    "os": {
        "discovery": {
            "devices": [
                {
                    "sysName": "<private>",
                    "sysObjectID": ".1.3.6.1.4.1.11863.5.33",
                    "sysDescr": "JetStream 24-Port Gigabit L2 Managed Switch with 4 SFP Slots",
                    "sysContact": "<private>",
                    "version": "3.0.3 Build 20181101 Rel.42543(s)",
                    "hardware": "T2600G-28TS 3.0",
                    "features": null,
                    "location": "<private>",
                    "os": "jetstream",
                    "type": "network",
                    "serial": "217B851000014",
                    "icon": "tplink.svg"
                }
            ]
        },
        "poller": "matches discovery"
    },
    "mempools": {
        "discovery": {
            "mempools": [
                {
                    "mempool_index": "1",
                    "entPhysicalIndex": null,
                    "mempool_type": "jetstream",
                    "mempool_class": "system",
                    "mempool_precision": 1,
                    "mempool_descr": "Memory #1",
                    "mempool_perc": 68,
                    "mempool_perc_oid": ".1.3.6.1.4.1.11863.6.4.1.2.1.1.2.1",
                    "mempool_used": 68,
                    "mempool_used_oid": null,
                    "mempool_free": 32,
                    "mempool_free_oid": null,
                    "mempool_total": 100,
                    "mempool_total_oid": null,
                    "mempool_largestfree": null,
                    "mempool_lowestfree": null,
                    "mempool_deleted": 0,
                    "mempool_perc_warn": 90
                }
            ]
        },
        "poller": "matches discovery"
    },
    "processors": {
        "discovery": {
            "processors": [
                {
                    "entPhysicalIndex": 0,
                    "hrDeviceIndex": 0,
                    "processor_oid": ".1.3.6.1.4.1.11863.6.4.1.1.1.1.2.1",
                    "processor_index": "1",
                    "processor_type": "jetstream",
                    "processor_usage": 27,
                    "processor_descr": "Proc #1",
                    "processor_precision": 1,
                    "processor_perc_warn": 75
                }
            ]
        },
        "poller": "matches discovery"
    },
    "sensors": {
        "discovery": {
            "sensors": [
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49177",
                    "sensor_index": "ddmStatusBiasCurrent.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Bias Current 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.009568,
                    "sensor_limit": 0.015,
                    "sensor_limit_warn": 0.013,
                    "sensor_limit_low": 0.001,
                    "sensor_limit_low_warn": 0.002,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49178",
                    "sensor_index": "ddmStatusBiasCurrent.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Bias Current 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.009176,
                    "sensor_limit": 0.015,
                    "sensor_limit_warn": 0.013,
                    "sensor_limit_low": 0.001,
                    "sensor_limit_low_warn": 0.002,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49177",
                    "sensor_index": "ddmStatusRxPow.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM RX Power 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -5.9998036493484,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -28.538719643218,
                    "sensor_limit_low_warn": -26.98970004336,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49178",
                    "sensor_index": "ddmStatusRxPow.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM RX Power 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -5.9998036493484,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -28.538719643218,
                    "sensor_limit_low_warn": -26.98970004336,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49177",
                    "sensor_index": "ddmStatusTxPow.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM TX Power 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -4.0011692792631,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -11.999706407559,
                    "sensor_limit_low_warn": -11.001794975729,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49178",
                    "sensor_index": "ddmStatusTxPow.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM TX Power 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -3.9902710431325,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -11.999706407559,
                    "sensor_limit_low_warn": -11.001794975729,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49177",
                    "sensor_index": "49177",
                    "sensor_type": "ddmStatusDataReady",
                    "sensor_descr": "DDM Data Ready 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusDataReady"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49178",
                    "sensor_index": "49178",
                    "sensor_type": "ddmStatusDataReady",
                    "sensor_descr": "DDM Data Ready 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusDataReady"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49177",
                    "sensor_index": "49177",
                    "sensor_type": "ddmStatusLossSignal",
                    "sensor_descr": "DDM Loss of Signal 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusLossSignal"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49178",
                    "sensor_index": "49178",
                    "sensor_type": "ddmStatusLossSignal",
                    "sensor_descr": "DDM Loss of Signal 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusLossSignal"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49177",
                    "sensor_index": "49177",
