    "os": {
        "discovery": {
            "devices": [
                {
                    "sysName": "<private>",
                    "sysObjectID": ".1.3.6.1.4.1.35616.2.1.1",
                    "sysDescr": "Lambdatrail-HS / xWDM Multiplexer",
                    "sysContact": "<private>",
                    "version": null,
                    "hardware": null,
                    "features": null,
                    "location": "<private>",
                    "os": "lambdatrail",
                    "type": "network",
                    "serial": null,
                    "icon": "lambdatrail.svg"
                }
            ]
        },
        "poller": "matches discovery"
    },
    "sensors": {
        "discovery": {
            "sensors": [
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.16.2",
                    "sensor_index": "portClientRxPower.2",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 2 Rx",
                    "group": "Client 2",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -0.001,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.16.3",
                    "sensor_index": "portClientRxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 3 Rx",
                    "group": "Client 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -3.798,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.16.4",
                    "sensor_index": "portClientRxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 4 Rx",
                    "group": "Client 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -4.45,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.15.3",
                    "sensor_index": "portClientTxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 3 Tx",
                    "group": "Client 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -0.77,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.15.4",
                    "sensor_index": "portClientTxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 4 Tx",
                    "group": "Client 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -2.344,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.9.2",
                    "sensor_index": "portLineRxPower.2",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 2 Rx",
                    "group": "Line 2",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -40,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.9.3",
                    "sensor_index": "portLineRxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 3 Rx",
                    "group": "Line 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -5.05,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.9.4",
                    "sensor_index": "portLineRxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 4 Rx",
                    "group": "Line 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -8.063,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.8.2",
                    "sensor_index": "portLineTxPower.2",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 2 Tx",
                    "group": "Line 2",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -1.756,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.8.3",
                    "sensor_index": "portLineTxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 3 Tx",
                    "group": "Line 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.661,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.8.4",
                    "sensor_index": "portLineTxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 4 Tx",
                    "group": "Line 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -1.79,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.4.0",
                    "sensor_index": "0",
                    "sensor_type": "systemFan1",
                    "sensor_descr": "Fan Status",
                    "group": "Fan",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemFan1"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.5.0",
                    "sensor_index": "0",
                    "sensor_type": "systemFan2",
                    "sensor_descr": "Fan Status",
                    "group": "Fan",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemFan2"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.3.0",
                    "sensor_index": "0",
                    "sensor_type": "systemPower1",
                    "sensor_descr": "Power1",
                    "group": "Power",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemPower1"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.3.0",
                    "sensor_index": "0",
                    "sensor_type": "systemPower2",
                    "sensor_descr": "Power2",
                    "group": "Power",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemPower2"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.1.0",
                    "sensor_index": "0",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Chassis Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 34,
                    "sensor_limit": 54,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 24,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.17.3",
                    "sensor_index": "portClientLaserTemp.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 3 Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 26,
                    "sensor_limit": 46,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 16,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.17.4",
                    "sensor_index": "portClientLaserTemp.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 4 Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 26,
                    "sensor_limit": 46,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 16,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                }
            ],
            "state_indexes": [
                {
                    "state_name": "systemFan1",
                    "state_descr": "failed",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan1",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan1",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan2",
                    "state_descr": "failed",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan2",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan2",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower1",
                    "state_descr": "notplugged",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower1",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower1",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower2",
                    "state_descr": "notplugged",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower2",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower2",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                }
            ]
        },
        "poller": {
            "sensors": [
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.16.2",
                    "sensor_index": "portClientRxPower.2",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 2 Rx",
                    "group": "Client 2",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -0.001,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.16.3",
                    "sensor_index": "portClientRxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 3 Rx",
                    "group": "Client 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -3.798,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.16.4",
                    "sensor_index": "portClientRxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 4 Rx",
                    "group": "Client 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -4.45,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.15.3",
                    "sensor_index": "portClientTxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 3 Tx",
                    "group": "Client 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -0.77,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.15.4",
                    "sensor_index": "portClientTxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 4 Tx",
                    "group": "Client 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -2.344,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.9.2",
                    "sensor_index": "portLineRxPower.2",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 2 Rx",
                    "group": "Line 2",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -40,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.9.3",
                    "sensor_index": "portLineRxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 3 Rx",
                    "group": "Line 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -5.05,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.9.4",
                    "sensor_index": "portLineRxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 4 Rx",
                    "group": "Line 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -8.063,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.8.2",
                    "sensor_index": "portLineTxPower.2",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 2 Tx",
                    "group": "Line 2",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -1.756,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.8.3",
                    "sensor_index": "portLineTxPower.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 3 Tx",
                    "group": "Line 3",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.661,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "dbm",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.8.4",
                    "sensor_index": "portLineTxPower.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Line 4 Tx",
                    "group": "Line 4",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": -1.79,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.4.0",
                    "sensor_index": "0",
                    "sensor_type": "systemFan1",
                    "sensor_descr": "Fan Status",
                    "group": "Fan",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemFan1"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.5.0",
                    "sensor_index": "0",
                    "sensor_type": "systemFan2",
                    "sensor_descr": "Fan Status",
                    "group": "Fan",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": 3,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemFan2"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.3.0",
                    "sensor_index": "0",
                    "sensor_type": "systemPower1",
                    "sensor_descr": "Power1",
                    "group": "Power",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemPower1"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.3.0",
                    "sensor_index": "0",
                    "sensor_type": "systemPower2",
                    "sensor_descr": "Power2",
                    "group": "Power",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "systemPower2"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.1.0",
                    "sensor_index": "0",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Chassis Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 34,
                    "sensor_limit": 54,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 24,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.17.3",
                    "sensor_index": "portClientLaserTemp.3",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 3 Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 26,
                    "sensor_limit": 46,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 16,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.35616.2.1.1.12.1.17.4",
                    "sensor_index": "portClientLaserTemp.4",
                    "sensor_type": "lambdatrail",
                    "sensor_descr": "Client 4 Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 26,
                    "sensor_limit": 46,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 16,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                }
            ],
            "state_indexes": [
                {
                    "state_name": "systemFan1",
                    "state_descr": "failed",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan1",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan1",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan2",
                    "state_descr": "failed",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan2",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemFan2",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower1",
                    "state_descr": "notplugged",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower1",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower1",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower2",
                    "state_descr": "notplugged",
                    "state_value": 1,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower2",
                    "state_descr": "Off",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "systemPower2",
                    "state_descr": "On",
                    "state_value": 3,
                    "state_generic_value": 0
                }
            ]
        }
    }
}