    "os": {
        "discovery": {
            "devices": [
                {
                    "sysName": "<private>",
                    "sysObjectID": ".1.3.6.1.4.1.3052.20.3.2",
                    "sysDescr": "SiteBoss 572 2.12.570 STD",
                    "sysContact": "<private>",
                    "version": "2.12.570 STD",
                    "hardware": "SiteBoss 572",
                    "features": null,
                    "location": "LAB01-SB01",
                    "os": "siteboss572",
                    "type": "power",
                    "serial": "572010470",
                    "icon": "siteboss.png"
                }
            ]
        },
        "poller": "matches discovery"
    },
    "sensors": {
        "discovery": {
            "sensors": [
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.5.200.1",
                    "sensor_index": "pdnMainCurrentValue.200.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Module: 200.1",
                    "group": "Current (Per Module)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.25,
                    "sensor_limit": 16,
                    "sensor_limit_warn": 15,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "200",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.5.4.1",
                    "sensor_index": "pdnMainCurrentValue.4.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Module: 4.1",
                    "group": "Current (Per Module)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0.25,
                    "sensor_limit": 16,
                    "sensor_limit_warn": 15,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "4",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.200.1",
                    "sensor_index": "pdnOutputCurrentValue.200.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 200.1",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "200",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.200.2",
                    "sensor_index": "pdnOutputCurrentValue.200.2",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 200.2",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "200",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.200.3",
                    "sensor_index": "pdnOutputCurrentValue.200.3",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 200.3",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "200",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.200.4",
                    "sensor_index": "pdnOutputCurrentValue.200.4",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 200.4",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "200",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.200.5",
                    "sensor_index": "pdnOutputCurrentValue.200.5",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 200.5",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "200",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.4.1",
                    "sensor_index": "pdnOutputCurrentValue.4.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 4.1",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "4",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.4.2",
                    "sensor_index": "pdnOutputCurrentValue.4.2",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 4.2",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "4",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.4.3",
                    "sensor_index": "pdnOutputCurrentValue.4.3",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 4.3",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "4",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.4.4",
                    "sensor_index": "pdnOutputCurrentValue.4.4",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 4.4",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "4",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "current",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.23.4.5",
                    "sensor_index": "pdnOutputCurrentValue.4.5",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Port: 4.5",
                    "group": "Current (Per Port)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 0,
                    "sensor_limit": 12,
                    "sensor_limit_warn": 10,
                    "sensor_limit_low": 0,
                    "sensor_limit_low_warn": 0.15,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": "4",
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "humidity",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.6.3.3.1",
                    "sensor_index": "3.3.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Sensor: 3.3.1 | Humidity",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 28,
                    "sensor_limit": 70,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 30,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "power",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.20.200.1",
                    "sensor_index": "200.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Module: 200.1",
                    "group": "Power (Per Module)",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 13,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "power",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.20.4.1",
                    "sensor_index": "4.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Module: 4.1",
                    "group": "Power (Per Module)",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 13,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.5.200.2.1",
                    "sensor_index": "200.2.1",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Contact: 200.2.1 | Front Door",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.5.200.2.2",
                    "sensor_index": "200.2.2",
                    "sensor_type": "contactClosure",
                    "sensor_descr": "Contact: 200.2.2 | Back Door",
                    "group": "Contact Closures",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 2,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "contactClosure"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.6.200.6.1",
                    "sensor_index": "200.6.1",
                    "sensor_type": "powerOutput",
                    "sensor_descr": "Port: 200.6.1 |",
                    "group": "Power Outputs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 1,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "powerOutput"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.6.200.6.2",
                    "sensor_index": "200.6.2",
                    "sensor_type": "powerOutput",
                    "sensor_descr": "Port: 200.6.2 |",
                    "group": "Power Outputs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 1,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "powerOutput"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.6.200.6.3",
                    "sensor_index": "200.6.3",
                    "sensor_type": "powerOutput",
                    "sensor_descr": "Port: 200.6.3 |",
                    "group": "Power Outputs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 1,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "powerOutput"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.6.200.6.4",
                    "sensor_index": "200.6.4",
                    "sensor_type": "powerOutput",
                    "sensor_descr": "Port: 200.6.4 |",
                    "group": "Power Outputs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 1,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "powerOutput"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "state",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.6.200.6.5",
                    "sensor_index": "200.6.5",
                    "sensor_type": "powerOutput",
                    "sensor_descr": "Port: 200.6.5 |",
                    "group": "Power Outputs",
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 1,
                    "sensor_limit": null,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": null,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": "powerOutput"
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.7.200.1.1",
                    "sensor_index": "200.1.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Sensor: 200.1.1 | Temperature",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 37,
                    "sensor_limit": 57,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 27,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "temperature",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.1.1.1.7.3.1.1",
                    "sensor_index": "3.1.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Sensor: 3.1.1 | Temperature",
                    "group": null,
                    "sensor_divisor": 1,
                    "sensor_multiplier": 1,
                    "sensor_current": 30,
                    "sensor_limit": 50,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 20,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "voltage",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.13.200.1",
                    "sensor_index": "200.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Module: 200.1",
                    "group": "Voltage (Per Module)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 53.359,
                    "sensor_limit": 61.36285,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 45.35515,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                },
                {
                    "sensor_deleted": 0,
                    "sensor_class": "voltage",
                    "poller_type": "snmp",
                    "sensor_oid": ".1.3.6.1.4.1.3052.20.1.5.4.1.1.13.4.1",
                    "sensor_index": "4.1",
                    "sensor_type": "siteboss572",
                    "sensor_descr": "Module: 4.1",
                    "group": "Voltage (Per Module)",
                    "sensor_divisor": 1000,
                    "sensor_multiplier": 1,
                    "sensor_current": 52.537,
                    "sensor_limit": 60.41755,
                    "sensor_limit_warn": null,
                    "sensor_limit_low": 44.65645,
                    "sensor_limit_low_warn": null,
                    "sensor_alert": 1,
                    "sensor_custom": "No",
                    "entPhysicalIndex": null,
                    "entPhysicalIndex_measured": null,
                    "sensor_prev": null,
                    "user_func": null,
                    "rrd_type": "GAUGE",
                    "state_name": null
                }
            ],
            "state_indexes": [
                {
                    "state_name": "contactClosure",
                    "state_descr": "Open",
                    "state_value": 1,
                    "state_generic_value": 2
                },
                {
                    "state_name": "contactClosure",
                    "state_descr": "Closed",
                    "state_value": 2,
                    "state_generic_value": 0
                },
                {
                    "state_name": "powerOutput",
                    "state_descr": "de-energized",
                    "state_value": 0,
                    "state_generic_value": 1
                },
                {
                    "state_name": "powerOutput",
                    "state_descr": "energized",
                    "state_value": 1,
                    "state_generic_value": 0
                }
            ]
        },
        "poller": "matches discovery"
    }
}