                    "sensor_type": "ddmStatusTxFault",
                    "sensor_descr": "DDM TX Fault 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusTxFault"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49178",
                    "sensor_index": "49178",
                    "sensor_type": "ddmStatusTxFault",
                    "sensor_descr": "DDM TX Fault 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusTxFault"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49177",
                    "sensor_index": "ddmStatusTemperature.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Temperature 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 50,
                    "sensor_limit": 80,
                    "sensor_limit_warn": 75,
                    "sensor_limit_low": -10,
                    "sensor_limit_low_warn": -5,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49178",
                    "sensor_index": "ddmStatusTemperature.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Temperature 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 52,
                    "sensor_limit": 80,
                    "sensor_limit_warn": 75,
                    "sensor_limit_low": -10,
                    "sensor_limit_low_warn": -5,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "voltage",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49177",
                    "sensor_index": "ddmStatusVoltage.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Voltage 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3.4162,
                    "sensor_limit": 3.6,
                    "sensor_limit_warn": 3.5,
                    "sensor_limit_low": 3,
                    "sensor_limit_low_warn": 3.1,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "voltage",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49178",
                    "sensor_index": "ddmStatusVoltage.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Voltage 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3.385,
                    "sensor_limit": 3.6,
                    "sensor_limit_warn": 3.5,
                    "sensor_limit_low": 3,
                    "sensor_limit_low_warn": 3.1,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                }
            ],
            "state_indexes": [
                {
                    "state_name": "ddmStatusDataReady",
                    "state_descr": "False",
                    "state_value": 0,
                    "state_generic_value": 0
                },
                {
                    "state_name": "ddmStatusDataReady",
                    "state_descr": "True",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusDataReady",
                    "state_descr": "N/A",
                    "state_value": 2,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusLossSignal",
                    "state_descr": "False",
                    "state_value": 0,
                    "state_generic_value": 0
                },
                {
                    "state_name": "ddmStatusLossSignal",
                    "state_descr": "True",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusLossSignal",
                    "state_descr": "N/A",
                    "state_value": 2,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusTxFault",
                    "state_descr": "False",
                    "state_value": 0,
                    "state_generic_value": 0
                },
                {
                    "state_name": "ddmStatusTxFault",
                    "state_descr": "True",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusTxFault",
                    "state_descr": "N/A",
                    "state_value": 2,
                    "state_generic_value": 2
                }
            ]
        },
        "poller": {
            "sensors": [
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49177",
                    "sensor_index": "ddmStatusBiasCurrent.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Bias Current 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.009568,
                    "sensor_limit": 0.015,
                    "sensor_limit_warn": 0.013,
                    "sensor_limit_low": 0.001,
                    "sensor_limit_low_warn": 0.002,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49178",
                    "sensor_index": "ddmStatusBiasCurrent.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Bias Current 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.009176,
                    "sensor_limit": 0.015,
                    "sensor_limit_warn": 0.013,
                    "sensor_limit_low": 0.001,
                    "sensor_limit_low_warn": 0.002,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49177",
                    "sensor_index": "ddmStatusRxPow.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM RX Power 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -5.9998036493484,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -28.538719643218,
                    "sensor_limit_low_warn": -26.98970004336,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": -5.9998036493484,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49178",
                    "sensor_index": "ddmStatusRxPow.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM RX Power 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -5.9998036493484,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -28.538719643218,
                    "sensor_limit_low_warn": -26.98970004336,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": -5.9998036493484,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49177",
                    "sensor_index": "ddmStatusTxPow.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM TX Power 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -4.0011692792631,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -11.999706407559,
