanEntry ::= SEQUENCE { optixRtnOduStartScanStartFreq Unsigned32, optixRtnOduStartScanEndFreq Unsigned32, optixRtnOduStartScanStep INTEGER, optixRtnOduStartScanBWid INTEGER, optixRtnOduStopFreqScan INTEGER, optixRtnOduInterferenceFreqBwid INTEGER, optixRtnOduInterferenceFreqLeftChannel INTEGER, optixRtnOduInterferenceFreqCfgChannel INTEGER, optixRtnOduInterferenceFreqRightChannel INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.1 optixRtnOduStartScanStartFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the start frequency of frequency scanning. Unit:KHz" ::= { optixRtnOduFreqScanEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.2 optixRtnOduStartScanEndFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the end freqency of frequency scanning. Unit:KHz" ::= { optixRtnOduFreqScanEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.3 optixRtnOduStartScanStep OBJECT-TYPE SYNTAX INTEGER { step15M(1), step31M(2), step62M(3), step1P5M(10), step1P75M(11), step3P5M(12), step7M(13), step14M(14) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the step of frequency scanning. Values for RTN300:1-15M,2-31M,3- 62M. Values for RTN900:11-1P5M,12-1P75M,13-3P5M,14-7M,15-14M" ::= { optixRtnOduFreqScanEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.4 optixRtnOduStartScanBWid OBJECT-TYPE SYNTAX INTEGER { bw3P5M(1), bw7M(2), bw14M(3), bw28M(4), bw40M(5), bw56M(6), bwFCC30M(7), bwFCC40M(8), bwFCC50M(9), bw112M(23), bwFCC10M(24), bwFCC20M(25), bsFCC60M(28) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the bandwidth of frequency scanning,for calculating available frequencies." ::= { optixRtnOduFreqScanEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.5 optixRtnOduStopFreqScan OBJECT-TYPE SYNTAX INTEGER { stop(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the stop of frequency scanning." DEFVAL{ stop } ::= { optixRtnOduFreqScanEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.6 optixRtnOduInterferenceFreqBwid OBJECT-TYPE SYNTAX INTEGER { bw3P5M(1), bw7M(2), bw14M(3), bw28M(4), bw40M(5), bw56M(6), bwFCC30M(7), bwFCC40M(8), bwFCC50M(9), bw112M(23), bwFCC10M(24), bwFCC20M(25), bwFCC60M(28) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the configuration bandwidth." ::= { optixRtnOduFreqScanEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.7 optixRtnOduInterferenceFreqLeftChannel OBJECT-TYPE SYNTAX INTEGER { stateUnknown(-1), stateNoInterference(0), stateInterference(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the left channel state of configuration frequency" ::= { optixRtnOduFreqScanEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.8 optixRtnOduInterferenceFreqCfgChannel OBJECT-TYPE SYNTAX INTEGER { stateUnknown(-1), stateNoInterference(0), stateInterference(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current channel state of configuration frequency." ::= { optixRtnOduFreqScanEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.50.1.9 optixRtnOduInterferenceFreqRightChannel OBJECT-TYPE SYNTAX INTEGER { stateUnknown(-1), stateNoInterference(0), stateInterference(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the right channel state of configuration frequency." ::= { optixRtnOduFreqScanEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.60 optixRtnOduFreqScanAvailFreqTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduFreqScanAvailFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes Available frequencies of the RF unit frequency scanning." ::= { optixODU 60 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.60.1 optixRtnOduFreqScanAvailFreqEntry OBJECT-TYPE SYNTAX OptixRtnOduFreqScanAvailFreqEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the RF unit frequency scanning." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduAvailFreqList } ::= { optixRtnOduFreqScanAvailFreqTable 1 } OptixRtnOduFreqScanAvailFreqEntry ::= SEQUENCE { optixRtnOduAvailFreqList Unsigned32, optixRtnOduGetAvailableBwid INTEGER, optixRtnOduGetAvailableTxfreqs Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.60.1.1 optixRtnOduAvailFreqList OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the list number of available frequencies." ::= { optixRtnOduFreqScanAvailFreqEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.60.1.2 optixRtnOduGetAvailableBwid OBJECT-TYPE SYNTAX INTEGER { bw62P5M(16), bw125M(17), bw250M(10), bw500M(11), bw750M(12), bw3P5M(1), bw7M(2), bw14M(3), bw28M(4), bw40M(5), bw56M(6), bwFCC30M(7), bwFCC40M(8), bwFCC50M(9), bw112M(23), bwFCC10M(24), bwFCC20M(25), bwFCC60M(28) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bandwidth that inputted when starting the frequency scanning." ::= { optixRtnOduFreqScanAvailFreqEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.60.1.3 optixRtnOduGetAvailableTxfreqs OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the available freqencies of frequency scanning. Unit:KHz" ::= { optixRtnOduFreqScanAvailFreqEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.70 optixRtnOduFreqScanResultTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduFreqScanResultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes result of the RF unit frequency scanning" ::= { optixODU 70 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.70.1 optixRtnOduFreqScanResultEntry OBJECT-TYPE SYNTAX OptixRtnOduFreqScanResultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the RF unit frequency scanning." