TERACOM-TCW210-TH-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, IpAddress, Integer32, snmpModules FROM SNMPv2-SMI DateAndTime, MacAddress, DisplayString FROM SNMPv2-TC TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP , NOTIFICATION-GROUP FROM SNMPv2-CONF; snmpMIB MODULE-IDENTITY LAST-UPDATED "202104160000Z" ORGANIZATION "TERACOM" CONTACT-INFO "EMail: info@teracomsystems.com" DESCRIPTION "The MIB module for TCW210-TH SNMP entities." REVISION "202104160000Z" DESCRIPTION "TCW210-THv1.2" ::= { snmpModules 1 } teracom OBJECT IDENTIFIER ::= { enterprises 38783 } tcw210th OBJECT IDENTIFIER ::= { teracom 4 } trapNotifications OBJECT IDENTIFIER ::= { tcw210th 0 } product OBJECT IDENTIFIER ::= { tcw210th 1 } setup OBJECT IDENTIFIER ::= { tcw210th 2 } monitorNcontrol OBJECT IDENTIFIER ::= { tcw210th 3 } tcw210thMIBConformance OBJECT IDENTIFIER ::= { tcw210th 4 } tcw210thMIBCompliances OBJECT IDENTIFIER ::= { tcw210thMIBConformance 1 } tcw210thMIBGroups OBJECT IDENTIFIER ::= { tcw210thMIBConformance 2 } SensorId ::= TEXTUAL-CONVENTION DISPLAY-HINT "16a" STATUS current DESCRIPTION "Sensor ROM code in ASCII HEX format" SYNTAX OCTET STRING (SIZE (16)) SensorValue ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-3" STATUS current DESCRIPTION "Sensor value x1000 in Integer format" SYNTAX Integer32 ALARMSTATUS ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Alarm status" SYNTAX INTEGER {normal(0),alarm(1)} name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of product" ::= { product 1 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version string" ::= { product 2 } dateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time" ::= { product 3 } network OBJECT IDENTIFIER ::= { setup 1 } deviceID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Device ID is Default MAC Address" ::= { network 1 } hostName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..38)) MAX-ACCESS read-only STATUS current DESCRIPTION "Host Name" ::= { network 2 } deviceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Device IP Address" ::= { network 3 } io OBJECT IDENTIFIER ::= { setup 2 } sensorsSetup OBJECT IDENTIFIER ::= { io 1 } sensor1setup OBJECT IDENTIFIER ::= { sensorsSetup 1 } sensor2setup OBJECT IDENTIFIER ::= { sensorsSetup 2 } sensor3setup OBJECT IDENTIFIER ::= { sensorsSetup 3 } sensor4setup OBJECT IDENTIFIER ::= { sensorsSetup 4 } sensor5setup OBJECT IDENTIFIER ::= { sensorsSetup 5 } sensor6setup OBJECT IDENTIFIER ::= { sensorsSetup 6 } sensor7setup OBJECT IDENTIFIER ::= { sensorsSetup 7 } sensor8setup OBJECT IDENTIFIER ::= { sensorsSetup 8 } s1description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sensor1 description" ::= { sensor1setup 1 } sensor11setup OBJECT IDENTIFIER ::= { sensor1setup 2 } sensor12setup OBJECT IDENTIFIER ::= { sensor1setup 3 } sensor13setup OBJECT IDENTIFIER ::= { sensor1setup 4 } s11MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S11 maximum value x1000 in Integer format" ::= { sensor11setup 1 } s11MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S11 minimum value x1000 in Integer format" ::= { sensor11setup 2 } s11HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S11 hysteresis value x1000 in Integer format" ::= { sensor11setup 3 } s11MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S11 multiplier value x1000 in Integer format" ::= { sensor11setup 4 } s11OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S11 offset value x1000 in Integer format" ::= { sensor11setup 5 } s12MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S12 maximum value x1000 in Integer format" ::= { sensor12setup 1 } s12MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S12 minimum value x1000 in Integer format" ::= { sensor12setup 2 } s12HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S12 hysteresis value x1000 in Integer format" ::= { sensor12setup 3 } s12MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S12 multiplier value x1000 in Integer format" ::= { sensor12setup 4 } s12OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S12 offset value x1000 in Integer format" ::= { sensor12setup 5 } s13MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S13 maximum value x1000 in Integer format" ::= { sensor13setup 1 } s13MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S13 minimum value