                    "sensor_limit_low_warn": -11.001794975729,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": -4.0011692792631,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49178",
                    "sensor_index": "ddmStatusTxPow.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM TX Power 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": -3.9902710431325,
                    "sensor_limit": 0,
                    "sensor_limit_warn": -1.0001543745061,
                    "sensor_limit_low": -11.999706407559,
                    "sensor_limit_low_warn": -11.001794975729,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": -3.9902710431325,
                    "user_func": "mw_to_dbm",
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49177",
                    "sensor_index": "49177",
                    "sensor_type": "ddmStatusDataReady",
                    "sensor_descr": "DDM Data Ready 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusDataReady"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49178",
                    "sensor_index": "49178",
                    "sensor_type": "ddmStatusDataReady",
                    "sensor_descr": "DDM Data Ready 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusDataReady"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49177",
                    "sensor_index": "49177",
                    "sensor_type": "ddmStatusLossSignal",
                    "sensor_descr": "DDM Loss of Signal 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusLossSignal"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49178",
                    "sensor_index": "49178",
                    "sensor_type": "ddmStatusLossSignal",
                    "sensor_descr": "DDM Loss of Signal 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusLossSignal"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49177",
                    "sensor_index": "49177",
                    "sensor_type": "ddmStatusTxFault",
                    "sensor_descr": "DDM TX Fault 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusTxFault"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49178",
                    "sensor_index": "49178",
                    "sensor_type": "ddmStatusTxFault",
                    "sensor_descr": "DDM TX Fault 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "ddmStatusTxFault"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49177",
                    "sensor_index": "ddmStatusTemperature.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Temperature 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 50,
                    "sensor_limit": 80,
                    "sensor_limit_warn": 75,
                    "sensor_limit_low": -10,
                    "sensor_limit_low_warn": -5,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49178",
                    "sensor_index": "ddmStatusTemperature.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Temperature 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 52,
                    "sensor_limit": 80,
                    "sensor_limit_warn": 75,
                    "sensor_limit_low": -10,
                    "sensor_limit_low_warn": -5,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "voltage",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49177",
                    "sensor_index": "ddmStatusVoltage.49177",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Voltage 1/0/25",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3.4162,
                    "sensor_limit": 3.6,
                    "sensor_limit_warn": 3.5,
                    "sensor_limit_low": 3,
                    "sensor_limit_low_warn": 3.1,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49177",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "voltage",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49178",
                    "sensor_index": "ddmStatusVoltage.49178",
                    "sensor_type": "jetstream",
                    "sensor_descr": "DDM Voltage 1/0/26",
                    "group": "SFPs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3.385,
                    "sensor_limit": 3.6,
                    "sensor_limit_warn": 3.5,
                    "sensor_limit_low": 3,
                    "sensor_limit_low_warn": 3.1,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "49178",
                    "entPhysicalIndex_measured": "ports",
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                }
            ],
            "state_indexes": [
                {
                    "state_name": "ddmStatusDataReady",
                    "state_descr": "False",
                    "state_value": 0,
                    "state_generic_value": 0
                },
                {
                    "state_name": "ddmStatusDataReady",
                    "state_descr": "True",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusDataReady",
                    "state_descr": "N/A",
                    "state_value": 2,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusLossSignal",
                    "state_descr": "False",
                    "state_value": 0,
                    "state_generic_value": 0
                },
                {
                    "state_name": "ddmStatusLossSignal",
                    "state_descr": "True",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusLossSignal",
                    "state_descr": "N/A",
                    "state_value": 2,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusTxFault",
                    "state_descr": "False",
                    "state_value": 0,
                    "state_generic_value": 0
                },
                {
                    "state_name": "ddmStatusTxFault",
                    "state_descr": "True",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "ddmStatusTxFault",
                    "state_descr": "N/A",
                    "state_value": 2,
                    "state_generic_value": 2
                }
            ]
        }
    }
}