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduScanResultList } ::= { optixRtnOduFreqScanResultTable 1 } OptixRtnOduFreqScanResultEntry ::= SEQUENCE { optixRtnOduScanResultList Unsigned32, optixRtnOduScanResultRxFreq Unsigned32, optixRtnOduScanResultRxRsl Integer32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.70.1.1 optixRtnOduScanResultList OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the list of RF scanning results." ::= { optixRtnOduFreqScanResultEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.70.1.2 optixRtnOduScanResultRxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the receive freqencies of frequency scanning. Unit:KHz" ::= { optixRtnOduFreqScanResultEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.70.1.3 optixRtnOduScanResultRxRsl OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the receive power of frequency scanning. Unit:0.1 dBm" ::= { optixRtnOduFreqScanResultEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.80 optixRtnScanFreqTrapCommon OBJECT IDENTIFIER ::= { optixODU 80 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.80.1 optixRptRtnScanFreqEvent OBJECT IDENTIFIER ::= { optixRtnScanFreqTrapCommon 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.80.1.1 optixRtnOduIndexBid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the RF unit board ID." ::= { optixRptRtnScanFreqEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.80.1.2 optixRtnOduIndexSubID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the subboard ID." ::= { optixRptRtnScanFreqEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.80.1.3 optixRptRtnFreqScanState OBJECT-TYPE SYNTAX INTEGER { stopScanFreqStateNormal(0), stopScanFreqStateManual(1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the stop type of frequency scanning." ::= { optixRptRtnScanFreqEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.90 optixRtnScanTrap OBJECT IDENTIFIER ::= { optixODU 90 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.90.1 optixRtnScanFreqTrap NOTIFICATION-TYPE OBJECTS{ optixRtnOduIndexBid,optixRtnOduIndexSubID,optixRptRtnFreqScanState } STATUS current DESCRIPTION "Indicates the finish event of frequency scanning." ::= { optixRtnScanTrap 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.100 optixRtnOduTemplateTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduTemplateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes parameters of the ODU template." ::= { optixODU 100 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.100.1 optixRtnOduTemplateEntry OBJECT-TYPE SYNTAX OptixRtnOduTemplateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the ODU template" INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnOduTemplateTable 1 } OptixRtnOduTemplateEntry ::= SEQUENCE { optixRtnOduTemplate INTEGER } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.100.1.1 optixRtnOduTemplate OBJECT-TYPE SYNTAX INTEGER { relative(0), absolute(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the template of an RF port." DEFVAL{ relative } ::= { optixRtnOduTemplateEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.105 optixRtnOduTypeInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduTypeInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the type of ODU." ::= { optixODU 105 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.105.1 optixRtnOduTypeInfoEntry OBJECT-TYPE SYNTAX OptixRtnOduTypeInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the type of ODU." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnOduTypeInfoTable 1 } OptixRtnOduTypeInfoEntry ::= SEQUENCE { optixRtnLinkReportOduType OCTET STRING, optixRtnEquipOduType OCTET STRING } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.105.1.1 optixRtnLinkReportOduType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of LinkReportODU." ::= { optixRtnOduTypeInfoEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.105.1.2 optixRtnEquipOduType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of EquipODU." ::= { optixRtnOduTypeInfoEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.106 optixRtnOduDuplexInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduDuplexInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Query the device information of ODU duplex." ::= { optixODU 106 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.106.1 optixRtnOduDuplexInfoEntry OBJECT-TYPE SYNTAX OptixRtnOduDuplexInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the device information of ODU duplex." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnOduDuplexInfoTable 1 } OptixRtnOduDuplexInfoEntry ::= SEQUENCE { optixRtnSubFreq INTEGER, optixRtnTRSpacing Unsigned32, optixRtnFreqMin Unsigned32, optixRtnFreqMax Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.106.1.1 optixRtnSubFreq OBJECT-TYPE SYNTAX INTEGER { a(1), b(2), c(3), d(4), e(5), f(6), g(7), h(8), i(9), j(10), k(11), l(12), m(13), n(14), o(15), p(16), q(17), r(18), s(19), t(20), u(21), v(22), w(23), x(24), y(25), z(26) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the subfrequency of ODU duplex." ::= { optixRtnOduDuplexInfoEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.106.1.2 optixRtnTRSpacing OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the TRSpacing of ODU duplex." ::= { optixRtnOduDuplexInfoEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.106.1.3 optixRtnFreqMin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum frequency of ODU duplex." ::= { optixRtnOduDuplexInfoEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.106.1.4 optixRtnFreqMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum frequency of ODU duplex." ::= { optixRtnOduDuplexInfoEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.110 optixRtnCombineTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnCombineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameters of the RFU-SD combination mode." ::= { optixODU 110 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.110.1 optixRtnCombineEntry OBJECT-TYPE SYNTAX OptixRtnCombineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameter entry for the RFU-SD combine mode." INDEX{ optixRtnRFUBid,optixRtnRFUSubCardId } ::= { optixRtnCombineTable 1 } OptixRtnCombineEntry ::= SEQUENCE { optixRtnCombineMode OPTIXRtnCombineMode, optixRtnCombineActualMode OPTIXRtnCombineMode } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.110.1.1 optixRtnCombineMode OBJECT-TYPE SYNTAX OPTIXRtnCombineMode MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the RFU-SD combination mode." DEFVAL{ 2 } ::= { optixRtnCombineEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.110.1.2 optixRtnCombineActualMode OBJECT-TYPE SYNTAX OPTIXRtnCombineMode MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the RFU-SD actual combination mode." ::= { optixRtnCombineEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120 optixRtnSlavePowerTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnSlavePowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameters related to the receive power of the RFU-SD slave port." ::= { optixODU 120 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1 optixRtnSlavePowerEntry OBJECT-TYPE SYNTAX OptixRtnSlavePowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of the power parameters of the RFU-SD slave port." INDEX{ optixRtnRFUBid,optixRtnRFUSubCardId } ::= { optixRtnSlavePowerTable 1 } OptixRtnSlavePowerEntry ::= SEQUENCE { optixRtnSlaveCfgToBeRxPower Integer32, optixRtnSlaveRxPowerHighTh Integer32, optixRtnSlaveRxPowerLowTh Integer32, optixRtnSlaveActualRxPower Integer32, optixRtnMainActualRxPower Integer32, optixRtnRealRxPower Integer32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1.1 optixRtnSlaveCfgToBeRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the power expected to be received of the RFU-SD slave port. The unit is 0.1 dBm." ::= { optixRtnSlavePowerEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1.2 optixRtnSlaveRxPowerHighTh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the upper threshold of the receive power of the RFU-SD slave port.The unit is 0.1 dBm (signed number)." ::= { optixRtnSlavePowerEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1.3 optixRtnSlaveRxPowerLowTh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the lower threshold of the receive power of the RFU-SD slave port.The unit is 0.1 dBm (signed number)." ::= { optixRtnSlavePowerEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1.4 optixRtnSlaveActualRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual receive power of the RFU-SD slave port.The unit is 0.1 dBm (signed number)." ::= { optixRtnSlavePowerEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1.5 optixRtnMainActualRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the actual receive power of the RFU-SD main port.The unit is 0.1 dBm (signed number)." ::= { optixRtnSlavePowerEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.120.1.6 optixRtnRealRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the real receive power of the RFU-SD slave port.The unit is 0.1 dBm (signed number)." ::= { optixRtnSlavePowerEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.130 optixRtnFiberEqualTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnFiberEqualEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameters of the RFU-SD delay compensation." ::= { optixODU 130 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.130.1 optixRtnFiberEqualEntry OBJECT-TYPE SYNTAX OptixRtnFiberEqualEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of the RFU-SD delay compensation parameter." INDEX{ optixRtnRFUBid,optixRtnRFUSubCardId } ::= { optixRtnFiberEqualTable 1 } OptixRtnFiberEqualEntry ::= SEQUENCE { optixRtnFiberEqualState OPTIXRtnFiberEqualState, optixRtnFiberEqualValue