x1000 in Integer format" ::= { sensor13setup 2 } s13HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S13 hysteresis value x1000 in Integer format" ::= { sensor13setup 3 } s2description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor2 description" ::= { sensor2setup 1 } sensor21setup OBJECT IDENTIFIER ::= { sensor2setup 2 } sensor22setup OBJECT IDENTIFIER ::= { sensor2setup 3 } sensor23setup OBJECT IDENTIFIER ::= { sensor2setup 4 } s21MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s21 maximum value x1000 in Integer format" ::= { sensor21setup 1 } s21MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s21 minimum value x1000 in Integer format" ::= { sensor21setup 2 } s21HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s21 hysteresis value x1000 in Integer format" ::= { sensor21setup 3 } s21MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S21 multiplier value x1000 in Integer format" ::= { sensor21setup 4 } s21OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S21 offset value x1000 in Integer format" ::= { sensor21setup 5 } s22MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s22 maximum value x1000 in Integer format" ::= { sensor22setup 1 } s22MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s22 minimum value x1000 in Integer format" ::= { sensor22setup 2 } s22HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s22 hysteresis value x1000 in Integer format" ::= { sensor22setup 3 } s22MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S22 multiplier value x1000 in Integer format" ::= { sensor22setup 4 } s22OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S22 offset value x1000 in Integer format" ::= { sensor22setup 5 } s23MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S23 maximum value x1000 in Integer format" ::= { sensor23setup 1 } s23MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S23 minimum value x1000 in Integer format" ::= { sensor23setup 2 } s23HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S23 hysteresis value x1000 in Integer format" ::= { sensor23setup 3 } s3description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor3 description" ::= { sensor3setup 1 } sensor31setup OBJECT IDENTIFIER ::= { sensor3setup 2 } sensor32setup OBJECT IDENTIFIER ::= { sensor3setup 3 } sensor33setup OBJECT IDENTIFIER ::= { sensor3setup 4 } s31MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s31 maximum value x1000 in Integer format" ::= { sensor31setup 1 } s31MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s31 minimum value x1000 in Integer format" ::= { sensor31setup 2 } s31HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s31 hysteresis value x1000 in Integer format" ::= { sensor31setup 3 } s31MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S31 multiplier value x1000 in Integer format" ::= { sensor31setup 4 } s31OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S31 offset value x1000 in Integer format" ::= { sensor31setup 5 } s32MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s32 maximum value x1000 in Integer format" ::= { sensor32setup 1 } s32MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s32 minimum value x1000 in Integer format" ::= { sensor32setup 2 } s32HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s32 hysteresis value x1000 in Integer format" ::= { sensor32setup 3 } s32MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S32 multiplier value x1000 in Integer format" ::= { sensor32setup 4 } s32OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S32 offset value x1000 in Integer format" ::= { sensor32setup 5 } s33MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s33 maximum value x1000 in Integer format" ::= { sensor33setup 1 } s33MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s33 minimum value x1000 in Integer format" ::= { sensor33setup 2 } s33HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s33 hysteresis value x1000 in Integer format" ::= { sensor33setup 3 } s4description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor4 description" ::= { sensor4setup 1 } sensor41setup OBJECT IDENTIFIER ::= { sensor4setup 2 } sensor42setup OBJECT IDENTIFIER ::= { sensor4setup 3 } sensor43setup OBJECT IDENTIFIER ::= { sensor4setup 4 } s41MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s41 maximum value x1000 in