-- ***************************************************************** -- RUIJIE-SYSTEM-MIB.mib: Ruijie System MIB file -- -- March 2002, Wuzg -- -- Copyright (c) 2002 by Ruijie Networks Co.,Ltd. -- All rights reserved. -- -- ***************************************************************** -- RUIJIE-SYSTEM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, TimeTicks, Unsigned32 FROM SNMPv2-SMI DisplayString, MacAddress FROM SNMPv2-TC Gauge FROM RFC1155-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF ruijieApMacAddr FROM RUIJIE-AC-MGMT-MIB ruijieMemoryPoolCurrentUtilization, ruijieNodeMemoryPoolName, ruijieNodeMemoryPoolCurrentUtilization FROM RUIJIE-MEMORY-MIB ruijieCPUUtilization1Min, Percent, ruijieNodeCPUTotalName, ruijieNodeCPUTotal1min FROM RUIJIE-PROCESS-MIB entPhysicalName FROM ENTITY-MIB ruijieMgmt FROM RUIJIE-SMI; ruijieSystemMIB MODULE-IDENTITY LAST-UPDATED "200203200000Z" ORGANIZATION "Ruijie Networks Co.,Ltd." CONTACT-INFO " Tel: 4008-111-000 E-mail: service@ruijie.com.cn" DESCRIPTION "This module defines ruijie system mibs." REVISION "200203200000Z" DESCRIPTION "Initial version of this MIB module." ::= { ruijieMgmt 1} ruijieSystemMIBObjects OBJECT IDENTIFIER ::= { ruijieSystemMIB 1 } ruijieSystemHwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of hardware resides on the FastSwitch." ::= { ruijieSystemMIBObjects 1 } ruijieSystemSwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of software resides on the FastSwitch." ::= { ruijieSystemMIBObjects 2 } ruijieSystemBootVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of BOOT software resides on the FastSwitch." ::= { ruijieSystemMIBObjects 3 } ruijieSystemSysCtrlVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of CTRL software resides on the FastSwitch." ::= { ruijieSystemMIBObjects 4 } ruijieSystemParametersSave OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Save all parameters changed in configuration by setting this object to any value but 0, set its value to 0 will cause no action of agent, otherwise all changes of prarameters will be saved for retrive when system is reset, if parameter is changed but not saved all changes will come to their original value when system down and up again, when query always return value 0." ::= { ruijieSystemMIBObjects 5 } ruijieSystemOutBandRate OBJECT-TYPE SYNTAX INTEGER { baud9600 (1), baud19200 (2), baud38400 (3), baud57600 (4), baud115200 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determine the console(OutBand) baud rate : 9600 - 1,19200 - 2, 38300 - 3, 57600 - 4, 115200 - 5, when the console baud rate is other value will return value 0." ::= { ruijieSystemMIBObjects 6 } ruijieSystemReset OBJECT-TYPE SYNTAX INTEGER { normal(0), restart(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This Object allow perform soft reset of system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap will send to declare the state and when queried will always return 0." ::= { ruijieSystemMIBObjects 7 } ruijieSwitchLayer OBJECT-TYPE SYNTAX INTEGER { layer2 (1), -- Layer 2 Switch layer3 (2), -- Layer 3 Switch router(3) -- Router } MAX-ACCESS read-only STATUS current DESCRIPTION "Which layer's device the switch in system " ::= { ruijieSystemMIBObjects 8 } ruijieSystemHwPower OBJECT-TYPE SYNTAX INTEGER{ rpsNoLink(1), rpsLinkAndNoPower(2), rpsLinkAndReadyForPower(3), rpsLinkAndPower(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of power." ::= { ruijieSystemMIBObjects 9 } ruijieSystemHwFan OBJECT-TYPE SYNTAX INTEGER{ work(1), stop(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of fan." ::= { ruijieSystemMIBObjects 10 } --The ruijieSystemOutBandTimeout is obsoleted after 2007.9 ruijieSystemOutBandTimeout OBJECT-TYPE SYNTAX Integer32(0..3600) UNITS "seconds" MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The timeout of console.0 indicate that timeout function is disabled." ::= { ruijieSystemMIBObjects 11 } --The ruijieSystemTelnetTimeout is obsoleted after 2007.9 ruijieSystemTelnetTimeout OBJECT-TYPE SYNTAX Integer32(0..3600) UNITS "seconds" MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The timeout of telnet.0 indicate that timeout function is disabled." ::= { ruijieSystemMIBObjects 12 } ruijieSystemMainFile OBJECT-TYPE SYNTAX DisplayString(SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the name of main file on the FastSwitch." ::= { ruijieSystemMIBObjects 13 } ruijieSystemCurrentPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current power of the FastSwitch." ::= { ruijieSystemMIBObjects 14 } ruijieSystemRemainPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the remain power of the FastSwitch." ::= { ruijieSystemMIBObjects 15 } ruijieSystemTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the temperature of the FastSwitch." ::= { ruijieSystemMIBObjects 16 } ruijieSystemElectricalSourceNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the electrical source number of the FastSwitch." ::= { ruijieSystemMIBObjects 17 } ruijieSystemElectricalSourceIsNormalTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemElectricalSourceIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of electrical source entries. Each object displays whether different electrical sources are normal or not." ::= { ruijieSystemMIBObjects 18 } ruijieSystemElectricalSourceIsNormalEntry OBJECT-TYPE SYNTAX RuijieSystemElectricalSourceIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays whether different electrical sources are normal or not." INDEX { ruijieSystemElectricalSourceIsNormalIndex } ::= { ruijieSystemElectricalSourceIsNormalTable 1 } RuijieSystemElectricalSourceIsNormalEntry ::= SEQUENCE { ruijieSystemElectricalSourceIsNormalIndex Integer32, ruijieSystemElectricalSourceIsNormal INTEGER, ruijieSystemElectricalSourceName DisplayString } ruijieSystemElectricalSourceIsNormalIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a electrical source." ::= { ruijieSystemElectricalSourceIsNormalEntry 1 } ruijieSystemElectricalSourceIsNormal OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), --exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6), --unknow linefail (7) --line fail } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an electrical source is normal or not." ::= { ruijieSystemElectricalSourceIsNormalEntry 2 } ruijieSystemElectricalSourceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of electrical source" ::= { ruijieSystemElectricalSourceIsNormalEntry 3 } ruijieSystemCurrentVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current voltage of the FastSwitch." ::= { ruijieSystemMIBObjects 19 } ruijieSystemFanNUM OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the number of fan on the FastSwitch." ::= { ruijieSystemMIBObjects 20 } ruijieSystemFanIsNormalTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan entries. Each object displays whether different fans are normal or not." ::= { ruijieSystemMIBObjects 21 } ruijieSystemFanIsNormalEntry OBJECT-TYPE SYNTAX RuijieSystemFanIsNormalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays whether different fans are normal or not." INDEX { ruijieSystemFanIsNormalIndex } ::= { ruijieSystemFanIsNormalTable 1 } RuijieSystemFanIsNormalEntry ::= SEQUENCE { ruijieSystemFanIsNormalIndex Integer32, ruijieSystemFanIsNormal INTEGER, ruijieSystemFanName DisplayString, ruijieSystemFanSpeed Integer32 } ruijieSystemFanIsNormalIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a fan." ::= { ruijieSystemFanIsNormalEntry 1 } ruijieSystemFanIsNormal OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), --exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6), --unknow linefail (7) --line fail } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an fan is normal or not." ::= { ruijieSystemFanIsNormalEntry 2 } ruijieSystemFanName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of fan" ::= { ruijieSystemFanIsNormalEntry 3 } ruijieSystemFanSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the fan's speed." ::= { ruijieSystemFanIsNormalEntry 4 } ruijieSystemReloadTimeRemain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the remain time of reloading on the FastSwitch." ::= { ruijieSystemMIBObjects 22 } ruijieSystemTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of temperature entries. Each object displays the temperature information." ::= { ruijieSystemMIBObjects 23 } ruijieSystemTemperatureEntry OBJECT-TYPE SYNTAX RuijieSystemTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the temperature information." INDEX { ruijieSystemTemperatureIndex } ::= { ruijieSystemTemperatureTable 1 } RuijieSystemTemperatureEntry ::= SEQUENCE { ruijieSystemTemperatureIndex Integer32, ruijieSystemTemperatureName DisplayString, ruijieSystemTemperatureCurrent Integer32, ruijieSystemTemperatureWarningVaule Integer32, ruijieSystemTemperatureCritialVaule Integer32 } ruijieSystemTemperatureIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's temperature information." ::= { ruijieSystemTemperatureEntry 1 } ruijieSystemTemperatureName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a temperature chip" ::= { ruijieSystemTemperatureEntry 2 } ruijieSystemTemperatureCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0." ::= { ruijieSystemTemperatureEntry 3 } ruijieSystemTemperatureWarningVaule OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The first warning of temperature of the device CPU." ::= { ruijieSystemTemperatureEntry 4 } ruijieSystemTemperatureCritialVaule OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The second warning of temperature of the device CPU." ::= { ruijieSystemTemperatureEntry 5 } ruijieSystemSerialno OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the serial number resides on the FastSwitch. Or return the serial number resides on the current master engine of a chassis device." ::= { ruijieSystemMIBObjects 24 } ruijieSystemVersionTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of system version entries. Each object displays the system version information." ::= { ruijieSystemMIBObjects 25 } ruijieSystemVersionEntry OBJECT-TYPE SYNTAX RuijieSystemVersionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the system version information." INDEX { ruijieSystemVersionIndex } ::= { ruijieSystemVersionTable 1 } RuijieSystemVersionEntry ::= SEQUENCE { ruijieSystemVersionIndex Unsigned32, ruijieSystemVersionName DisplayString, ruijieSystemVersionSwBoot DisplayString, ruijieSystemVersionSwCtrl DisplayString, ruijieSystemVersionSwMain DisplayString, ruijieSystemVersionHw DisplayString, ruijieSystemVersionSerialno DisplayString } ruijieSystemVersionIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's system version information." ::= { ruijieSystemVersionEntry 1 } ruijieSystemVersionName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a system version chip" ::= { ruijieSystemVersionEntry 2 } ruijieSystemVersionSwBoot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software boot system version of the FastSwitch." ::= { ruijieSystemVersionEntry 3 } ruijieSystemVersionSwCtrl OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software ctrl system version of the FastSwitch." ::= { ruijieSystemVersionEntry 4 } ruijieSystemVersionSwMain OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software main system version of the FastSwitch." ::= { ruijieSystemVersionEntry 5 } ruijieSystemVersionHw OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the hardware system version of the FastSwitch." ::= { ruijieSystemVersionEntry 6 } ruijieSystemVersionSerialno OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the serial number of the FastSwitch." ::= { ruijieSystemVersionEntry 7 } --System models added 2010-05 ruijieSystemSysModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SysModel of equipment." ::={ ruijieSystemMIBObjects 26 } ruijieSystemUptime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SysUptime of equipment,unit is seconds." ::={ ruijieSystemMIBObjects 27 } --System Sample Time 2010-05 ruijieSystemSampleTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Sampling duration." ::={ ruijieSystemMIBObjects 28 } ruijieSystemStatWindowTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Stating duration." ::={ ruijieSystemMIBObjects 29 } ruijieSystemManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the manufacturer." ::= { ruijieSystemMIBObjects 30 } ruijieSystemCurrentTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Return the current time of the system." ::= { ruijieSystemMIBObjects 31 } ruijieSystemWarnResendTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the resending time of warn trap of the system." ::= { ruijieSystemMIBObjects 32 } ruijieSystemSoftwareName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software name of the system." ::= { ruijieSystemMIBObjects 33 } ruijieSystemSoftwareManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software manufacturer of the system." ::= { ruijieSystemMIBObjects 34 } ruijieSystemCpuType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the cpu type infomation of the system." ::= { ruijieSystemMIBObjects 35 } ruijieSystemMemoryType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the memory type of the system." ::= { ruijieSystemMIBObjects 36 } ruijieSystemMemorySize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the memory card storage of the system." ::= { ruijieSystemMIBObjects 37 } ruijieSystemFlashSize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the flash size of the system." ::= { ruijieSystemMIBObjects 38 } --lank ap 2010-7 ruijieSystemLankApTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemLankApEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of lank ap system entries. Each object displays the lank ap system information." ::= { ruijieSystemMIBObjects 39 } ruijieSystemLankApEntry OBJECT-TYPE SYNTAX RuijieSystemLankApEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the lank ap system information." INDEX { ruijieSystemLankApMacAddr } ::= { ruijieSystemLankApTable 1 } RuijieSystemLankApEntry ::= SEQUENCE { ruijieSystemLankApMacAddr MacAddress, ruijieSystemLankApStatWindowTime Integer32, ruijieSystemLankApSampleTime Integer32, ruijieSystemLankApReset INTEGER, ruijieSystemLankApSoftwareName DisplayString, ruijieSystemLankApSwVersion DisplayString, ruijieSystemLankApSoftwareManufacturer DisplayString, ruijieSystemLankApCpuType DisplayString, ruijieSystemLankApMemoryType DisplayString, ruijieSystemLankApMemorySize Gauge, ruijieSystemLankAPFlashSize Gauge, ruijieSystemLankApManufacturer DisplayString, ruijieSystemLankApSerialno DisplayString, ruijieSystemLankApSysModel DisplayString, ruijieSystemLankApUptime INTEGER, ruijieSystemLankApAccurateUptime TimeTicks, ruijieSystemLankApHwVersion DisplayString } ruijieSystemLankApMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents lank ap system information." ::= { ruijieSystemLankApEntry 1 } ruijieSystemLankApStatWindowTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Stating duration of lank ap." ::={ ruijieSystemLankApEntry 2 } ruijieSystemLankApSampleTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Sampling duration of lank ap." ::={ ruijieSystemLankApEntry 3 } ruijieSystemLankApReset OBJECT-TYPE SYNTAX INTEGER { normal(0), restart(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This Object allow perform soft reset of lank ap system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap will send to declare the state and when queried will always return 0." ::= { ruijieSystemLankApEntry 4 } ruijieSystemLankApSoftwareName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software name of the lank ap system." ::= { ruijieSystemLankApEntry 5 } ruijieSystemLankApSwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of software resides on the lank ap FastSwitch." ::= { ruijieSystemLankApEntry 6 } ruijieSystemLankApSoftwareManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the software manufacturer of the lank ap system." ::= { ruijieSystemLankApEntry 7 } ruijieSystemLankApCpuType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the cpu type infomation of the lank ap system." ::= { ruijieSystemLankApEntry 8 } ruijieSystemLankApMemoryType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the memory type of the lank ap system." ::= { ruijieSystemLankApEntry 9 } ruijieSystemLankApMemorySize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the memory card storage of the lank ap system." ::= { ruijieSystemLankApEntry 10 } ruijieSystemLankAPFlashSize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the flash size of the lank ap system." ::= { ruijieSystemLankApEntry 11 } ruijieSystemLankApManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the manufacturer of lank ap." ::= { ruijieSystemLankApEntry 12} ruijieSystemLankApSerialno OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the serial number resides on the lank ap FastSwitch." ::= { ruijieSystemLankApEntry 13 } ruijieSystemLankApSysModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SysModel of lank ap equipment." ::={ ruijieSystemLankApEntry 14 } ruijieSystemLankApUptime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SysUptime of lank ap equipment." ::={ ruijieSystemLankApEntry 15 } ruijieSystemLankApAccurateUptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Return the accurate system Uptime of ap equipment,unit is ticks" ::={ ruijieSystemLankApEntry 16 } ruijieSystemLankApHwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the Revision number of hardware resides on the lank ap FastSwitch." ::= { ruijieSystemLankApEntry 17 } ruijieSystemBoardTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemBoardTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of board temperature entries. Each object displays the board temperature information." ::= { ruijieSystemMIBObjects 40 } ruijieSystemBoardTemperatureEntry OBJECT-TYPE SYNTAX RuijieSystemBoardTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the board temperature information." INDEX { ruijieSystemBoardTemperatureIndex } ::= { ruijieSystemBoardTemperatureTable 1 } RuijieSystemBoardTemperatureEntry ::= SEQUENCE { ruijieSystemBoardTemperatureIndex Integer32, ruijieSystemBoardTemperatureName DisplayString, ruijieSystemBoardTemperatureCurrent