Integer32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.130.1.1 optixRtnFiberEqualState OBJECT-TYPE SYNTAX OPTIXRtnFiberEqualState MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the status of the RFU-SD delay compensation." DEFVAL{ start } ::= { optixRtnFiberEqualEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.130.1.2 optixRtnFiberEqualValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the value of the RFU-SD delay compensation." ::= { optixRtnFiberEqualEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.140 optixRtnRFUFrequencyTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnRFUFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the parameters related to the RFU receive frequency." ::= { optixODU 140 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.140.1 optixRtnRFUFrequencyEntry OBJECT-TYPE SYNTAX OptixRtnRFUFrequencyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry of the RFU receive frequency parameter." INDEX{ optixRtnRFUBid,optixRtnRFUSubCardId } ::= { optixRtnRFUFrequencyTable 1 } OptixRtnRFUFrequencyEntry ::= SEQUENCE { optixRtnRFURxFreq Unsigned32, optixRtnRFUMinRxFreq Unsigned32, optixRtnRFUMaxRxFreq Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.140.1.1 optixRtnRFURxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the receive frequency of the RFU. The unit is KHz." ::= { optixRtnRFUFrequencyEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.140.1.2 optixRtnRFUMinRxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the minimum value of the working range of the RFU receive frequencies. The unit is KHz." ::= { optixRtnRFUFrequencyEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.140.1.3 optixRtnRFUMaxRxFreq OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the maximum value of the working range of the RFU receive frequencies. The unit is KHz." ::= { optixRtnRFUFrequencyEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.150 optixRFUTrapCommon OBJECT IDENTIFIER ::= { optixODU 150 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.150.1 optixRFUTrapEvent OBJECT IDENTIFIER ::= { optixRFUTrapCommon 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.150.1.1 optixRptRtnRFUBid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the RFU board." ::= { optixRFUTrapEvent 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.150.1.2 optixRptRtnRFUSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the slot ID of the RFU subboard." ::= { optixRFUTrapEvent 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.150.1.3 optixRptRtnFiberEqualResult OBJECT-TYPE SYNTAX INTEGER { success(0), fail(1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the result of the delay compensation." ::= { optixRFUTrapEvent 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.150.1.4 optixRptRtnFiberEqualValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Indicates the value of the delay compensation." ::= { optixRFUTrapEvent 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.160 optixRtnFiberEqualTrap OBJECT IDENTIFIER ::= { optixODU 160 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.160.1 optixRtnFiberEqualResultTrap NOTIFICATION-TYPE OBJECTS{ optixRptRtnRFUBid,optixRptRtnRFUSubCardId,optixRptRtnFiberEqualResult,optixRptRtnFiberEqualValue } STATUS current DESCRIPTION "Indicates the result of the delay compensation." ::= { optixRtnFiberEqualTrap 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.170 optixRtnRfuIndexTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnRfuIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serves as the public index table for attribute tables related to an RFU." ::= { optixODU 170 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.170.1 optixRtnRfuIndexEntry OBJECT-TYPE SYNTAX OptixRtnRfuIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the index entry for an RFU." INDEX{ optixRtnRFUBid,optixRtnRFUSubCardId } ::= { optixRtnRfuIndexTable 1 } OptixRtnRfuIndexEntry ::= SEQUENCE { optixRtnRFUBid Unsigned32, optixRtnRFUSubCardId Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.170.1.1 optixRtnRFUBid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the RFU board ID." ::= { optixRtnRfuIndexEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.170.1.2 optixRtnRFUSubCardId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the subboard ID." ::= { optixRtnRfuIndexEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.190 optixRtnFlapLinkDownTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnFlapLinkDownEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the flapping-linkdown state." ::= { optixODU 190} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.190.1 optixRtnFlapLinkDownEntry OBJECT-TYPE SYNTAX OptixRtnFlapLinkDownEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the flapping-linkdown state." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2,optixRtnOduIndex3 } ::= { optixRtnFlapLinkDownTable 1 } OptixRtnFlapLinkDownEntry ::= SEQUENCE { optixRtnOduFlapLinkDownStatus Unsigned32, optixRtnOduFlapLinkDownChecktime Unsigned32, optixRtnOduFlapLinkDownFrequency Unsigned32, optixRtnOduFlapLinkRecoveryTime Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.190.1.1 optixRtnOduFlapLinkDownStatus OBJECT-TYPE SYNTAX Unsigned32 { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the flapping-linkdown status,it has two mode type:disable(0),enable(1)." ::= { optixRtnFlapLinkDownEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.190.1.2 optixRtnOduFlapLinkDownChecktime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the check time of flapping-linkdown,enable:30~180,disable:0.Unit:second." ::= { optixRtnFlapLinkDownEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.190.1.3 optixRtnOduFlapLinkDownFrequency OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the freqency of turnning off threshold, enable:3~30,disable:0." ::= { optixRtnFlapLinkDownEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.190.1.4 optixRtnOduFlapLinkRecoveryTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the recoveryTime of flapping-linkdown, enable:0~30,0 represents not automatically recovery,disable:0.Unit:minute." ::= { optixRtnFlapLinkDownEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101 optixRtnOduInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF OptixRtnOduInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Describes ODU information." ::= { optixODU 101} -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1 optixRtnOduInfoEntry OBJECT-TYPE SYNTAX OptixRtnOduInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates an ODU information entry." INDEX{ optixRtnOduIndex1,optixRtnOduIndex2 } ::= { optixRtnOduInfoTable 1 } OptixRtnOduInfoEntry ::= SEQUENCE { optixRtnOduFreqBand Unsigned32, optixRtnOduDeviceType INTEGER, optixRtnOduTRSpacing Unsigned32, optixRtnOduIFBandWidth Unsigned32, optixRtnOduIFBandWidthType INTEGER, optixRtnOduHighorLowStation INTEGER, optixRtnOduPowerType INTEGER, optixRtnOduFactoryCode Unsigned32, optixRtnOduProducedYear Unsigned32, optixRtnOduProducedMonth Unsigned32, optixRtnOduSNCode Unsigned32 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.1 optixRtnOduFreqBand OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the frequency band, expressed in GHz." ::= { optixRtnOduInfoEntry 1 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.2 optixRtnOduDeviceType OBJECT-TYPE SYNTAX INTEGER { highcapacity(5), lowcapacity(10), rfu(11), rfuSd(12), xmc3(13), xmc3w(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ODU device type: 10-Low Capacity 5-High Capacity 11-RFU 12-RFU-SD 13-XMC-3 14-XMC-3W" ::= { optixRtnOduInfoEntry 2 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.3 optixRtnOduTRSpacing OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the T/R spacing, expressed in kHz." ::= { optixRtnOduInfoEntry 3 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.4 optixRtnOduIFBandWidth OBJECT-TYPE SYNTAX Unsigned32 { bw7(7), bw14(14), bw28(28), bw40(40), bw56(56), bw112(112), bw250(150), bw500(151), bw750(152), bw125(153), bw62p5(154), bw200(155) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the supported IF bandwidth. If the value is between 0 and 149, it indicates the actual bandwidth in the unit of MHz. If the value is between 150 and 255, it indicates a mapping index. You need calculate the actual bandwidth using the mapping index. For details about the mapping index, see the remarks." ::= { optixRtnOduInfoEntry 4 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.5 optixRtnOduIFBandWidthType OBJECT-TYPE SYNTAX INTEGER { fixed(0), max(1), zero(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the supported IF bandwidth is variable. The values are as follows: 0: fixed 1: variable" ::= { optixRtnOduInfoEntry 5 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.6 optixRtnOduHighorLowStation OBJECT-TYPE SYNTAX INTEGER { txLow(5), txHigh(10), zero(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether a station is high or low station. 5: Tx-Low (low station) 10: Tx-High (high station) 0: undifferentiated" ::= { optixRtnOduInfoEntry 6 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.7 optixRtnOduPowerType OBJECT-TYPE SYNTAX INTEGER { standard(5), high(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the transmit power type of an ODU. 5: standard output power 10: high output power" ::= { optixRtnOduInfoEntry 7 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.8 optixRtnOduFactoryCode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the vendor code." ::= { optixRtnOduInfoEntry 8 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.9 optixRtnOduProducedYear OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the manufacture year." ::= { optixRtnOduInfoEntry 9 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.10 optixRtnOduProducedMonth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the manufacture month." ::= { optixRtnOduInfoEntry 10 } -- 1.3.6.1.4.1.2011.2.25.4.40.4.10.101.1.11 optixRtnOduSNCode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the production sequence number." ::= { optixRtnOduInfoEntry 11 } END