    "os": {
        "discovery": {
            "devices": [
                {
                    "sysName": "<private>",
                    "sysObjectID": ".1.3.6.1.4.1.3052.23.3.2",
                    "sysDescr": "SiteBoss 360 2.12.540 STD",
                    "sysContact": "<private>",
                    "version": "2.12.540 STD",
                    "hardware": "SiteBoss 360",
                    "features": null,
                    "location": "<private>",
                    "os": "siteboss360",
                    "type": "server",
                    "serial": null,
                    "icon": "siteboss.png"
                }
            ]
        },
        "poller": "matches discovery"
    },
    "sensors": {
        "discovery": {
            "sensors": [
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.11.5.1",
                    "sensor_index": "11.5.1",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "DC Voltage",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 54,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.11.5.2",
                    "sensor_index": "11.5.2",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "DC Current",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 3.9,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.11.5.3",
                    "sensor_index": "11.5.3",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "AC Input Voltage",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 243.4,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.11.5.4",
                    "sensor_index": "11.5.4",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Total Rectifers",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 4,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.11.5.5",
                    "sensor_index": "11.5.5",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Failed Rectifers",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 4,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.1",
                    "sensor_index": "12.5.1",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Fuel Level",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 89,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.10",
                    "sensor_index": "12.5.10",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen O2 Sensor",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.1,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.11",
                    "sensor_index": "12.5.11",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Current Phs A",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.12",
                    "sensor_index": "12.5.12",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Current Phs B",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.13",
                    "sensor_index": "12.5.13",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Current Phs C",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.14",
                    "sensor_index": "12.5.14",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Aveg Current",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.15",
                    "sensor_index": "12.5.15",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Voltage Phs A-B",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.16",
                    "sensor_index": "12.5.16",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Voltage Phs B-C",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.17",
                    "sensor_index": "12.5.17",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Voltage Phs C-A",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.18",
                    "sensor_index": "12.5.18",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Aveg Voltage",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.19",
                    "sensor_index": "12.5.19",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Power KW",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.2",
                    "sensor_index": "12.5.2",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen RPM",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.20",
                    "sensor_index": "12.5.20",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Total PF",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 100,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.21",
                    "sensor_index": "12.5.21",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Frequency",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.3",
                    "sensor_index": "12.5.3",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Coolant Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 93,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.4",
                    "sensor_index": "12.5.4",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Battery Voltage",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 26.3,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.5",
                    "sensor_index": "12.5.5",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Run Hours",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 258.4,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.6",
                    "sensor_index": "12.5.6",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Oil Pressure",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.7",
                    "sensor_index": "12.5.7",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Oil Temp",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.8",
                    "sensor_index": "12.5.8",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Coolant Level",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 62.5,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "count",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.12.5.9",
                    "sensor_index": "12.5.9",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Gen Throt Pos",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "humidity",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.6.1.3.1",
                    "sensor_index": "1.3.1",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Humidity",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 49,
                    "sensor_limit": 70,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 30,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "percent",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.6.1.1.7.1",
                    "sensor_index": "1",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Fuel Level",
                    "group": null,
                    "sensor_divisor": 100,
                    "sensor_multiplier": 1,
                    "sensor_current": 88.99,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 10,
                    "sensor_limit_low_warn": 20,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.1",
                    "sensor_index": "11.2.1",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "AC Fail",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.2",
                    "sensor_index": "11.2.2",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Battery on Discharge",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.3",
                    "sensor_index": "11.2.3",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Battery Breaker Trip",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.4",
                    "sensor_index": "11.2.4",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Dist Breaker Trip",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.5",
                    "sensor_index": "11.2.5",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Rectifier Fail",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.6",
                    "sensor_index": "11.2.6",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Reserve Time Low",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.7",
                    "sensor_index": "11.2.7",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "High Battery Temp",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.11.2.8",
                    "sensor_index": "11.2.8",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Battery Test Active",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.1",
                    "sensor_index": "200.2.1",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Door Sensor",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.16",
                    "sensor_index": "200.2.16",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "USAF Door",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.2",
                    "sensor_index": "200.2.2",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "High Temp",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.3",
                    "sensor_index": "200.2.3",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Low Temp",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.4",
                    "sensor_index": "200.2.4",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Smoke Detector",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.5",
                    "sensor_index": "200.2.5",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Commercial Power",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.6",
                    "sensor_index": "200.2.6",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "A/C Surge Arrestor Fail",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.7",
                    "sensor_index": "200.2.7",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "HVAC",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.5.200.2.8",
                    "sensor_index": "200.2.8",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Generator A/C Sensor",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.23.1.1.1.1.7.1.1.1",
                    "sensor_index": "1.1.1",
                    "sensor_type": "siteboss360",
                    "sensor_descr": "Temperature",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 21.11,
                    "sensor_limit": 41.11,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 11.11,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": "fahrenheit_to_celsius",
                    "rrd_type": "GAUGE",
                    "state_name": null
                }
            ],
            "state_indexes": [
                {
                    "state_name": "contactClosure",
                    "state_descr": "event",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "contactClosure",
                    "state_descr": "normal",
                    "state_value": 2,
                    "state_generic_value": 0
                }
            ]
        },
        "poller": "matches discovery"
    }
}