Integer format" ::= { sensor41setup 1 } s41MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s41 minimum value x1000 in Integer format" ::= { sensor41setup 2 } s41HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s41 hysteresis value x1000 in Integer format" ::= { sensor41setup 3 } s41MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S41 multiplier value x1000 in Integer format" ::= { sensor41setup 4 } s41OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S41 offset value x1000 in Integer format" ::= { sensor41setup 5 } s42MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s42 maximum value x1000 in Integer format" ::= { sensor42setup 1 } s42MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s42 minimum value x1000 in Integer format" ::= { sensor42setup 2 } s42HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s42 hysteresis value x1000 in Integer format" ::= { sensor42setup 3 } s42MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S42 multiplier value x1000 in Integer format" ::= { sensor42setup 4 } s42OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S42 offset value x1000 in Integer format" ::= { sensor42setup 5 } s43MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s43 maximum value x1000 in Integer format" ::= { sensor43setup 1 } s43MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s43 minimum value x1000 in Integer format" ::= { sensor43setup 2 } s43HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s43 hysteresis value x1000 in Integer format" ::= { sensor43setup 3 } s5description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor5 description" ::= { sensor5setup 1 } sensor51setup OBJECT IDENTIFIER ::= { sensor5setup 2 } sensor52setup OBJECT IDENTIFIER ::= { sensor5setup 3 } sensor53setup OBJECT IDENTIFIER ::= { sensor5setup 4 } s51MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s51 maximum value x1000 in Integer format" ::= { sensor51setup 1 } s51MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s51 minimum value x1000 in Integer format" ::= { sensor51setup 2 } s51HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s51 hysteresis value x1000 in Integer format" ::= { sensor51setup 3 } s51MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S51 multiplier value x1000 in Integer format" ::= { sensor51setup 4 } s51OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S51 offset value x1000 in Integer format" ::= { sensor51setup 5 } s52MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s52 maximum value x1000 in Integer format" ::= { sensor52setup 1 } s52MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s52 minimum value x1000 in Integer format" ::= { sensor52setup 2 } s52HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s52 hysteresis value x1000 in Integer format" ::= { sensor52setup 3 } s52MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S52 multiplier value x1000 in Integer format" ::= { sensor52setup 4 } s52OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S52 offset value x1000 in Integer format" ::= { sensor52setup 5 } s53MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s53 maximum value x1000 in Integer format" ::= { sensor53setup 1 } s53MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s53 minimum value x1000 in Integer format" ::= { sensor53setup 2 } s53HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s53 hysteresis value x1000 in Integer format" ::= { sensor53setup 3 } s6description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor6 description" ::= { sensor6setup 1 } sensor61setup OBJECT IDENTIFIER ::= { sensor6setup 2 } sensor62setup OBJECT IDENTIFIER ::= { sensor6setup 3 } sensor63setup OBJECT IDENTIFIER ::= { sensor6setup 4 } s61MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s61 maximum value x1000 in Integer format" ::= { sensor61setup 1 } s61MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s61 minimum value x1000 in Integer format" ::= { sensor61setup 2 } s61HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s61 hysteresis value x1000 in Integer format" ::= { sensor61setup 3 } s61MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S61 multiplier value x1000 in Integer format" ::= { sensor61setup 4 } s61OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S61 offset value x1000 in Integer format" ::= { sensor61setup 