Integer32 } ruijieSystemBoardTemperatureIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's board temperature information." ::= { ruijieSystemBoardTemperatureEntry 1 } ruijieSystemBoardTemperatureName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a board temperature chip" ::= { ruijieSystemBoardTemperatureEntry 2 } ruijieSystemBoardTemperatureCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current board temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0." ::= { ruijieSystemBoardTemperatureEntry 3 } ruijieSystemElectricalInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemElectricalInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of electrical entries. Each object displays the electrical information." ::= { ruijieSystemMIBObjects 41 } ruijieSystemElectricalInformationEntry OBJECT-TYPE SYNTAX RuijieSystemElectricalInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the electrical information." INDEX {ruijieSystemElectricalInformationDeviceIndex, ruijieSystemElectricalInformationIndex } ::= { ruijieSystemElectricalInformationTable 1 } RuijieSystemElectricalInformationEntry ::= SEQUENCE { ruijieSystemElectricalInformationDeviceIndex Integer32, ruijieSystemElectricalInformationIndex Integer32, ruijieSystemElectricalInformationStatus INTEGER, ruijieSystemElectricalInformationType DisplayString, ruijieSystemElectricalInformationAttribute DisplayString, ruijieSystemElectricalInformationSofeVersion DisplayString, ruijieSystemElectricalInformationHardwareVersion DisplayString, ruijieSystemElectricalInformationSerial DisplayString, ruijieSystemElectricalInformationProductionDate DisplayString, ruijieSystemElectricalInformationRatedPower Integer32, ruijieSystemElectricalInformationInVoltage Integer32, ruijieSystemElectricalInformationInCurrent Integer32, ruijieSystemElectricalInformationOutVoltage Integer32, ruijieSystemElectricalInformationOutCurrent Integer32, ruijieSystemElectricalInformationOutPower Integer32, ruijieSystemElectricalInformationTemperature Integer32, ruijieSystemElectricalInformationAirflowCoexist DisplayString, ruijieSystemElectricalInformationWarningStatus DisplayString, ruijieSystemElectricalInformationMode DisplayString } ruijieSystemElectricalInformationDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemElectricalInformationEntry 1 } ruijieSystemElectricalInformationIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a electriacl." ::= { ruijieSystemElectricalInformationEntry 2 } ruijieSystemElectricalInformationStatus OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), -- exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6) --unknow } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an electrical source is normal or not. If the electrical is no exist, the other of electrical information maybe return nothing information and 0." ::= { ruijieSystemElectricalInformationEntry 3 } ruijieSystemElectricalInformationType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the type of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 4 } ruijieSystemElectricalInformationAttribute OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays attribute of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 5 } ruijieSystemElectricalInformationSofeVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the sofe version of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 6} ruijieSystemElectricalInformationHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the hardware version of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 7 } ruijieSystemElectricalInformationSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the serial of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 8 } ruijieSystemElectricalInformationProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the productiron date of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 9 } ruijieSystemElectricalInformationRatedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the rated power(Unit: W) of the electrical. If the device is no support this information, This object will return 0." ::= { ruijieSystemElectricalInformationEntry 10 } ruijieSystemElectricalInformationInVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the input voltage(Unit: V) of the electrical. If the device is no support this information, This object will return 0." ::= { ruijieSystemElectricalInformationEntry 11 } ruijieSystemElectricalInformationInCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the input current(Unit: mA) of the electrical. If the device is no support this information, This object will return 0." ::= { ruijieSystemElectricalInformationEntry 12 } ruijieSystemElectricalInformationOutVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the output voltage(Unit: mV) of the electrical. If the device is no support this information, This object will return 0." ::= { ruijieSystemElectricalInformationEntry 13 } ruijieSystemElectricalInformationOutCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the output current(Unit: mA) of the electrical. If the device is no support this information, This object will return 0." ::= { ruijieSystemElectricalInformationEntry 14 } ruijieSystemElectricalInformationOutPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the output power(Unit: mW) of the electrical. If the device is no support this information, This object will return 0." ::= { ruijieSystemElectricalInformationEntry 15 } ruijieSystemElectricalInformationTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the temperature(Unit: C) of the electrical. If the device is no support this information, This object will return -255." ::= { ruijieSystemElectricalInformationEntry 16 } ruijieSystemElectricalInformationAirflowCoexist OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the airflow coexist of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 17 } ruijieSystemElectricalInformationWarningStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the warning status of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 18 } ruijieSystemElectricalInformationMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the mode of the electrical. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemElectricalInformationEntry 19 } ruijieSystemFanInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan entries. Each object displays the fan information." ::= { ruijieSystemMIBObjects 42 } ruijieSystemFanInformationEntry OBJECT-TYPE SYNTAX RuijieSystemFanInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the fan information." INDEX { ruijieSystemFanInformationDeviceIndex , ruijieSystemFanInformationFanIndex} ::= {ruijieSystemFanInformationTable 1 } RuijieSystemFanInformationEntry ::= SEQUENCE { ruijieSystemFanInformationDeviceIndex Integer32, ruijieSystemFanInformationFanIndex Integer32, ruijieSystemFanInformationStatus INTEGER, ruijieSystemFanInformationType DisplayString, ruijieSystemFanInformationAttribute DisplayString, ruijieSystemFanInformationSofeVersion DisplayString, ruijieSystemFanInformationFirmwareVersion DisplayString, ruijieSystemFanInformationHardwareVersion DisplayString, ruijieSystemFanInformationSerial DisplayString, ruijieSystemFanInformationProductionDate DisplayString, ruijieSystemFanInformationTemperature Integer32, ruijieSystemFanInformationNumber Integer32, ruijieSystemFanInformationAirflowCoexist DisplayString, ruijieSystemFanInformationWarningStatus DisplayString } ruijieSystemFanInformationDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemFanInformationEntry 1 } ruijieSystemFanInformationFanIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a fan device." ::= { ruijieSystemFanInformationEntry 2 } ruijieSystemFanInformationStatus OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), --exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6), --unknow linefail (7) --line fail } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an fan device source is exist or not. If the fan device is no exist, the other of fan information maybe return nothing information and 0." ::= { ruijieSystemFanInformationEntry 3 } ruijieSystemFanInformationType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the type of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 4 } ruijieSystemFanInformationAttribute OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays attribute of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 5 } ruijieSystemFanInformationSofeVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the sofe version of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 6} ruijieSystemFanInformationFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the firmware version of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 7 } ruijieSystemFanInformationHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the hardware version of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 8 } ruijieSystemFanInformationSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the serial of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 9 } ruijieSystemFanInformationProductionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the productiron date of the fan. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 10 } ruijieSystemFanInformationTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the temperature of the fan device. If the device is no support this information, This object will return -255." ::= { ruijieSystemFanInformationEntry 11 } ruijieSystemFanInformationNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the number of the fan device. If the device is no support this information, This object will return 0." ::= { ruijieSystemFanInformationEntry 12 } ruijieSystemFanInformationAirflowCoexist OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the airflow coexist of the fan device. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 13 } ruijieSystemFanInformationWarningStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the warning status of the fan device. If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanInformationEntry 14 } ruijieSystemFanStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan status entries. Each object displays the fan status information." ::= { ruijieSystemMIBObjects 43 } ruijieSystemFanStatusEntry OBJECT-TYPE SYNTAX RuijieSystemFanStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the fan status information." INDEX { ruijieSystemFanStatusDeviceIndex, ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex } ::= {ruijieSystemFanStatusTable 1 } RuijieSystemFanStatusEntry ::= SEQUENCE { ruijieSystemFanStatusDeviceIndex Integer32, ruijieSystemFanStatusFanIndex Integer32, ruijieSystemFanStatusIndex Integer32, ruijieSystemFanStatus INTEGER, ruijieSystemFanStatusLevel Integer32, ruijieSystemFanStatusSpeed Integer32 } ruijieSystemFanStatusDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemFanStatusEntry 1 } ruijieSystemFanStatusFanIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a fan device." ::= { ruijieSystemFanStatusEntry 2 } ruijieSystemFanStatusIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a fan." ::= { ruijieSystemFanStatusEntry 3 } ruijieSystemFanStatus OBJECT-TYPE SYNTAX INTEGER { noexist (1), --no exist existnopower (2), --exist no power existreadypower (3), --exist ready power normal (4), --normal powerbutabnormal (5), --power but abnormal unknow (6) --unknow } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether an fan is normal or not." ::= { ruijieSystemFanStatusEntry 4 } ruijieSystemFanStatusLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the level of the fan speed. If the device is no support this information, This object will return 0." ::= { ruijieSystemFanStatusEntry 5 } ruijieSystemFanStatusSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays fan speed(rpm). If the device is no support this information, This object will return nothing information." ::= { ruijieSystemFanStatusEntry 6 } ruijieSystemMultipleTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemMultipleTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of multiple temperature entries. Each object displays the multiple temperature information." ::= { ruijieSystemMIBObjects 44 } ruijieSystemMultipleTemperatureEntry OBJECT-TYPE SYNTAX RuijieSystemMultipleTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the multiple temperature information." INDEX { ruijieSystemMultipleTemperatureDeviceIndex, ruijieSystemMultipleTemperatureSlotIndex, ruijieSystemMultipleTemperatureIndex } ::= { ruijieSystemMultipleTemperatureTable 1 } RuijieSystemMultipleTemperatureEntry ::= SEQUENCE { ruijieSystemMultipleTemperatureDeviceIndex Integer32, ruijieSystemMultipleTemperatureSlotIndex Integer32, ruijieSystemMultipleTemperatureIndex Integer32, ruijieSystemMultipleTemperatureName DisplayString, ruijieSystemMultipleTemperatureCurrent Integer32, ruijieSystemMultipleTemperatureWarning Integer32, ruijieSystemMultipleTemperatureCritical Integer32, ruijieSystemMultipleTemperatureStatus INTEGER } ruijieSystemMultipleTemperatureDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemMultipleTemperatureEntry 1 } ruijieSystemMultipleTemperatureSlotIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a slot device." ::= { ruijieSystemMultipleTemperatureEntry 2 } ruijieSystemMultipleTemperatureIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's multiple temperature information." ::= { ruijieSystemMultipleTemperatureEntry 3 } ruijieSystemMultipleTemperatureName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a multiple temperature chip" ::= { ruijieSystemMultipleTemperatureEntry 4 } ruijieSystemMultipleTemperatureCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current multiple temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to -255." ::= { ruijieSystemMultipleTemperatureEntry 5 } ruijieSystemMultipleTemperatureWarning OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the warning multiple temperature of the FastSwitch.The temperature display is not supported for the warning temperature returns to -255." ::= { ruijieSystemMultipleTemperatureEntry 6 } ruijieSystemMultipleTemperatureCritical OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the critical multiple temperature of the FastSwitch.The temperature display is not supported for the critical temperature returns to -255." ::= { ruijieSystemMultipleTemperatureEntry 7 } ruijieSystemMultipleTemperatureStatus OBJECT-TYPE SYNTAX INTEGER { ok (1), --status ok warning (2), --status warning critical (3), --status critical fail (4) --status fail } MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays whether the temperature is normal or not." ::= { ruijieSystemMultipleTemperatureEntry 8 } ruijieSystemAccurateUptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Return the accurate system Uptime of equipment,unit is ticks." ::={ ruijieSystemMIBObjects 45 } ruijieSystemPowerIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Index of power" ::= { ruijieSystemMIBObjects 46 } ruijieSystemSwitchID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Switch id in VSU" ::= { ruijieSystemMIBObjects 47 } ruijieSystemApDeviceDescriptionTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemApDeviceDescriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of lank ap system entries. Each object displays the lank ap system information." ::= { ruijieSystemMIBObjects 48 } ruijieSystemApDeviceDescriptionEntry OBJECT-TYPE SYNTAX RuijieSystemApDeviceDescriptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the ap Device Description." INDEX { ruijieSystemApDescMacAddr } ::= { ruijieSystemApDeviceDescriptionTable 1 } RuijieSystemApDeviceDescriptionEntry ::= SEQUENCE { ruijieSystemApDescMacAddr MacAddress, ruijieSystemApMemoryType INTEGER, ruijieSystemApMemorySize Gauge, ruijieSystemAPFlashType INTEGER, ruijieSystemAPFlashSize Gauge, ruijieSystemApNVRAMSize Gauge, ruijieSystemApCFSize Gauge, ruijieSystemApCPUType DisplayString } ruijieSystemApDescMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents ap system information." ::= { ruijieSystemApDeviceDescriptionEntry 1 } ruijieSystemApMemoryType OBJECT-TYPE SYNTAX INTEGER { reserved(0), sdram(1), ddram(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Return the memory type of the lank ap system." ::= { ruijieSystemApDeviceDescriptionEntry 2 } ruijieSystemApMemorySize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the memory card storage of the lank ap system, unit is MB." ::= { ruijieSystemApDeviceDescriptionEntry 3 } ruijieSystemAPFlashType OBJECT-TYPE SYNTAX INTEGER { reserved(0), nor(1), non-nor(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents ap system information." ::= { ruijieSystemApDeviceDescriptionEntry 4 } ruijieSystemAPFlashSize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the flash size of the lank ap system, unit is MB." ::= { ruijieSystemApDeviceDescriptionEntry 5 } ruijieSystemApNVRAMSize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the NVRAM size of the lank ap system, unit is MB." ::= { ruijieSystemApDeviceDescriptionEntry 6 } ruijieSystemApCFSize OBJECT-TYPE SYNTAX Gauge MAX-ACCESS read-only STATUS current DESCRIPTION "Return the CF size of the lank ap system, unit is MB." ::= { ruijieSystemApDeviceDescriptionEntry 7 } ruijieSystemApCPUType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the cpu type of the lank ap system." ::= { ruijieSystemApDeviceDescriptionEntry 8 } ruijieSystemApDeviceStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemApDeviceStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of lank ap system entries. Each object displays the lank ap system information." ::= { ruijieSystemMIBObjects 49 } ruijieSystemApDeviceStatisticsEntry OBJECT-TYPE SYNTAX RuijieSystemApDeviceStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the ap Device Statistics." INDEX { ruijieSystemApStatMacAddr } ::= { ruijieSystemApDeviceStatisticsTable 1 } RuijieSystemApDeviceStatisticsEntry ::= SEQUENCE { ruijieSystemApStatMacAddr MacAddress, ruijieSystemApInterfaceNum Integer32, ruijieSystemApUptime TimeTicks, ruijieSystemApCPUUtilizationCurrent Percent, ruijieSystemApCPUUtilizationAverage Percent, ruijieSystemApMemoryPoolCurrentUtilization