5 } s62MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s62 maximum value x1000 in Integer format" ::= { sensor62setup 1 } s62MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s62 minimum value x1000 in Integer format" ::= { sensor62setup 2 } s62HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s62 hysteresis value x1000 in Integer format" ::= { sensor62setup 3 } s62MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S62 multiplier value x1000 in Integer format" ::= { sensor62setup 4 } s62OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S62 offset value x1000 in Integer format" ::= { sensor62setup 5 } s63MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s63 maximum value x1000 in Integer format" ::= { sensor63setup 1 } s63MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s63 minimum value x1000 in Integer format" ::= { sensor63setup 2 } s63HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s63 hysteresis value x1000 in Integer format" ::= { sensor63setup 3 } s7description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor7 description" ::= { sensor7setup 1 } sensor71setup OBJECT IDENTIFIER ::= { sensor7setup 2 } sensor72setup OBJECT IDENTIFIER ::= { sensor7setup 3 } sensor73setup OBJECT IDENTIFIER ::= { sensor7setup 4 } s71MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s71 maximum value x1000 in Integer format" ::= { sensor71setup 1 } s71MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s71 minimum value x1000 in Integer format" ::= { sensor71setup 2 } s71HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s71 hysteresis value x1000 in Integer format" ::= { sensor71setup 3 } s71MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S71 multiplier value x1000 in Integer format" ::= { sensor71setup 4 } s71OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S71 offset value x1000 in Integer format" ::= { sensor71setup 5 } s72MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s72 maximum value x1000 in Integer format" ::= { sensor72setup 1 } s72MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s72 minimum value x1000 in Integer format" ::= { sensor72setup 2 } s72HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s72 hysteresis value x1000 in Integer format" ::= { sensor72setup 3 } s72MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S72 multiplier value x1000 in Integer format" ::= { sensor72setup 4 } s72OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S72 offset value x1000 in Integer format" ::= { sensor72setup 5 } s73MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s73 maximum value x1000 in Integer format" ::= { sensor73setup 1 } s73MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s73 minimum value x1000 in Integer format" ::= { sensor73setup 2 } s73HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s73 hysteresis value x1000 in Integer format" ::= { sensor73setup 3 } s8description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor8 description" ::= { sensor8setup 1 } sensor81setup OBJECT IDENTIFIER ::= { sensor8setup 2 } sensor82setup OBJECT IDENTIFIER ::= { sensor8setup 3 } sensor83setup OBJECT IDENTIFIER ::= { sensor8setup 4 } s81MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s81 maximum value x1000 in Integer format" ::= { sensor81setup 1 } s81MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s81 minimum value x1000 in Integer format" ::= { sensor81setup 2 } s81HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s81 hysteresis value x1000 in Integer format" ::= { sensor81setup 3 } s81MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S81 multiplier value x1000 in Integer format" ::= { sensor81setup 4 } s81OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S81 offset value x1000 in Integer format" ::= { sensor81setup 5 } s82MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s82 maximum value x1000 in Integer format" ::= { sensor82setup 1 } s82MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s82 minimum value x1000 in Integer format" ::= { sensor82setup 2 } s82HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s82 hysteresis value x1000 in Integer format" ::= { sensor82setup 3 } s82MULTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S82 multiplier value x1000 in Integer format" ::= { sensor82setup 4 } s82OFFSETInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "S82 offset value x1000 in Integer format" ::= { sensor82setup 5 } s83MAXInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s83 maximum value x1000 in Integer format" ::= { sensor83setup 1 } s83MINInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s83 minimum value x1000 in Integer format" ::= { sensor83setup 2 } s83HYSTInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-write STATUS current DESCRIPTION "s83 hysteresis value x1000 in Integer format" ::= { sensor83setup 3 } sensors OBJECT IDENTIFIER ::= { monitorNcontrol 1 } sensor1 OBJECT IDENTIFIER ::= { sensors 1 } s1Alarm OBJECT IDENTIFIER ::= { sensor1 5 } s11Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S11 value x1000 in Integer format" ::= { sensor1 1 } s12Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S12 value x1000 in Integer format" ::= { sensor1 2 } s13Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S13 dew point value x1000 in Integer format" ::= { sensor1 3 } s1ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S1 ID value" ::= { sensor1 4 } s11Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S11 alarm status" ::= { s1Alarm 1 } s12Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S12 alarm status" ::= { s1Alarm 2 } s13Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S13 alarm status" ::= { s1Alarm 3 } s11RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S11 raw value x1000 in Integer format" ::= { sensor1 6 } s12RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S12 raw value x1000 in Integer format" ::= { sensor1 7 } sensor2 OBJECT IDENTIFIER ::= { sensors 2 } s2Alarm OBJECT IDENTIFIER ::= { sensor2 5 } s21Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S21 value x1000 in Integer format" ::= { sensor2 1 } s22Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S22 value x1000 in Integer format" ::= { sensor2 2 } s23Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S23 dew point value x1000 in Integer format" ::= { sensor2 3 } s2ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S2 ID value" ::= { sensor2 4 } s21Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S21 alarm status" ::= { s2Alarm 1 } s22Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S22 alarm status" ::= { s2Alarm 2 } s23Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S23 alarm status" ::= { s2Alarm 3 } s21RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S21 raw value x1000 in Integer format" ::= { sensor2 6 } s22RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S22 raw value x1000 in Integer format" ::= { sensor2 7 } sensor3 OBJECT IDENTIFIER ::= { sensors 3 } s3Alarm OBJECT IDENTIFIER ::= { sensor3 5 } s31Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S31 value x1000 in Integer format" ::= { sensor3 1 } s32Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S32 value x1000 in Integer format" ::= { sensor3 2 } s33Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S33 dew point value x1000 in Integer format" ::= { sensor3 3 } s3ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S3 ID value" ::= { sensor3 4 } s31Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S31 alarm status" ::= { s3Alarm 1 } s32Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S32 alarm status" ::= { s3Alarm 2 } s33Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S33 alarm status" ::= { s3Alarm 3 } s31RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S31 raw value x1000 in Integer format" ::= { sensor3 6 } s32RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S32 raw value x1000 in Integer format" ::= { sensor3 7 } sensor4 OBJECT IDENTIFIER ::= { sensors 4 } s4Alarm OBJECT IDENTIFIER ::= { sensor4 5 } s41Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S41 value x1000 in Integer format" ::= { sensor4 1 } s42Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S42 value x1000 in Integer format" ::= { sensor4 2 } s43Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S43 dew point value x1000 in Integer format" ::= { sensor4 3 } s4ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S4 ID value" ::= { sensor4 4 } s41Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S41 alarm status" ::= { s4Alarm 1 } s42Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S42 alarm status" ::= { s4Alarm 2 } s43Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S43 alarm status" ::= { s4Alarm 3 } s41RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S41 raw value x1000 in Integer format" ::= { sensor4 6 } s42RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S42 raw value x1000 in Integer format" ::= { sensor4 7 } sensor5 OBJECT IDENTIFIER ::= { sensors 5 } s5Alarm OBJECT IDENTIFIER ::= { sensor5 5 } s51Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S51 value x1000 in Integer format" ::= { sensor5 1 } s52Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S52 value x1000 in Integer format" ::= { sensor5 2 } s53Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S53 dew point value x1000 in Integer format" ::= { sensor5 3 } s5ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S5 ID value" ::= { sensor5 4 } s51Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S51 alarm status" ::= { s5Alarm 1 } s52Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S52 alarm status" ::= { s5Alarm 2 } s53Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S53 alarm status" ::= { s5Alarm 3 } s51RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S51 raw value x1000 in Integer format" ::= { sensor5 6 } s52RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S52 raw value x1000 in Integer format" ::= { sensor5 7 } sensor6 OBJECT IDENTIFIER ::= { sensors 6 } s6Alarm OBJECT IDENTIFIER ::= { sensor6 5 } s61Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S61 value x1000 in Integer format" ::= { sensor6 1 } s62Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S62 value x1000 in Integer format" ::= { sensor6 2 } s63Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S63 dew point value x1000 in Integer format" ::= { sensor6 3 } s6ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S6 ID value" ::= { sensor6 4 } s61Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S61 alarm status" ::= { s6Alarm 1 } s62Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S62 alarm status" ::= { s6Alarm 2 } s63Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S63 alarm status" ::= { s6Alarm 3 } s61RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S61 raw value x1000 in Integer format" ::= { sensor6 6 } s62RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S62 raw value x1000 in Integer format" ::= { sensor6 7 } sensor7 OBJECT IDENTIFIER ::= { sensors 7 } s7Alarm OBJECT IDENTIFIER ::= { sensor7 5 } s71Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S71 value x1000 in Integer format" ::= { sensor7 1 } s72Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S72 value x1000 in Integer format" ::= { sensor7 2 } s73Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S73 dew point value x1000 in Integer format" ::= { sensor7 3 } s7ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S7 ID value" ::= { sensor7 4 } s71Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S71 alarm status" ::= { s7Alarm 1 } s72Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S72 alarm status" ::= { s7Alarm 2 } s73Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S73 alarm status" ::= { s7Alarm 3 } s71RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S71 raw value x1000 in Integer format" ::= { sensor7 6 } s72RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S72 raw value x1000 in Integer format" ::= { sensor7 7 } sensor8 OBJECT IDENTIFIER ::= { sensors 8 } s8Alarm OBJECT IDENTIFIER ::= { sensor8 5 } s81Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S81 value x1000 in Integer format" ::= { sensor8 1 } s82Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S82 value x1000 in Integer format" ::= { sensor8 2 } s83Int OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S83 dew point value x1000 in Integer format" ::= { sensor8 3 } s8ID OBJECT-TYPE SYNTAX SensorId MAX-ACCESS read-only STATUS current DESCRIPTION "S8 ID value" ::= { sensor8 4 } s81Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S81 alarm status" ::= { s8Alarm 1 } s82Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S82 alarm status" ::= { s8Alarm 2 } s83Al OBJECT-TYPE SYNTAX ALARMSTATUS MAX-ACCESS read-only STATUS current DESCRIPTION "S83 alarm status" ::= { s8Alarm 3 } s81RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S81 raw value x1000 in Integer format" ::= { sensor8 6 } s82RawInt OBJECT-TYPE SYNTAX SensorValue MAX-ACCESS read-only STATUS current DESCRIPTION "S82 raw value x1000 in Integer format" ::= { sensor8 7 } --- configurationSaved configurationSaved OBJECT-TYPE SYNTAX INTEGER { unsaved(0), saved(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configuration save status SAVED/UNSAVED" ::= { monitorNcontrol 5 } restartDevice OBJECT-TYPE SYNTAX INTEGER { cancel(0), restart(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Restart Device" ::= { monitorNcontrol 6} temperatureUnit OBJECT-TYPE SYNTAX INTEGER { celcius(0), fahrenheit(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Unit of the all temperature values" ::= { monitorNcontrol 7} hardwareErr OBJECT-TYPE SYNTAX INTEGER { noErr(0), owErr(1), hwErr(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Error" ::= { monitorNcontrol 8} snmp-trap-notification NOTIFICATION-TYPE OBJECTS { s11Int,s12Int,s13Int,s11Al,s12Al,s13Al, s21Int,s22Int,s23Int,s21Al,s22Al,s23Al, s31Int,s32Int,s33Int,s31Al,s32Al,s33Al, s41Int,s42Int,s43Int,s41Al,s42Al,s43Al, s51Int,s52Int,s53Int,s51Al,s52Al,s53Al, s61Int,s62Int,s63Int,s61Al,s62Al,s63Al, s71Int,s72Int,s73Int,s71Al,s72Al,s73Al, s81Int,s82Int,s83Int,s81Al,s82Al,s83Al, restartDevice, deviceIP} STATUS current DESCRIPTION "SMIV2 Trap notification information for the SNMP Manager." ::= {trapNotifications 1} tcw210thMIBCompliances1 MODULE-COMPLIANCE STATUS current DESCRIPTION "This group is for SNMP applications." MODULE -- this module MANDATORY-GROUPS { tcw210thProductGroup, tcw210thSetupGroup, tcw210thMonitorGroup, tcw210thTrapGroup} ::= { tcw210thMIBCompliances 1 } tcw210thProductGroup OBJECT-GROUP OBJECTS {name, version, dateTime} STATUS current DESCRIPTION "A collection of objects providing basic product info." ::= { tcw210thMIBGroups 1 } tcw210thSetupGroup OBJECT-GROUP OBJECTS { deviceID, hostName, deviceIP, s1description, s11MAXInt, s11MINInt, s11HYSTInt, s11MULTInt, s11OFFSETInt, s12MAXInt, s12MINInt, s12HYSTInt, s12MULTInt, s12OFFSETInt, s13MAXInt, s13MINInt, s13HYSTInt, s2description, s21MAXInt, s21MINInt, s21HYSTInt, s21MULTInt, s21OFFSETInt, s22MAXInt, s22MINInt, s22HYSTInt, s22MULTInt, s22OFFSETInt, s23MAXInt, s23MINInt, s23HYSTInt, s3description, s31MAXInt, s31MINInt, s31HYSTInt, s31MULTInt, s31OFFSETInt, s32MAXInt, s32MINInt, s32HYSTInt, s32MULTInt, s32OFFSETInt, s33MAXInt, s33MINInt, s33HYSTInt, s4description, s41MAXInt, s41MINInt, s41HYSTInt, s41MULTInt, s41OFFSETInt, s42MAXInt, s42MINInt, s42HYSTInt, s42MULTInt, s42OFFSETInt, s43MAXInt, s43MINInt, s43HYSTInt, s5description, s51MAXInt, s51MINInt, s51HYSTInt, s51MULTInt, s51OFFSETInt, s52MAXInt, s52MINInt, s52HYSTInt, s52MULTInt, s52OFFSETInt, s53MAXInt, s53MINInt, s53HYSTInt, s6description, s61MAXInt, s61MINInt, s61HYSTInt, s61MULTInt, s61OFFSETInt, s62MAXInt, s62MINInt, s62HYSTInt, s62MULTInt, s62OFFSETInt, s63MAXInt, s63MINInt, s63HYSTInt, s7description, s71MAXInt, s71MINInt, s71HYSTInt, s71MULTInt, s71OFFSETInt, s72MAXInt, s72MINInt, s72HYSTInt, s72MULTInt, s72OFFSETInt, s73MAXInt, s73MINInt, s73HYSTInt, s8description, s81MAXInt, s81MINInt, s81HYSTInt, s81MULTInt, s81OFFSETInt, s82MAXInt, s82MINInt, s82HYSTInt, s82MULTInt, s82OFFSETInt, s83MAXInt, s83MINInt, s83HYSTInt } STATUS current DESCRIPTION "A collection of objects providing basic setup." ::= { tcw210thMIBGroups 2 } tcw210thMonitorGroup OBJECT-GROUP OBJECTS { s11Int, s12Int, s13Int, s1ID, s11Al, s12Al, s13Al, s11RawInt, s12RawInt, s21Int, s22Int, s23Int, s2ID, s21Al, s22Al, s23Al, s21RawInt, s22RawInt, s31Int, s32Int, s33Int, s3ID, s31Al, s32Al, s33Al, s31RawInt, s32RawInt, s41Int, s42Int, s43Int, s4ID, s41Al, s42Al, s43Al, s41RawInt, s42RawInt, s51Int, s52Int, s53Int, s5ID, s51Al, s52Al, s53Al, s51RawInt, s52RawInt, s61Int, s62Int, s63Int, s6ID, s61Al, s62Al, s63Al, s61RawInt, s62RawInt, s71Int, s72Int, s73Int, s7ID, s71Al, s72Al, s73Al, s71RawInt, s72RawInt, s81Int, s82Int, s83Int, s8ID, s81Al, s82Al, s83Al, s81RawInt, s82RawInt, configurationSaved, restartDevice, temperatureUnit, hardwareErr } STATUS current DESCRIPTION "A collection of objects providing basic monitoring and control of a product." ::= { tcw210thMIBGroups 3 } tcw210thTrapGroup NOTIFICATION-GROUP NOTIFICATIONS {snmp-trap-notification} STATUS current DESCRIPTION "SNMP Trap Notification object." ::= { tcw210thMIBGroups 4 } END