Percent, ruijieSystemApMemoryPoolAverageUtilization Percent, ruijieSystemApFlashFreeSize Unsigned32, ruijieSystemAPDeviceTemperature Integer32 } ruijieSystemApStatMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents ap system information." ::= { ruijieSystemApDeviceStatisticsEntry 1 } ruijieSystemApInterfaceNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the interface number of the lank ap system." ::= { ruijieSystemApDeviceStatisticsEntry 2 } ruijieSystemApUptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SysUptime of lank ap equipment, unit is ticks." ::= { ruijieSystemApDeviceStatisticsEntry 3 } ruijieSystemApCPUUtilizationCurrent OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "This is the collection of current lank ap cpu using rate." ::= { ruijieSystemApDeviceStatisticsEntry 4 } ruijieSystemApCPUUtilizationAverage OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "This is the average cpu using rate currently." ::= { ruijieSystemApDeviceStatisticsEntry 5 } ruijieSystemApMemoryPoolCurrentUtilization OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "This is the memory pool utilization currently." ::= { ruijieSystemApDeviceStatisticsEntry 6 } ruijieSystemApMemoryPoolAverageUtilization OBJECT-TYPE SYNTAX Percent MAX-ACCESS read-only STATUS current DESCRIPTION "This is the average memory pool utilization currently." ::= { ruijieSystemApDeviceStatisticsEntry 7 } ruijieSystemApFlashFreeSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the free size of the flash device, unit is MB." ::= { ruijieSystemApDeviceStatisticsEntry 8 } ruijieSystemAPDeviceTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the temperature of the ap.But the ap is no support this information, so it will return 35 in perpetuity" ::= { ruijieSystemApDeviceStatisticsEntry 9 } ruijieSystemUptimeMsLow OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the equipment SysUptime Low 32-bit,unit is tick." ::={ ruijieSystemMIBObjects 50 } ruijieSystemUptimeMsHigh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the equipment SysUptime High 32-bit,unit is tick." ::={ ruijieSystemMIBObjects 51 } ruijieSystemFanSNTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanSNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan's serial number" ::= { ruijieSystemMIBObjects 52 } ruijieSystemFanSNEntry OBJECT-TYPE SYNTAX RuijieSystemFanSNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays fan SN." INDEX { ruijieSystemFanPadIndex } ::= { ruijieSystemFanSNTable 1 } RuijieSystemFanSNEntry ::= SEQUENCE { ruijieSystemFanPadIndex Integer32, ruijieSystemFanPadName DisplayString, ruijieSystemFanPadSN DisplayString } ruijieSystemFanPadIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the index of the fan pad." ::= { ruijieSystemFanSNEntry 1 } ruijieSystemFanPadName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the name of the fan pad." ::= { ruijieSystemFanSNEntry 2 } ruijieSystemFanPadSN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SN of the fan pad." ::= { ruijieSystemFanSNEntry 3 } ruijieSystemDsfSNTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemDsfSNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of dsf's serial number" ::= { ruijieSystemMIBObjects 53 } ruijieSystemDsfSNEntry OBJECT-TYPE SYNTAX RuijieSystemDsfSNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays dsf SN." INDEX { ruijieSystemDsfIndex } ::= { ruijieSystemDsfSNTable 1 } RuijieSystemDsfSNEntry ::= SEQUENCE { ruijieSystemDsfIndex Integer32, ruijieSystemDsfName DisplayString, ruijieSystemDsfSN DisplayString } ruijieSystemDsfIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the index of the dsf." ::= { ruijieSystemDsfSNEntry 1 } ruijieSystemDsfName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the name of the dsf." ::= { ruijieSystemDsfSNEntry 2 } ruijieSystemDsfSN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SN of the dsf." ::= { ruijieSystemDsfSNEntry 3 } ruijieSystemPowerSNTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemPowerSNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of power's serial number" ::= { ruijieSystemMIBObjects 54 } ruijieSystemPowerSNEntry OBJECT-TYPE SYNTAX RuijieSystemPowerSNEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays power SN." INDEX { ruijieSystemPowerSNIndex } ::= { ruijieSystemPowerSNTable 1 } RuijieSystemPowerSNEntry ::= SEQUENCE { ruijieSystemPowerSNIndex Integer32, ruijieSystemPowerSNName DisplayString, ruijieSystemPowerSN DisplayString } ruijieSystemPowerSNIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the index of the power." ::= { ruijieSystemPowerSNEntry 1 } ruijieSystemPowerSNName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the name of the power." ::= { ruijieSystemPowerSNEntry 2 } ruijieSystemPowerSN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the SN of the power." ::= { ruijieSystemPowerSNEntry 3 } ruijieSystemFanPad1SpeedTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanPad1SpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan's speed on fan pad1." ::= { ruijieSystemMIBObjects 55 } ruijieSystemFanPad1SpeedEntry OBJECT-TYPE SYNTAX RuijieSystemFanPad1SpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays fan's speed on same fan pad" INDEX { ruijieSystemOamFanPad1Index } ::= { ruijieSystemFanPad1SpeedTable 1 } RuijieSystemFanPad1SpeedEntry ::= SEQUENCE { ruijieSystemOamFanPad1Index Integer32, ruijieSystemOamFanPad1Name DisplayString, ruijieSystemFanPad1Speed1 Integer32, ruijieSystemFanPad1Speed2 Integer32, ruijieSystemFanPad1Speed3 Integer32, ruijieSystemFanPad1Speed4 Integer32, ruijieSystemFanPad1Speed5 Integer32, ruijieSystemFanPad1Speed6 Integer32, ruijieSystemFanPad1Speed7 Integer32, ruijieSystemFanPad1Speed8 Integer32, ruijieSystemFanPad1Speed9 Integer32 } ruijieSystemOamFanPad1Index OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the index of the fan pad." ::= { ruijieSystemFanPad1SpeedEntry 1 } ruijieSystemOamFanPad1Name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the name of the fan pad." ::= { ruijieSystemFanPad1SpeedEntry 2 } ruijieSystemFanPad1Speed1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan1." ::= { ruijieSystemFanPad1SpeedEntry 3 } ruijieSystemFanPad1Speed2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan2." ::= { ruijieSystemFanPad1SpeedEntry 4 } ruijieSystemFanPad1Speed3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan3." ::= { ruijieSystemFanPad1SpeedEntry 5 } ruijieSystemFanPad1Speed4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan4." ::= { ruijieSystemFanPad1SpeedEntry 6 } ruijieSystemFanPad1Speed5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan5." ::= { ruijieSystemFanPad1SpeedEntry 7 } ruijieSystemFanPad1Speed6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan6." ::= { ruijieSystemFanPad1SpeedEntry 8 } ruijieSystemFanPad1Speed7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan7." ::= { ruijieSystemFanPad1SpeedEntry 9 } ruijieSystemFanPad1Speed8 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan8." ::= { ruijieSystemFanPad1SpeedEntry 10 } ruijieSystemFanPad1Speed9 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan9." ::= { ruijieSystemFanPad1SpeedEntry 11 } ruijieSystemFanPad2SpeedTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanPad2SpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan's speed on fan pad2." ::= { ruijieSystemMIBObjects 56 } ruijieSystemFanPad2SpeedEntry OBJECT-TYPE SYNTAX RuijieSystemFanPad2SpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays fan's speed on same fan pad2" INDEX { ruijieSystemOamFanPad2Index } ::= { ruijieSystemFanPad2SpeedTable 1 } RuijieSystemFanPad2SpeedEntry ::= SEQUENCE { ruijieSystemOamFanPad2Index Integer32, ruijieSystemOamFanPad2Name DisplayString, ruijieSystemFanPad2Speed1 Integer32, ruijieSystemFanPad2Speed2 Integer32, ruijieSystemFanPad2Speed3 Integer32 } ruijieSystemOamFanPad2Index OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the index of the fan pad2." ::= { ruijieSystemFanPad2SpeedEntry 1 } ruijieSystemOamFanPad2Name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the name of the fan pad." ::= { ruijieSystemFanPad2SpeedEntry 2 } ruijieSystemFanPad2Speed1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan1." ::= { ruijieSystemFanPad2SpeedEntry 3 } ruijieSystemFanPad2Speed2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan2." ::= { ruijieSystemFanPad2SpeedEntry 4 } ruijieSystemFanPad2Speed3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan3." ::= { ruijieSystemFanPad2SpeedEntry 5 } ruijieSystemFanPad3SpeedTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemFanPad3SpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of fan's speed on fan pad3." ::= { ruijieSystemMIBObjects 57 } ruijieSystemFanPad3SpeedEntry OBJECT-TYPE SYNTAX RuijieSystemFanPad3SpeedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays fan's speed on same fan pad3" INDEX { ruijieSystemOamFanPad3Index } ::= { ruijieSystemFanPad3SpeedTable 1 } RuijieSystemFanPad3SpeedEntry ::= SEQUENCE { ruijieSystemOamFanPad3Index Integer32, ruijieSystemOamFanPad3Name DisplayString, ruijieSystemFanPad3Speed1 Integer32, ruijieSystemFanPad3Speed2 Integer32, ruijieSystemFanPad3Speed3 Integer32, ruijieSystemFanPad3Speed4 Integer32, ruijieSystemFanPad3Speed5 Integer32 } ruijieSystemOamFanPad3Index OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Return the index of the fan pad3." ::= { ruijieSystemFanPad3SpeedEntry 1 } ruijieSystemOamFanPad3Name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the name of the fan pad." ::= { ruijieSystemFanPad3SpeedEntry 2 } ruijieSystemFanPad3Speed1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan1." ::= { ruijieSystemFanPad3SpeedEntry 3 } ruijieSystemFanPad3Speed2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan2." ::= { ruijieSystemFanPad3SpeedEntry 4 } ruijieSystemFanPad3Speed3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan3." ::= { ruijieSystemFanPad3SpeedEntry 5 } ruijieSystemFanPad3Speed4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan4." ::= { ruijieSystemFanPad3SpeedEntry 6 } ruijieSystemFanPad3Speed5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the speed of the fan5." ::= { ruijieSystemFanPad3SpeedEntry 7 } ruijieSystemParamSaveErrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Param Save Err Idx." ::= { ruijieSystemMIBObjects 58 } ruijieSystemParamSaveErrMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Param Save Err Msg." ::= { ruijieSystemMIBObjects 59 } ruijieSystemDeviceLevel OBJECT-TYPE SYNTAX INTEGER { unknown (0), -- Unknown Layer core (1), -- Core Layer collect (2), -- Collect Layer access (3) -- Access Layer } MAX-ACCESS read-write STATUS current DESCRIPTION "This object can display or set which device application level the device belongs to." ::= { ruijieSystemMIBObjects 60 } ruijieSystemSysmac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Sysmac of the system." ::= { ruijieSystemMIBObjects 61 } ruijieSystemDeviceMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Device mode of the system. Only support in all-in-one device." ::= { ruijieSystemMIBObjects 62 } --add card power consume info ruijieSystemCardPowerConsumeTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemCardPowerConsumeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of card power consume entries. Each object displays the card power consume information." ::= { ruijieSystemMIBObjects 63 } ruijieSystemCardPowerConsumeEntry OBJECT-TYPE SYNTAX RuijieSystemCardPowerConsumeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the card power consume information." INDEX { ruijieSystemCardPowerConsumeDeviceIndex, ruijieSystemCardPowerConsumeSlotIndex} ::= {ruijieSystemCardPowerConsumeTable 1 } RuijieSystemCardPowerConsumeEntry ::= SEQUENCE { ruijieSystemCardPowerConsumeDeviceIndex Integer32, ruijieSystemCardPowerConsumeSlotIndex Integer32, ruijieSystemCardPowerVoltage Integer32, ruijieSystemCardPowerCurrent Integer32, ruijieSystemCardPowerConsume Integer32 } ruijieSystemCardPowerConsumeDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemCardPowerConsumeEntry 1 } ruijieSystemCardPowerConsumeSlotIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a slot device." ::= { ruijieSystemCardPowerConsumeEntry 2 } ruijieSystemCardPowerVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the power voltage(Unit: mV) of the slot device. If the device is no support this information, This object will return -255." ::= { ruijieSystemCardPowerConsumeEntry 3 } ruijieSystemCardPowerCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the power current(Unit: mA) of the slot device. If the device is no support this information, This object will return -255." ::= { ruijieSystemCardPowerConsumeEntry 4 } ruijieSystemCardPowerConsume OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object displays the power consume(Unit: W) of the slot device. If the device is no support this information, This object will return -255." ::= { ruijieSystemCardPowerConsumeEntry 5 } ruijieSystemPowerInsertNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the number of inserted power on the FastSwitch." ::= { ruijieSystemMIBObjects 64 } ruijieSystemPowerOnlineNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the number of online power that state is normal on the FastSwitch." ::= { ruijieSystemMIBObjects 65 } ruijieSystemPowerOfflineNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the number of offline power that state is abnormal on the FastSwitch." ::= { ruijieSystemMIBObjects 66 } ruijieSystemPowerRedun OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the redundancy of power on the FastSwitch." ::= { ruijieSystemMIBObjects 67 } ruijieSystemTotalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the total power of the FastSwitch." ::= { ruijieSystemMIBObjects 68 } ruijieSystemAvailablePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the available power of the FastSwitch." ::= { ruijieSystemMIBObjects 69 } ruijieSystemCardAllocatedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the card allocated power of the FastSwitch." ::= { ruijieSystemMIBObjects 70 } ruijieSystemFanAllocatedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the fan allocated power of the FastSwitch." ::= { ruijieSystemMIBObjects 71 } ruijieSystemCardPowerUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the card power used of the FastSwitch." ::= { ruijieSystemMIBObjects 72 } ruijieSystemFanPowerUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the fan power used of the FastSwitch." ::= { ruijieSystemMIBObjects 73 } ruijieSystemFanMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the mode of fan on the FastSwitch." ::= { ruijieSystemMIBObjects 74 } ruijieSystemStartupGmChssSerialno OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Return the string of the serial number of the startup master's chassis." ::= { ruijieSystemMIBObjects 75 } ruijieSystemDeviceTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemDeviceTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of temperature entries. Each object displays the temperature information." ::= { ruijieSystemMIBObjects 76 } ruijieSystemDeviceTemperatureEntry OBJECT-TYPE SYNTAX RuijieSystemDeviceTemperatureEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the multiple temperature information." INDEX { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } ::= { ruijieSystemDeviceTemperatureTable 1 } RuijieSystemDeviceTemperatureEntry ::= SEQUENCE { ruijieSystemDeviceTemperatureDeviceIndex Integer32, ruijieSystemDeviceTemperatureSlotIndex Integer32, ruijieSystemDeviceTemperatureSubSlotIndex Integer32, ruijieSystemDeviceTemperatureIndex Integer32, ruijieSystemDeviceTemperatureName DisplayString, ruijieSystemDeviceTemperatureCurrent Integer32, ruijieSystemDeviceTemperatureWarning Integer32, ruijieSystemDeviceTemperatureCritical Integer32, ruijieSystemDeviceTemperatureShutdown Integer32, ruijieSystemDeviceTemperaturePoweroff Integer32 } ruijieSystemDeviceTemperatureDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemDeviceTemperatureEntry 1 } ruijieSystemDeviceTemperatureSlotIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a slot device." ::= { ruijieSystemDeviceTemperatureEntry 2 } ruijieSystemDeviceTemperatureSubSlotIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a sub slot device." ::= { ruijieSystemDeviceTemperatureEntry 3 } ruijieSystemDeviceTemperatureIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's temperature information." ::= { ruijieSystemDeviceTemperatureEntry 4 } ruijieSystemDeviceTemperatureName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a temperature chip" ::= { ruijieSystemDeviceTemperatureEntry 5 } ruijieSystemDeviceTemperatureCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current device temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to -255." ::= { ruijieSystemDeviceTemperatureEntry 6 } ruijieSystemDeviceTemperatureWarning OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the warning device temperature of the FastSwitch.The temperature display is not supported for the warning temperature returns to -255." ::= { ruijieSystemDeviceTemperatureEntry 7 } ruijieSystemDeviceTemperatureCritical OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the critical device temperature of the FastSwitch.The temperature display is not supported for the critical temperature returns to -255." ::= { ruijieSystemDeviceTemperatureEntry 8 } ruijieSystemDeviceTemperatureShutdown OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the shutdown device temperature of the FastSwitch.The temperature display is not supported for the shutdown temperature returns to -255." ::= { ruijieSystemDeviceTemperatureEntry 9 } ruijieSystemDeviceTemperaturePoweroff OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Return the poweroff device temperature of the FastSwitch.The temperature display is not supported for the poweroff temperature returns to -255." ::= { ruijieSystemDeviceTemperatureEntry 10 } ruijieSystemDeviceModelInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemDeviceModelInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of device model entries. Each object displays the model information." ::= { ruijieSystemMIBObjects 77 } ruijieSystemVacConfigDiffMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (1..255)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Vac Config Diff Msg." ::= { ruijieSystemMIBObjects 78 } ruijieSystemDeviceModelInformationEntry OBJECT-TYPE SYNTAX RuijieSystemDeviceModelInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the multiple model information." INDEX { ruijieSystemDeviceModelInformationDeviceIndex, ruijieSystemDeviceModelInformationSlotIndex, ruijieSystemDeviceModelInformationSubSlotIndex } ::= { ruijieSystemDeviceModelInformationTable 1 } RuijieSystemDeviceModelInformationEntry ::= SEQUENCE { ruijieSystemDeviceModelInformationDeviceIndex Integer32, ruijieSystemDeviceModelInformationSlotIndex Integer32, ruijieSystemDeviceModelInformationSubSlotIndex Integer32, ruijieSystemDeviceModelInformationCPUName DisplayString, ruijieSystemDeviceModelInformationMACName DisplayString, ruijieSystemDeviceModelInformationFabricName DisplayString, ruijieSystemDeviceModelInformationSDRAMName DisplayString, ruijieSystemDeviceModelInformationFlashName DisplayString, ruijieSystemDeviceModelInformationPHYName DisplayString, ruijieSystemDeviceModelInformationClockName DisplayString, ruijieSystemDeviceModelInformationDCDCName DisplayString } ruijieSystemDeviceModelInformationDeviceIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device." ::= { ruijieSystemDeviceModelInformationEntry 1 } ruijieSystemDeviceModelInformationSlotIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a slot device." ::= { ruijieSystemDeviceModelInformationEntry 2 } ruijieSystemDeviceModelInformationSubSlotIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a sub slot device." ::= { ruijieSystemDeviceModelInformationEntry 3 } ruijieSystemDeviceModelInformationCPUName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the CPU." ::= { ruijieSystemDeviceModelInformationEntry 4 } ruijieSystemDeviceModelInformationMACName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the MAC." ::= { ruijieSystemDeviceModelInformationEntry 5 } ruijieSystemDeviceModelInformationFabricName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the fabric." ::= { ruijieSystemDeviceModelInformationEntry 6 } ruijieSystemDeviceModelInformationSDRAMName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the SDRAM." ::= { ruijieSystemDeviceModelInformationEntry 7 } ruijieSystemDeviceModelInformationFlashName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the Flash." ::= { ruijieSystemDeviceModelInformationEntry 8 } ruijieSystemDeviceModelInformationPHYName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the PHY." ::= { ruijieSystemDeviceModelInformationEntry 9 } ruijieSystemDeviceModelInformationClockName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the clock." ::= { ruijieSystemDeviceModelInformationEntry 10 } ruijieSystemDeviceModelInformationDCDCName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Returns the model name of the DC-DC." ::= { ruijieSystemDeviceModelInformationEntry 11 } ruijieSystemAllTotalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The output power of the all devices. (Unit W)" ::= { ruijieSystemMIBObjects 79 } ruijieSystemDeviceInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF RuijieSystemDeviceInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of device information entries. Each object displays the devcie's information." ::= { ruijieSystemMIBObjects 80 } ruijieSystemDeviceInformationEntry OBJECT-TYPE SYNTAX RuijieSystemDeviceInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry displays the device's information." INDEX { ruijieSystemDeviceInformationIndex } ::= { ruijieSystemDeviceInformationTable 1 } RuijieSystemDeviceInformationEntry ::= SEQUENCE { ruijieSystemDeviceInformationIndex Integer32, ruijieSystemDeviceInformationName DisplayString, ruijieSystemDeviceInformationOutPower Integer32 } ruijieSystemDeviceInformationIndex OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely represents a device's information." ::= { ruijieSystemDeviceInformationEntry 1 } ruijieSystemDeviceInformationName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual name assigned to a device" ::= { ruijieSystemDeviceInformationEntry 2 } ruijieSystemDeviceInformationOutPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Return the current device's outpower of the FastSwitch.The device display is not supported for the current outpower returns to 0." ::= { ruijieSystemDeviceInformationEntry 3 } ruijieSystemMIBTraps OBJECT IDENTIFIER ::= { ruijieSystemMIB 2 } ruijieSystemHardChangeDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The description of hard change" ::= { ruijieSystemMIBTraps 1 } ruijieSystemHardChangeDetected NOTIFICATION-TYPE OBJECTS {ruijieSystemHardChangeDesc} STATUS current DESCRIPTION "System hardware has changed include number of devices or number of modules or the place or type of the module is change." ::= { ruijieSystemMIBTraps 2 } ruijieSystemPowerStateChange NOTIFICATION-TYPE OBJECTS {ruijieSystemHwPower} STATUS current DESCRIPTION "while the state of power changed, then this trap will be sent." ::= { ruijieSystemMIBTraps 3 } ruijieSystemFanStateChange NOTIFICATION-TYPE OBJECTS {ruijieSystemHwFan} STATUS current DESCRIPTION "while the state of fan changed, then this trap will be sent." ::= { ruijieSystemMIBTraps 4 } --2010-05 ruijieSystemCPUusageTooHighTrap NOTIFICATION-TYPE OBJECTS {ruijieCPUUtilization1Min} STATUS current DESCRIPTION "CPU usage Too High warning." ::= { ruijieSystemMIBTraps 5 } --2010-05 ruijieSystemCPUusageTooHighRecovTrap NOTIFICATION-TYPE OBJECTS {ruijieCPUUtilization1Min} STATUS current DESCRIPTION "clear the warning of CPU usage too high and report the current CPU usage." ::= { ruijieSystemMIBTraps 6 } --2010-05 ruijieSystemTmpTooHighTrap NOTIFICATION-TYPE OBJECTS {ruijieSystemTemperatureCurrent} STATUS current DESCRIPTION "Temperature Too High warning." ::= { ruijieSystemMIBTraps 7 } --Temperature Too High Recover Trap 2010-05 ruijieSystemTmpTooHighRecovTrap NOTIFICATION-TYPE OBJECTS {ruijieSystemTemperatureCurrent} STATUS current DESCRIPTION "clear the warning of temperature too high and report the current temperature." ::= { ruijieSystemMIBTraps 8 } --Memory usage too high trap 2010-05 ruijieSystemMemusageTooHighTrap NOTIFICATION-TYPE OBJECTS {ruijieMemoryPoolCurrentUtilization} STATUS current DESCRIPTION "Memory usage too high warning." ::= { ruijieSystemMIBTraps 9 } --Memory usage too high recover trap 2010-05 ruijieSystemMemusageTooHighRecovTrap NOTIFICATION-TYPE OBJECTS {ruijieMemoryPoolCurrentUtilization} STATUS current DESCRIPTION "clear the warning of Memory usage too high and report the current Memory usage." ::= { ruijieSystemMIBTraps 10 } --lank ap 2010-7 ruijieSystemLankApCPUusageTooHighTrap NOTIFICATION-TYPE OBJECTS { ruijieApMacAddr, ruijieCPUUtilization1Min } STATUS current DESCRIPTION "lank ap CPU usage Too High warning." ::= { ruijieSystemMIBTraps 11 } --lank ap 2010-7 ruijieSystemLankApCPUusageTooHighRecovTrap NOTIFICATION-TYPE OBJECTS { ruijieApMacAddr, ruijieCPUUtilization1Min } STATUS current DESCRIPTION "clear the warning of lank ap CPU usage too high and report the current CPU usage." ::= { ruijieSystemMIBTraps 12 } --lank ap 2010-7 ruijieSystemLankApMemusageTooHighTrap NOTIFICATION-TYPE OBJECTS { ruijieApMacAddr, ruijieMemoryPoolCurrentUtilization } STATUS current DESCRIPTION "lank ap Memory usage too high warning." ::= { ruijieSystemMIBTraps 13 } --lank ap 2010-7 ruijieSystemLankApMemusageTooHighRecovTrap NOTIFICATION-TYPE OBJECTS { ruijieApMacAddr, ruijieMemoryPoolCurrentUtilization } STATUS current DESCRIPTION "clear the warning of lank ap Memory usage too high and report the current Memory usage." ::= { ruijieSystemMIBTraps 14 } --System reset trap 2010-7 ruijieSystemResetTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "send a trap while system reset" ::= { ruijieSystemMIBTraps 15 } --lank ap reset trap 2010-8 ruijieSystemLankApResetTrap NOTIFICATION-TYPE OBJECTS {ruijieApMacAddr} STATUS current DESCRIPTION "send a trap while lank ap system reset" ::= { ruijieSystemMIBTraps 16 } ruijieSystemPowerOnTrap NOTIFICATION-TYPE OBJECTS {ruijieSystemPowerIndex} STATUS current DESCRIPTION "send a trap while power on." ::= { ruijieSystemMIBTraps 17 } ruijieSystemPowerOffTrap NOTIFICATION-TYPE OBJECTS {ruijieSystemPowerIndex} STATUS current DESCRIPTION "send a trap while power off." ::= { ruijieSystemMIBTraps 18 } ruijieSystemPowerOnTrapInVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID, ruijieSystemPowerIndex } STATUS current DESCRIPTION "send a trap while power on in VSU." ::= { ruijieSystemMIBTraps 19 } ruijieSystemPowerOffTrapInVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID, ruijieSystemPowerIndex } STATUS current DESCRIPTION "send a trap while power off in VSU." ::= { ruijieSystemMIBTraps 20 } ruijieSystemTmpTableTooHighTrap NOTIFICATION-TYPE OBJECTS { ruijieSystemMultipleTemperatureSlotIndex } STATUS current DESCRIPTION "Temperature Too High warning with the slot index." ::= { ruijieSystemMIBTraps 21 } ruijieSystemTmpTableTooHighRecovTrap NOTIFICATION-TYPE OBJECTS { ruijieSystemMultipleTemperatureSlotIndex } STATUS current DESCRIPTION "clear the warning of Temperature too high with the slot index." ::= { ruijieSystemMIBTraps 22 } ruijieSystemTmpTableTooHighTrapVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemMultipleTemperatureDeviceIndex, ruijieSystemMultipleTemperatureSlotIndex } STATUS current DESCRIPTION "Temperature Too High warning with the slot index in VSU." ::= { ruijieSystemMIBTraps 23 } ruijieSystemTmpTableTooHighRecovTrapVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemMultipleTemperatureDeviceIndex, ruijieSystemMultipleTemperatureSlotIndex } STATUS current DESCRIPTION "clear the warning of Temperature too high with the slot index." ::= { ruijieSystemMIBTraps 24 } ruijieSystemFanTableStateChange NOTIFICATION-TYPE OBJECTS { ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex, ruijieSystemFanStatus } STATUS current DESCRIPTION "while the state of fan changed, then this trap will be sent." ::= { ruijieSystemMIBTraps 25 } ruijieSystemFanTableStateChangeVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemFanStatusDeviceIndex, ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex, ruijieSystemFanStatus } STATUS current DESCRIPTION "In VSU, while the state of fan changed, then this trap will be sent." ::= { ruijieSystemMIBTraps 26 } ruijieSystemParamSaveErr NOTIFICATION-TYPE OBJECTS { ruijieSystemParamSaveErrIdx, ruijieSystemParamSaveErrMsg } STATUS current DESCRIPTION "while call exec write, then this trap will be sent." ::= { ruijieSystemMIBTraps 27 } ruijieSystemFanTableOn NOTIFICATION-TYPE OBJECTS { ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex, ruijieSystemFanStatus } STATUS current DESCRIPTION "while fan is turned on, then this trap will be sent." ::= { ruijieSystemMIBTraps 28 } ruijieSystemFanTableOff NOTIFICATION-TYPE OBJECTS { ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex, ruijieSystemFanStatus } STATUS current DESCRIPTION "while fan is turned off, then this trap will be sent." ::= { ruijieSystemMIBTraps 29 } ruijieSystemFanTableOnVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemFanStatusDeviceIndex, ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex, ruijieSystemFanStatus } STATUS current DESCRIPTION "In VSU, while fan is turned on, then this trap will be sent." ::= { ruijieSystemMIBTraps 30 } ruijieSystemFanTableOffVSU NOTIFICATION-TYPE OBJECTS { ruijieSystemFanStatusDeviceIndex, ruijieSystemFanStatusFanIndex, ruijieSystemFanStatusIndex, ruijieSystemFanStatus } STATUS current DESCRIPTION "In VSU, while fan is turned off, then this trap will be sent." ::= { ruijieSystemMIBTraps 31 } ruijieSwitchOverNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID } STATUS current DESCRIPTION " while redundancy forceswitch, then this trap will be sent." ::= { ruijieSystemMIBTraps 32 } ruijieResetNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID, entPhysicalName } STATUS current DESCRIPTION " while reset slot, then this trap will be sent." ::= { ruijieSystemMIBTraps 33 } ruijieOfflineNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID, entPhysicalName } STATUS current DESCRIPTION " while offline slot, then this trap will be sent." ::= { ruijieSystemMIBTraps 34 } ruijieSystemPowerOnNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID, entPhysicalName } STATUS current DESCRIPTION " while user enter power on command, then this trap will be sent." ::= { ruijieSystemMIBTraps 35 } ruijieSystemPowerOffNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID, entPhysicalName } STATUS current DESCRIPTION " while user enter power off command, then this trap will be sent." ::= { ruijieSystemMIBTraps 36 } --Memory usage too high trap 2019-03 ruijieSystemMemusageTooHighAlarm NOTIFICATION-TYPE OBJECTS { ruijieNodeMemoryPoolName, ruijieNodeMemoryPoolCurrentUtilization } STATUS current DESCRIPTION "Memory usage too high warning." ::= { ruijieSystemMIBTraps 37 } --Memory usage too high recover trap 2019-03 ruijieSystemMemusageTooHighRecovAlarm NOTIFICATION-TYPE OBJECTS { ruijieNodeMemoryPoolName, ruijieNodeMemoryPoolCurrentUtilization } STATUS current DESCRIPTION "Clear the warning of memory usage too high and report the current memory usage." ::= { ruijieSystemMIBTraps 38 } --CPUsage too high trap 2019-03 ruijieSystemCPUusageTooHighAlarm NOTIFICATION-TYPE OBJECTS { ruijieNodeCPUTotalName, ruijieNodeCPUTotal1min } STATUS current DESCRIPTION "CPU usage too high warning." ::= { ruijieSystemMIBTraps 39 } --CPUsage too high recover trap 2019-03 ruijieSystemCPUusageTooHighRecovAlarm NOTIFICATION-TYPE OBJECTS { ruijieNodeCPUTotalName, ruijieNodeCPUTotal1min } STATUS current DESCRIPTION "Clear the warning of CPU usage too high and report the current CPU usage." ::= { ruijieSystemMIBTraps 40 } ruijieSystemDeviceModeChange NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceMode } STATUS current DESCRIPTION "Notification of device running mode changing. Only support in all-in-one device." ::= { ruijieSystemMIBTraps 41 } ruijieSystemDeviceTemperatureWarningAlarm NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } STATUS current DESCRIPTION "Notification of device temperature reaches warning level." ::= { ruijieSystemMIBTraps 42 } ruijieSystemDeviceTemperatureWarningRecovAlarm NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } STATUS current DESCRIPTION "Clear the notification of device temperature reaches warning level." ::= { ruijieSystemMIBTraps 43 } ruijieSystemDeviceTemperatureCriticalAlarm NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } STATUS current DESCRIPTION "Notification of device temperature reaches critical level." ::= { ruijieSystemMIBTraps 44 } ruijieSystemDeviceTemperatureCriticalRecovAlarm NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } STATUS current DESCRIPTION "Clear the notification of device temperature reaches critical level." ::= { ruijieSystemMIBTraps 45 } ruijieSystemDeviceTemperatureShutdownAlarm NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } STATUS current DESCRIPTION "Notification of device temperature reaches shutdown level." ::= { ruijieSystemMIBTraps 46 } ruijieSystemDeviceTemperatureShutdownRecovAlarm NOTIFICATION-TYPE OBJECTS { ruijieSystemDeviceTemperatureDeviceIndex, ruijieSystemDeviceTemperatureSlotIndex, ruijieSystemDeviceTemperatureSubSlotIndex } STATUS current DESCRIPTION "Clear the notification of device temperature reaches shutdown level." ::= { ruijieSystemMIBTraps 47 } ruijieSwitchOverFailNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID } STATUS current DESCRIPTION "When redundancy forceswitch failed, this trap will be sent." ::= { ruijieSystemMIBTraps 48 } ruijieMasterSwitchoverPreviousMaster OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Previous master for ruijieMasterSwitchoverNotify." ::= { ruijieSystemMIBTraps 49 } ruijieMasterSwitchoverCurrentMaster OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Current master for ruijieMasterSwitchoverNotify." ::= { ruijieSystemMIBTraps 50 } ruijieMasterSwitchoverNotify NOTIFICATION-TYPE OBJECTS { ruijieMasterSwitchoverPreviousMaster, ruijieMasterSwitchoverCurrentMaster } STATUS current DESCRIPTION " When master changed, this trap will be sent." ::= { ruijieSystemMIBTraps 51 } ruijieSystemFanRemovedTimeoutNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID } STATUS current DESCRIPTION "When a fan is absent for 2 minutes, this trap will be sent." ::= { ruijieSystemMIBTraps 52 } ruijieSystemFanRemovedResumeNotify NOTIFICATION-TYPE OBJECTS { ruijieSystemSwitchID } STATUS current DESCRIPTION "When no fan is absent for 2 minutes, this trap will be sent." ::= { ruijieSystemMIBTraps 53 } ruijieCardPowerOnNotify NOTIFICATION-TYPE OBJECTS { entPhysicalName } STATUS current DESCRIPTION "When user enter power on command, this trap will be sent." ::= { ruijieSystemMIBTraps 54 } ruijieCardPowerOffNotify NOTIFICATION-TYPE OBJECTS { entPhysicalName } STATUS current DESCRIPTION "When user enter power off command, this trap will be sent." ::= { ruijieSystemMIBTraps 55 } ruijieSystemVacConfigDiff NOTIFICATION-TYPE OBJECTS { ruijieSystemVacConfigDiffMsg } STATUS current DESCRIPTION "while the running config of slave vac is different to master vac, then this trap will be sent." ::= { ruijieSystemMIBTraps 56 } ruijieSystemMIBConformance OBJECT IDENTIFIER ::= { ruijieSystemMIB 3 } ruijieSystemMIBCompliances OBJECT IDENTIFIER ::= { ruijieSystemMIBConformance 1 } ruijieSystemMIBGroups OBJECT IDENTIFIER ::= { ruijieSystemMIBConformance 2 } -- compliance statements ruijieSystemMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Ruijie System MIB" MODULE -- this module MANDATORY-GROUPS { ruijieSystemMIBGroup } ::= { ruijieSystemMIBCompliances 1 } -- units of conformance ruijieSystemMIBGroup OBJECT-GROUP OBJECTS { ruijieSystemHwVersion, ruijieSystemSwVersion, ruijieSystemBootVersion, ruijieSystemSysCtrlVersion, ruijieSystemParametersSave, ruijieSystemReset, ruijieSystemOutBandRate, ruijieSwitchLayer } STATUS current DESCRIPTION "A collection of objects providing system information and opertion to a Ruijie agent." ::= { ruijieSystemMIBGroups 1 } END